Siemens 6AV7611-0AF12-0AJ0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF12-0AJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial-grade panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and machine control.
The SIMATIC Panel PC 670 6AV7611-0AF12-0AJ0 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation for intuitive operator interaction. The unit is built around an x86-compatible processor architecture and is designed to run Windows-based operating systems, supporting SIMATIC WinCC and other Siemens visualization software. It provides standard industrial communication interfaces including Ethernet and serial ports, and is designed with a fanless or low-maintenance cooling concept suited to continuous industrial operation. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in the automotive, food and beverage, pharmaceutical, and general manufacturing industries. It is typically installed in control cabinets or operator panels on production lines where a combination of PC functionality and HMI visualization is required. Its compatibility with Siemens SIMATIC software and standard PC peripherals makes it suitable for SCADA, data logging, recipe management, and process visualization applications.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front panel) |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 95% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Operating System | Windows XP / Windows CE compatible |
| Series/Product Family | SIMATIC Panel PC 670 |
| Mounting | Panel mounting |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration. Replace storage medium if faulty. - Event ID: 200
- Watchdog timeout triggered — application software stopped responding within the defined monitoring interval.
Restart the application. Check for software deadlocks or excessive CPU load. Update or reinstall the HMI runtime software if the issue persists. - Event ID: 300
- Communication connection to PLC lost or Ethernet link failure detected.
Check Ethernet cable and network switch connections. Verify IP address configuration and PLC communication settings in WinCC or the configured HMI project. - Event ID: 400
- Touchscreen calibration error — touch input coordinates are misaligned or unresponsive.
Perform touchscreen recalibration via the Windows control panel or SIMATIC touch calibration utility. Clean the touch surface and check for physical damage. - Event ID: 500
- Internal temperature warning — panel PC internal temperature has exceeded the recommended operating threshold.
Check ambient temperature and ensure adequate ventilation around the unit. Clean air vents or filters if present. Verify that the unit is not installed in a location exceeding 45 °C. - Event ID: 600
- Power supply undervoltage detected — supply voltage dropped below the minimum 24 V DC operating threshold.
Measure the DC supply voltage at the power connector. Ensure the power supply unit is rated correctly and check for loose or corroded connections. - Event ID: 700
- Storage medium error — read/write failure on the internal hard disk or CompactFlash card.
Back up data immediately if possible. Run a disk check utility. Replace the CompactFlash card or hard disk drive with a compatible replacement and restore the OS and application.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AF12-0AJ0?
The SIMATIC Panel PC 670 6AV7611-0AF12-0AJ0 operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What display size and resolution does this Panel PC have?
This unit features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA), suitable for detailed process visualization.
Is this Panel PC compatible with Siemens WinCC software?
Yes, the SIMATIC Panel PC 670 is designed to run Siemens SIMATIC WinCC and other Windows-based HMI and SCADA software packages.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AF12-0AJ0 meets IP65 protection, providing full dust protection and resistance to water jets.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), RS-232 serial, and USB interfaces, enabling connectivity to PLCs, networks, and peripheral devices.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator is active. Inspect internal fuses if accessible.
Restore correct supply voltage if out of range. Replace any blown internal fuse with the correct rated replacement. If the backlight is faulty, the display panel or inverter board may require replacement.
Touchscreen does not respond or registers incorrect touch positions
Attempt to operate the unit using a connected USB mouse or keyboard to determine if the issue is isolated to the touch layer. Check for physical damage or contamination on the touch surface.
Recalibrate the touchscreen using the Windows control panel or the SIMATIC calibration tool. Clean the touch surface with a soft, dry cloth. If recalibration fails, the touch controller or touch overlay may need replacement.
Panel PC fails to boot or shows OS startup errors
Connect an external monitor if possible to observe BIOS or POST error messages. Check the CompactFlash card or hard disk for secure seating and physical damage.
Reseat the storage medium. If the OS is corrupted, restore from a backup image or reinstall the operating system and HMI application software onto a replacement storage device.
Communication with PLC is lost intermittently or permanently
Check Ethernet cable integrity and verify the network switch or hub is functioning. Use a laptop to ping the Panel PC IP address and confirm network connectivity. Review WinCC or HMI project communication settings.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings if there is an address conflict. Update the communication driver or HMI project configuration to match the PLC settings.
Unit overheats and shuts down unexpectedly
Measure the ambient temperature at the installation location. Inspect the panel cutout and enclosure for adequate ventilation. Check that no heat sources are located directly adjacent to the unit.
Ensure the installation environment does not exceed 45 °C. Improve enclosure ventilation or add forced air cooling. Clean any dust accumulation from vents or the rear of the unit.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177
€ 1.247,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page