• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AE12-0BF0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AE12-0BF0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AE12-0BF0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AE12-0BF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a high-performance computing platform with an integrated flat-panel display in a rugged, industrial-grade enclosure.

    The SIMATIC Panel PC 670 6AV7611-0AE12-0BF0 features a 12-inch TFT display with a touch-sensitive screen for operator interaction, and is built around an x86-compatible processor platform running a Windows-based operating system. It supports standard industrial communication interfaces including Ethernet and serial ports, and is compatible with Siemens SIMATIC WinCC and ProTool/Pro visualization software. The unit is designed for front-panel mounting with an IP65-rated front bezel, providing protection against dust and water ingress in industrial environments.

    This Panel PC is widely used in manufacturing, process automation, and machine tool industries where a full PC-based HMI solution is required. Its ability to run standard Windows software alongside SCADA and HMI applications makes it suitable for complex visualization tasks, data logging, and process monitoring. The robust construction and industrial-grade components make it appropriate for continuous operation in factory floor environments.

    Technical Specifications

    Display Size 12.1 inch
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Communication Interface Ethernet (RJ45), RS-232, USB
    Mounting Panel mounting
    Operating System Windows XP Embedded / Windows 2000
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes and System Events

    Event ID: 100
    System startup failure — the Panel PC fails to complete the boot sequence, often due to a corrupted operating system or failed storage medium.
    Check the CompactFlash card or hard disk for errors. Reinstall or restore the operating system image using the Siemens recovery tool.
    Event ID: 1000
    Application crash — the HMI or SCADA application (e.g. WinCC) has terminated unexpectedly.
    Review the Windows Event Viewer logs for the faulting module. Reinstall or repair the HMI software installation and check for software compatibility issues.
    Event ID: 7000
    Service failed to start — a required Windows service did not start during boot, which may prevent the HMI application from launching.
    Check the Windows Event Viewer System log for the specific service name. Verify service startup settings and dependencies, and repair or reinstall the affected software component.
    Communication Error
    Loss of communication between the Panel PC and the connected PLC or automation controller via Ethernet or serial interface.
    Verify network cable connections and IP address configuration. Check the communication driver settings in WinCC or ProTool/Pro and confirm the PLC is online and reachable.
    Watchdog Timeout
    The system watchdog has detected that the application or operating system has become unresponsive and has triggered a reset.
    Investigate the cause of the application hang. Check CPU and memory utilization, update or reinstall the HMI application, and ensure adequate system resources are available.
    Temperature Warning
    Internal temperature sensor has detected that the Panel PC is operating above the recommended thermal threshold.
    Check that ventilation slots are unobstructed and that ambient temperature is within the specified operating range of 0 °C to +50 °C. Clean any dust from internal fans or heat sinks if accessible.
    Power Supply Fault
    The 24 V DC supply voltage is outside the acceptable operating range, causing the Panel PC to shut down or fail to start.
    Measure the supply voltage at the power input connector. Ensure the supply is stable and within the specified 24 V DC range. Check wiring and the external power supply unit.

    Frequently Asked Questions

    What operating system does the 6AV7611-0AE12-0BF0 run?

    The SIMATIC Panel PC 670 6AV7611-0AE12-0BF0 is typically supplied with Windows XP Embedded or Windows 2000, depending on the configuration ordered. It supports standard x86-compatible Windows software.

    What HMI software is compatible with this Panel PC?

    This unit is compatible with Siemens SIMATIC WinCC and ProTool/Pro RT visualization software. It can also run other standard Windows-based SCADA and HMI applications.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7611-0AE12-0BF0 is rated IP65, providing protection against dust ingress and low-pressure water jets. The rear of the unit is rated IP20.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), RS-232 serial, and USB interfaces for connectivity to PLCs, networks, and peripheral devices.

    Can this Panel PC be used as a replacement for an older SIMATIC Panel PC 670 unit?

    Yes, the 6AV7611-0AE12-0BF0 is a direct replacement within the SIMATIC Panel PC 670 family, provided the software image and configuration are transferred correctly. Verify hardware revision compatibility before installation.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the supply voltage at the power input connector to confirm it is within the 24 V DC operating range. Inspect the internal fuse if accessible.

    Ensure the external power supply is providing stable 24 V DC. Replace any blown internal fuse with the correct rating. If the unit still does not power on, the internal power supply board may require replacement.

    Display is blank but the system appears to be running (LEDs active, HDD activity)

    Check the display cable connection between the mainboard and the TFT panel. Test with an external monitor if a VGA output is available to determine if the fault is in the display or the graphics output.

    Reseat the internal display cable connections. If the TFT panel or backlight inverter is faulty, replace the display assembly. If the graphics output is faulty, the mainboard may need to be replaced.

    Touchscreen does not respond or responds inaccurately

    Check if the touch controller driver is correctly installed in the Windows Device Manager. Attempt to recalibrate the touchscreen using the Siemens or manufacturer calibration utility.

    Recalibrate the touchscreen via the control panel calibration tool. If the issue persists, reinstall the touch controller driver. If hardware damage is suspected, the touchscreen overlay may need to be replaced.

    HMI application fails to connect to the PLC

    Verify the Ethernet or serial cable connections between the Panel PC and the PLC. Check the IP address configuration and communication driver settings within WinCC or ProTool/Pro.

    Correct any IP address conflicts or misconfigured communication parameters. Replace faulty cables. Ensure the PLC is in RUN mode and that the correct communication driver is installed and configured on the Panel PC.

    System runs slowly or HMI application freezes intermittently

    Check CPU and RAM utilization in Windows Task Manager. Inspect the CompactFlash card or hard disk for errors using a disk check utility. Check for excessive background processes consuming resources.

    Remove unnecessary startup programs and background services. Run a disk integrity check and replace the storage medium if errors are found. If RAM is insufficient, consider upgrading if the hardware supports it.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart