• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AE22-0BG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AE22-0BG0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AE22-0BG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AE22-0BG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit integrates computing hardware and a display into a single rugged enclosure suitable for direct panel installation.

    The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs Microsoft Windows XP Professional or Windows XP Embedded, providing a familiar PC-based environment for SCADA and HMI software such as Siemens WinCC. The unit offers multiple communication interfaces including Ethernet (RJ45), USB ports, and serial interfaces (RS-232), and is built to withstand industrial conditions with a front panel protection rating of IP65.

    The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a full PC-based visualization platform is required. Its panel-mount design makes it suitable for integration into control cabinets and operator stations in industries such as automotive, food and beverage, chemical processing, and water treatment. The combination of standard PC architecture with industrial-grade construction allows it to run complex SCADA applications while withstanding the vibration, dust, and temperature variations typical of factory floor environments.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 px (XGA)
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Processor Intel Celeron
    Operating System Windows XP Professional / Windows XP Embedded
    Communication Interface Ethernet (RJ45), USB, RS-232
    Front Panel Protection Rating IP65
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Mounting Panel mount
    Certifications CE, UL
    Series/Product Family SIMATIC Panel PC 670

    Common Error Codes and System Events

    Event ID: 100
    System startup failure – the operating system failed to boot correctly, possibly due to corrupted system files or a failed storage device.
    Check the hard disk or CompactFlash card for errors. Attempt system restore or reinstall the operating system.
    Event ID: 1001
    Application crash detected – a monitored application such as WinCC has terminated unexpectedly.
    Review the Windows Event Viewer for application error details. Reinstall or update the affected software. Check for memory or hardware faults.
    Event ID: 6008
    Unexpected system shutdown – the PC was shut down uncleanly, possibly due to a power interruption or system hang.
    Verify the power supply stability. Check UPS if installed. Review event logs for preceding errors that may have caused the shutdown.
    BIOS POST Error
    Power-On Self-Test failure – hardware component not detected or failed during startup, such as RAM or storage device.
    Reseat RAM modules and storage devices. Clear CMOS if necessary. Replace faulty hardware components.
    WinCC Runtime Error
    WinCC visualization software encountered a runtime error, often related to project configuration or communication driver issues.
    Restart the WinCC runtime. Verify project configuration and communication driver settings. Reinstall WinCC if the error persists.
    Network Communication Error
    Loss of Ethernet communication between the Panel PC and connected controllers or servers.
    Check Ethernet cable connections and network switch status. Verify IP address configuration. Test with a known-good cable.
    Touchscreen Not Responding
    The resistive touch screen is not registering input, possibly due to driver failure or hardware fault.
    Recalibrate the touch screen via the Windows control panel. Reinstall touch screen drivers. If unresolved, inspect the touch controller hardware.

    Frequently Asked Questions

    What display size and resolution does the 6AV7611-0AE22-0BG0 provide?

    This unit features a 15-inch TFT color LCD with a resolution of 1024 x 768 pixels (XGA) and resistive touch screen input.

    What operating system does the SIMATIC Panel PC 670 run?

    The Panel PC 670 runs Microsoft Windows XP Professional or Windows XP Embedded, supporting standard PC-based HMI and SCADA software including Siemens WinCC.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces for connectivity to PLCs, networks, and peripheral devices.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7611-0AE22-0BG0 carries an IP65 protection rating, making it resistant to dust and water jets for panel-mount installations.

    Is this Panel PC compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to run Siemens WinCC and other SIMATIC HMI software packages, as it operates on a standard Windows PC platform.

    Troubleshooting

    Panel PC does not power on after switching on the supply

    Check the 24 V DC power supply voltage at the power connector. Verify that the supply is within the specified input voltage range and that all connectors are firmly seated.

    Ensure the power supply output is stable and within specification. Replace the power supply unit if voltage is absent or out of range. Check internal fuses if accessible.

    Display is blank but the PC appears to be running (fans active, LEDs on)

    The backlight inverter or the TFT panel itself may have failed. Connect an external monitor via the VGA port to determine if the PC is outputting video.

    If the external monitor shows output, the internal display or backlight inverter requires replacement. If no output is present, investigate graphics driver or hardware failure.

    Touch screen input is inaccurate or unresponsive

    The resistive touch screen may require recalibration, or the touch controller driver may have become corrupted.

    Access the touch screen calibration utility in the Windows Control Panel and perform a full recalibration. If the issue persists, reinstall the touch screen driver or replace the touch screen assembly.

    System freezes or reboots unexpectedly during operation

    Check the Windows Event Viewer for critical errors preceding the freeze or reboot. Monitor CPU temperature and verify adequate ventilation around the unit.

    Clean any dust from ventilation openings. Ensure ambient temperature is within the 0 to 45 °C operating range. If hardware faults are logged, test RAM and storage devices and replace as necessary.

    Ethernet communication lost to PLC or SCADA server

    Verify physical Ethernet connection and check the link LED on the RJ45 port. Confirm IP address settings in Windows Network Connections.

    Replace the Ethernet cable if damaged. Reconfigure the IP address if it has changed. Update or reinstall the network adapter driver if the interface is not recognized by the operating system.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-0AA15-2AX0 TP 270

      Siemens 6AV6545-0AA15-2AX0 TP 270

      € 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart