Siemens 6AV7611-0AE30-0BG0 SIMATIC Mobile Panel 170
€ 1.770,00
The Siemens 6AV7611-0AE30-0BG0 is a mobile operator panel belonging to the SIMATIC Mobile Panel 170 series, designed for flexible, handheld human-machine interface applications in industrial environments. This unit provides operators with a portable touchscreen interface that can be carried directly to the point of operation, enabling on-site monitoring and control of machinery and processes. It is part of Siemens' broader SIMATIC HMI product range and is engineered for demanding industrial use.
The Mobile Panel 170 features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA), supporting up to 256 colors for clear visualization of process data and graphics. It is equipped with a resistive touchscreen and a membrane keypad with configurable function keys for flexible operator input. The panel communicates via PROFIBUS DP and MPI interfaces, allowing direct integration with Siemens S7-300 and S7-400 PLCs. An integrated enabling button and emergency stop button are included for safety-critical applications, and the unit operates from a 24 V DC supply. Configuration is performed using Siemens WinCC flexible software.
The SIMATIC Mobile Panel 170 is widely used in manufacturing, automotive assembly, machine tool, and process industries where operators need to move freely around large machines or production lines. Its handheld form factor makes it particularly suitable for setup, commissioning, and maintenance tasks on presses, transfer lines, and robotic cells. The integrated safety features, including the enabling device and emergency stop, make it compliant with safety requirements for operator panels used in close proximity to moving machinery.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Resolution | 320 x 240 pixels (QVGA) |
| Display Colors | 256 colors |
| Display Type | STN color LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Communication Interface | PROFIBUS DP, MPI |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front) |
| Safety Features | Integrated enabling button, emergency stop button |
| Configuration Software | WinCC flexible |
| Series/Product Family | SIMATIC Mobile Panel 170 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between the Mobile Panel and the connected PLC via MPI or PROFIBUS DP. The connection has been interrupted or cannot be established.
Check the PROFIBUS/MPI cable connections and termination resistors. Verify the PLC is powered and running. Confirm the configured station address matches the PLC settings in WinCC flexible. - Event ID: 10001
- Connection to the configured PLC partner has been lost during operation.
Inspect the cable for damage or loose connectors. Check for address conflicts on the bus. Restart the panel and PLC if the connection is not re-established automatically. - Event ID: 20000
- Project download error. The project could not be transferred to the Mobile Panel.
Verify the transfer cable connection and that the panel is in transfer mode. Check that the WinCC flexible project is compiled without errors before attempting the download again. - Event ID: 40000
- System memory low. The available memory on the panel is insufficient to load the current project.
Reduce the project size by optimizing graphics and screen objects. Delete unused screens or images and re-download the project to the panel. - Event ID: 50000
- Enabling button not actuated or released. The enabling device is in the released or panic position, preventing operation in safety-relevant mode.
Ensure the operator is correctly holding the enabling button in the intermediate (enabled) position. Check the enabling button for mechanical damage or wear and replace if defective. - Event ID: 60000
- Emergency stop activated. The integrated emergency stop button has been pressed.
Identify and resolve the cause of the emergency stop activation. Unlock the emergency stop button by rotating it, then reset the safety circuit before resuming operation. - Event ID: 70000
- Operating system or firmware error detected on the panel.
Perform a controlled restart of the Mobile Panel. If the error persists, re-flash the panel firmware using the appropriate Siemens ProSave tool and re-download the project.
Frequently Asked Questions
Which PLCs are compatible with the SIMATIC Mobile Panel 170?
The Mobile Panel 170 is compatible with Siemens S7-300 and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It can also communicate with S7-200 PLCs via a point-to-point connection depending on configuration.
What software is used to configure and program the 6AV7611-0AE30-0BG0?
The panel is configured using Siemens WinCC flexible, which allows creation of screens, tags, and communication settings. The project is then transferred to the panel via a serial or USB-to-serial transfer cable.
Does this Mobile Panel include safety features for use near moving machinery?
Yes, the 6AV7611-0AE30-0BG0 includes an integrated enabling button (three-position device) and an emergency stop button, making it suitable for use in safety-relevant applications near moving machine parts.
What is the supply voltage required for the Mobile Panel 170?
The unit requires a 24 V DC power supply, typically provided through the connecting cable from a control cabinet power supply unit.
Can the panel be used in outdoor environments?
The panel carries an IP65 protection rating on the front face, offering protection against dust and water jets, but it is not rated for direct outdoor exposure to sunlight or extreme temperatures beyond its specified operating range of 0 °C to +50 °C.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the panel connector. Check the connecting cable for continuity and inspect for damaged pins.
Ensure the power supply is within the 24 V DC specification. Replace the connecting cable if damaged. If the supply is correct and the display remains blank, the internal backlight or power board may require repair or replacement.
Communication fault with PLC, no data displayed on screen
Check the PROFIBUS DP or MPI bus cable connections at both the panel and PLC ends. Verify bus termination is correctly applied at both ends of the network. Confirm the station address set on the panel matches the PLC configuration.
Re-seat all connectors and ensure termination resistors are active only at the physical ends of the bus. Correct any address conflicts and re-download the project if configuration changes are made.
Touchscreen does not respond or responds inaccurately
Inspect the touchscreen surface for damage, contamination, or excessive wear. Attempt a touchscreen recalibration from the panel's system settings menu.
Clean the touchscreen surface with a soft, dry cloth. Perform a recalibration procedure via the Control Panel in the panel's operating system. If inaccuracy persists after calibration, the touchscreen overlay may need replacement.
Emergency stop cannot be reset after activation
Check that the emergency stop button has been physically unlocked by rotating the button head. Inspect the safety relay or safety circuit in the control cabinet for a latched fault condition.
Rotate and release the emergency stop mushroom head to unlock it. Reset the safety circuit in the control cabinet according to the machine's safety reset procedure. If the button does not unlock mechanically, replace the emergency stop button assembly.
Project download fails or transfer is interrupted
Verify the panel is set to transfer mode before initiating the download. Check the transfer cable connection between the PC and the panel. Confirm the WinCC flexible project compiles without errors.
Switch the panel to transfer mode via the Start Center menu. Use a known-good transfer cable and ensure the correct COM port is selected in WinCC flexible. Re-compile the project and retry the transfer. If issues persist, use Siemens ProSave to restore the panel operating system before re-downloading.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page