• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AE20-0CG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AE20-0CG0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AE20-0CG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AE20-0CG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-performance computing platform with a robust industrial enclosure, providing a reliable operator interface for complex process control applications.

    The SIMATIC Panel PC 670 (6AV7611-0AE20-0CG0) features a 12-inch TFT display with a resolution of 800 x 600 pixels and a touch-sensitive screen for intuitive operator interaction. The unit is equipped with an Intel Celeron processor and runs Microsoft Windows, supporting SIMATIC WinCC and other SCADA/HMI software packages. It provides standard industrial communication interfaces including Ethernet and serial ports, and is designed to operate within an extended industrial temperature range. The front panel achieves IP65 protection, making it resistant to dust and water ingress from the front.

    The SIMATIC Panel PC 670 is widely deployed in manufacturing, automotive, chemical processing, and energy industries where a full PC-based HMI platform is required. It is particularly suited for applications demanding high graphical performance, data logging, and integration with enterprise-level systems via standard PC interfaces. Its panel-mount design allows direct integration into control cabinets and operator stations on the factory floor.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Front Protection Rating IP65
    Rear Protection Rating IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), RS-232, RS-422/485
    Mounting Panel mount
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL, cUL

    Common Error Codes and System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly, possibly due to a corrupted system partition or failed storage device.
    Check the hard disk or CompactFlash card for errors. Attempt a system restore or reinstall the operating system. Verify the boot sequence in BIOS.
    Event ID: 1000
    Application fault — the HMI or SCADA software (e.g. WinCC) has crashed unexpectedly.
    Restart the application. Check the Windows Event Viewer for detailed error logs. Reinstall or repair the HMI software if the fault persists.
    Event ID: 6008
    Unexpected shutdown — the system was shut down uncleanly, often due to a power interruption or hardware fault.
    Check the 24 V DC power supply for stability and correct voltage. Inspect all power connectors. Review Windows Event Viewer for prior error entries.
    Communication Error
    Loss of communication between the Panel PC and the connected PLC or automation controller.
    Verify Ethernet or serial cable connections. Check IP address configuration and network settings. Confirm the PLC is powered and running.
    Watchdog Timeout
    The system watchdog has triggered due to the CPU or application becoming unresponsive.
    Restart the Panel PC. Check for excessive CPU or memory load. Ensure the HMI application is correctly configured and not entering an infinite loop.
    Temperature Warning
    Internal temperature of the Panel PC has exceeded the normal operating threshold.
    Check that ventilation slots are not blocked. Verify ambient temperature is within the 0–50 °C operating range. Clean any dust from cooling vents and fans.
    Hard Disk Failure
    The internal hard disk or storage medium has reported errors or is not detected by the system.
    Replace the hard disk or CompactFlash card. Restore the system image from a backup. Ensure the replacement storage device is compatible with the Panel PC model.

    Frequently Asked Questions

    What operating system does the SIMATIC Panel PC 670 (6AV7611-0AE20-0CG0) support?

    The 6AV7611-0AE20-0CG0 is designed to run Microsoft Windows (typically Windows XP Professional or Windows 2000 depending on the configuration ordered). It supports SIMATIC WinCC and other standard Windows-based HMI and SCADA software.

    What is the supply voltage for this Panel PC?

    The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.

    What is the front panel protection rating of the 6AV7611-0AE20-0CG0?

    The front panel of this unit is rated IP65, providing full protection against dust ingress and protection against low-pressure water jets. The rear of the unit is rated IP20.

    Is the 6AV7611-0AE20-0CG0 compatible with Siemens WinCC?

    Yes, the SIMATIC Panel PC 670 is fully compatible with Siemens SIMATIC WinCC visualization software, as well as other Windows-based HMI and SCADA applications.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45) for network connectivity, as well as RS-232 and RS-422/RS-485 serial interfaces for connection to PLCs and other automation devices.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector. Verify that the supply is within tolerance and that all connectors are firmly seated. Check if the power LED on the unit is illuminated.

    If the supply voltage is correct but the display remains blank, the internal power supply board or the display backlight inverter may have failed. Inspect internal fuses and replace the faulty module. If the unit does not respond at all, the mainboard may require replacement.

    Touchscreen does not respond or responds inaccurately

    Attempt to recalibrate the touchscreen using the Windows control panel or the SIMATIC calibration utility. Check for physical damage or contamination on the screen surface.

    Recalibrate the touchscreen through the operating system settings. Clean the screen surface with a soft, dry cloth. If calibration fails repeatedly, the touchscreen overlay may need to be replaced.

    Panel PC fails to boot into Windows

    Listen for hard disk activity during startup. Enter the BIOS setup to verify that the boot device is detected. Check the CompactFlash card or hard disk for physical seating and connection.

    Reseat the storage device. If the drive is detected but Windows fails to load, attempt a repair installation of the operating system. If the drive is not detected, replace the hard disk or CompactFlash card and restore from a system backup image.

    Loss of communication with connected PLC

    Check the Ethernet or serial cable connections between the Panel PC and the PLC. Verify the IP address and subnet mask settings in Windows. Confirm the PLC is powered and in RUN mode.

    Replace or reseat the communication cable. Reconfigure the network settings if the IP address has been lost. Restart both the Panel PC and the PLC. If using a serial connection, verify the COM port settings (baud rate, parity, stop bits) match the PLC configuration.

    System runs slowly or HMI application freezes

    Open Windows Task Manager to check CPU and memory utilization. Identify any processes consuming excessive resources. Check available disk space on the system drive.

    Close unnecessary background applications. Free up disk space by removing temporary files. If the hard disk is nearly full, archive data logs and alarm records. Consider increasing virtual memory settings or, if the hardware supports it, upgrading the RAM.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart