Siemens 6AV7611-0AE30-0BJ0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE30-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates computing hardware and a display into a single ruggedized enclosure suitable for direct panel mounting.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP or Windows XP Embedded, providing compatibility with standard SCADA and HMI software packages including WinCC and WinCC flexible. The unit provides communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is built to withstand industrial environments with a front panel protection rating of IP65.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a full PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and general factory automation. Its panel-mount design and industrial-grade construction make it appropriate for integration into control cabinets and operator stations where reliable long-term visualization and control are required.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Processor | Intel Celeron |
| Operating System | Windows XP / Windows XP Embedded |
| Communication Interface | Ethernet RJ45, USB, RS-232 (serial) |
| Front Panel Protection Rating | IP65 |
| Mounting | Panel mounting |
| Input/Operating Voltage | 24 V DC |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check hard disk or CompactFlash card integrity. Verify BIOS settings and reseat storage media. Replace storage device if corrupted. - Event ID: 200
- Watchdog timeout triggered, indicating the application software has stopped responding.
Restart the Panel PC. Check the HMI application for software errors or infinite loops. Update or reinstall the HMI runtime software. - Event ID: 300
- Ethernet communication link failure or network interface not detected.
Check Ethernet cable connection and network switch. Verify IP address configuration in Windows network settings. Replace cable or network adapter if faulty. - Event ID: 400
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen via the Windows control panel or SIMATIC touchscreen calibration utility. Clean the screen surface and check for physical damage. - Event ID: 500
- Internal temperature warning — operating temperature threshold exceeded.
Check ambient temperature around the panel. Ensure ventilation slots are not blocked. Verify cooling fan operation if fitted. Reduce ambient temperature or improve cabinet ventilation. - Event ID: 600
- Power supply voltage out of range — 24 V DC supply below or above acceptable limits.
Measure the 24 V DC supply at the power input connector. Ensure supply is within the specified tolerance. Replace or adjust the power supply unit as needed. - Event ID: 700
- USB device error — connected USB peripheral not recognized or communication failure.
Disconnect and reconnect the USB device. Try an alternative USB port. Check device driver installation in Windows Device Manager. - Event ID: 800
- Hard disk or CompactFlash storage device read/write error.
Run a disk check utility (chkdsk) on the storage device. Back up data and replace the storage device if errors persist. Restore the operating system image if required.
Frequently Asked Questions
What operating system does the SIMATIC Panel PC 670 (6AV7611-0AE30-0BJ0) run?
This unit runs Microsoft Windows XP or Windows XP Embedded, providing compatibility with standard industrial HMI and SCADA software packages such as Siemens WinCC and WinCC flexible.
What is the display size and resolution of this Panel PC?
The 6AV7611-0AE30-0BJ0 features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen interface.
What is the supply voltage for this Panel PC?
The unit operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.
What communication interfaces are available on this unit?
The Panel PC 670 provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces, enabling connectivity to PLCs, networks, and peripheral devices.
Is this Panel PC compatible with Siemens WinCC software?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC and WinCC flexible HMI software, as well as other standard Windows-based SCADA and visualization applications.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power input connector. Verify that the power LED indicator is active. Measure internal fuse continuity if accessible.
Restore the 24 V DC supply to within specification. Replace the internal fuse if blown. If the display backlight has failed, replace the backlight inverter or the display assembly.
Touchscreen does not respond or registers incorrect touch positions
Determine whether the issue is a calibration error or a hardware failure by attempting touchscreen calibration via the Windows control panel. Check for physical damage or contamination on the screen surface.
Recalibrate the touchscreen using the SIMATIC or Windows calibration utility. Clean the screen surface. If calibration fails repeatedly, replace the touchscreen overlay or the display assembly.
Panel PC fails to boot or freezes during startup
Check the CompactFlash card or hard disk for errors using a disk check utility. Verify that the operating system image is intact. Check for corrupted startup files in Windows.
Run chkdsk on the storage device. Restore the factory operating system image from a backup. Replace the CompactFlash card or hard disk if the storage device is faulty.
Ethernet communication not working
Verify the Ethernet cable connection and check the link LED on the RJ45 port. Confirm IP address settings in Windows network configuration. Test connectivity with a ping command.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings to match the network. Update or reinstall the network adapter driver in Windows Device Manager if the interface is not detected.
Unit shuts down unexpectedly or triggers a watchdog reset
Check the ambient temperature around the panel and verify that ventilation is not obstructed. Review the Windows event log for application errors or watchdog timeout events.
Improve cabinet ventilation or reduce ambient temperature. Investigate and resolve any software application errors causing the watchdog timeout. Update the HMI runtime software if instability persists.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page