Siemens 6AV7611-0AE22-0CJ0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE22-0CJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-performance computing platform with a robust industrial enclosure, providing a reliable operator interface for process control and machine monitoring applications.
The SIMATIC Panel PC 670 features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touch-sensitive screen for intuitive operator interaction. It is equipped with an Intel Celeron processor and runs on Microsoft Windows operating systems, supporting SIMATIC WinCC and other Siemens visualization software. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), enabling integration with PLCs, SCADA systems, and plant networks. The front panel meets IP65 protection rating, making it resistant to dust and water ingress in industrial environments.
The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, chemical processing, and food and beverage industries where a full PC-based HMI platform is required. It is suitable for applications demanding complex visualization, data logging, recipe management, and connectivity to enterprise-level systems. Its rugged construction and fanless design options make it appropriate for installation in control cabinets and operator panels in harsh industrial settings.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Communication Interfaces | Ethernet RJ45, USB, RS-232 |
| Operating System | Microsoft Windows XP Embedded |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the Panel PC failed to complete the boot sequence correctly, possibly due to a corrupted operating system or failed hardware component.
Check the boot device and operating system integrity. Restore the system image using the recovery partition or a backup image via USB. - Event ID: 1000
- Application crash — a running HMI or visualization application (e.g. WinCC) has terminated unexpectedly.
Review the Windows Event Viewer for application error details. Reinstall or repair the affected software. Check for memory or hardware faults. - Event ID: 7026
- Driver load failure — a required hardware driver failed to load during system startup.
Verify driver installation in Device Manager. Reinstall the appropriate driver package for the affected hardware component. - WinCC Runtime Error
- WinCC Runtime has encountered a configuration or communication error and cannot establish a connection to the PLC or data source.
Check the communication settings in WinCC project configuration. Verify network connectivity and PLC address settings. Restart the WinCC Runtime service. - Touchscreen Calibration Error
- The touchscreen calibration data is invalid or has been lost, causing inaccurate touch input registration.
Run the touchscreen calibration utility from the Windows Control Panel or SIMATIC settings. Recalibrate the touch panel and save the calibration data. - Temperature Warning
- The internal temperature of the Panel PC has exceeded the recommended operating threshold, triggering a thermal warning.
Check ambient temperature and ventilation around the unit. Clean any air vents or filters. Verify that the cooling system or heat spreader is functioning correctly. - Hard Disk Error
- The internal hard disk or Compact Flash storage device has reported a read/write error or is approaching failure.
Run a disk diagnostic utility (e.g. Windows CHKDSK). Back up all project data immediately and replace the storage medium if errors persist.
Frequently Asked Questions
What operating system does the 6AV7611-0AE22-0CJ0 run?
This Panel PC 670 variant runs Microsoft Windows XP Embedded, which is compatible with SIMATIC WinCC and other Siemens HMI software packages.
What is the supply voltage for this Panel PC?
The unit operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in control cabinet installations.
Is the 6AV7611-0AE22-0CJ0 compatible with SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and other PC-based Siemens visualization software, provided the correct software licenses are installed.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AE22-0CJ0 carries an IP65 protection rating, making it resistant to dust and low-pressure water jets.
Can the storage medium be replaced or upgraded?
Yes, the Panel PC 670 series supports replacement of the internal hard disk or Compact Flash card. It is recommended to use Siemens-approved storage media and to restore the system image after replacement.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is active. Measure voltage at the internal power supply output rails.
Restore correct supply voltage if out of range. If the backlight has failed, replace the inverter board or the display assembly. If the unit does not power on at all, inspect internal fuses and the power supply module.
Touchscreen does not respond or registers incorrect touch positions
Determine whether the issue is a calibration problem or a hardware failure by attempting to recalibrate via the Windows Control Panel touchscreen utility.
Recalibrate the touchscreen using the built-in calibration tool. If the problem persists after calibration, inspect the touchscreen controller connections and replace the touch panel overlay if damaged.
Panel PC fails to boot or gets stuck at startup screen
Check whether the operating system partition is intact by attempting to boot from an external USB recovery device. Listen for hard disk activity during startup.
Restore the system image from the Siemens recovery partition or a previously created backup image. If the storage device has failed, replace it with a compatible unit and reinstall the operating system and WinCC software.
Loss of communication with PLC or SCADA system
Verify the Ethernet cable connection and check the network adapter status in Windows Device Manager. Ping the PLC IP address from the Panel PC to confirm network connectivity.
Check and correct IP address configuration on both the Panel PC and the PLC. Replace the Ethernet cable if faulty. Reinstall the network adapter driver if the adapter is not recognized. Verify firewall settings are not blocking communication.
Unit overheating or shutting down unexpectedly
Check the ambient temperature around the installation. Inspect ventilation slots for blockage by dust or debris. Monitor internal temperature via the BIOS or system monitoring utility.
Clean all ventilation openings with compressed air. Ensure the installation environment does not exceed 50 °C ambient temperature. Verify that the thermal interface material between the processor and heat spreader is intact; replace if degraded.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page