Siemens 6AV7611-0AF12-0AE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AF12-0AE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a built-in display with a full PC architecture, enabling both operator control and data processing within a single integrated device.
The SIMATIC Panel PC 670 (6AV7611-0AF12-0AE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touch-sensitive front panel for operator interaction. It is based on an x86-compatible processor architecture and supports standard PC operating systems such as Windows XP Embedded or Windows 2000, allowing integration with standard SCADA and HMI software packages including WinCC and WinCC flexible. The unit provides communication interfaces including Ethernet (RJ45) and serial ports, and is designed with a fanless or low-maintenance cooling concept suited to industrial operation. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine tool applications where a robust, panel-integrated PC solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its compatibility with Siemens SIMATIC software and standard PC peripherals makes it a practical choice for visualization, data logging, and process monitoring tasks.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| IP Protection Rating (Front) | IP65 |
| Input/Operating Voltage | 24 V DC |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Operating System | Windows XP Embedded / Windows 2000 |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup error – the operating system failed to boot correctly, possibly due to corrupted system files or a failed storage medium.
Check the CompactFlash card or hard disk for errors. Reinstall or restore the operating system image if necessary. - Event ID: 1000
- Application fault – the HMI or SCADA application (e.g. WinCC) has crashed or terminated unexpectedly.
Review the Windows Event Viewer for application error details. Reinstall the HMI software or restore a known-good project backup. - Event ID: 7000
- Service failed to start – a required Windows service did not start during boot, which may prevent HMI communication or display functions.
Check the Windows Services configuration. Ensure all required SIMATIC and communication services are set to automatic startup. - Hardware Error: CMOS Battery
- CMOS battery voltage is low or depleted, causing loss of BIOS settings and real-time clock data after power cycles.
Replace the internal CMOS/RTC battery (typically CR2032). Re-enter BIOS settings and synchronize the system clock after replacement. - Communication Error: Ethernet
- Loss of Ethernet communication between the Panel PC and the PLC or SCADA server, resulting in no data updates on the display.
Check Ethernet cable connections and switch/hub status. Verify IP address configuration and network settings in the operating system. - Display Error: No Signal
- The display backlight is on but no image is shown, indicating a failure in the graphics subsystem or display connection.
Check internal display cable connections. If the fault persists, the display unit or graphics hardware may require replacement. - Watchdog Timeout
- The system watchdog timer has triggered a reset due to the application or operating system becoming unresponsive.
Investigate the cause of the system hang via event logs. Optimize the HMI application to prevent CPU overload, and ensure adequate memory is available.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AF12-0AE0?
The SIMATIC Panel PC 670 (6AV7611-0AF12-0AE0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.
What operating system does this Panel PC support?
This unit supports Windows XP Embedded and Windows 2000, allowing it to run standard HMI and SCADA software such as Siemens WinCC and WinCC flexible.
What is the front panel protection rating of this device?
The front panel of the 6AV7611-0AF12-0AE0 meets IP65 protection, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel installation.
Is this Panel PC compatible with Siemens SIMATIC S7 PLCs?
Yes, the SIMATIC Panel PC 670 can communicate with SIMATIC S7-300 and S7-400 PLCs via Ethernet (TCP/IP) or PROFIBUS, using appropriate communication drivers within WinCC or WinCC flexible.
What display size and resolution does the 6AV7611-0AF12-0AE0 have?
This unit features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), with a resistive touchscreen for operator input.
Troubleshooting
Panel PC does not boot after power on
Check the 24 V DC supply voltage at the power connector. Verify that the CompactFlash card or hard disk is properly seated and not corrupted. Listen for any BIOS POST beep codes.
Reseat the storage medium and attempt to boot again. If the storage device is faulty, replace the CompactFlash card and restore the operating system image from a backup or Siemens recovery media.
Touchscreen does not respond to input
Check whether the display is showing a correct image (ruling out a display-only fault). Verify that the touchscreen calibration has not been lost and that no protective film is obstructing the screen.
Recalibrate the touchscreen using the Windows control panel or the Siemens calibration utility. If calibration does not resolve the issue, the touchscreen overlay or controller board may need replacement.
HMI application loses communication with the PLC
Check the Ethernet or PROFIBUS cable connections at both the Panel PC and the PLC. Verify the IP address and subnet mask settings in the operating system network configuration.
Restore correct network settings and replace any damaged cables. Ensure the communication driver in WinCC is correctly configured and that the PLC is in RUN mode.
Display backlight turns off or screen goes dark during operation
Check the power management settings in Windows, which may be configured to turn off the display after a period of inactivity. Also inspect the backlight inverter for faults.
Disable display power-saving features in the Windows power management settings. If the backlight fails to illuminate even after adjusting settings, the CCFL backlight or inverter board requires replacement.
System clock resets to incorrect date and time after each power cycle
This symptom indicates a depleted CMOS battery, which is responsible for maintaining BIOS settings and the real-time clock when the main power is removed.
Open the Panel PC enclosure and replace the CMOS battery (typically a CR2032 coin cell). After replacement, re-enter the correct date, time, and any modified BIOS settings.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page