Siemens 6AV7611-0AE12-0BE0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE12-0BE0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling it to run SCADA, HMI, and process visualization software directly on the panel.
The SIMATIC Panel PC 670 (6AV7611-0AE12-0BE0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touch-sensitive screen for operator interaction. It is built around an industrial-grade PC platform supporting Windows-based operating systems and is equipped with communication interfaces including Ethernet and serial ports for integration with PLCs and automation networks. The unit is designed for panel mounting with an IP65-rated front face, providing protection against dust and water ingress in industrial environments. It supports standard PC expansion options and is compatible with Siemens SIMATIC WinCC and other SCADA/HMI software packages.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a robust, integrated PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and water treatment, where reliable visualization and control are critical. Its panel-mount design and industrial-grade construction make it appropriate for installation directly in control cabinets and operator stations on the production floor.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| IP/Protection Rating | IP65 (front face) |
| Mounting | Panel mounting |
| Operating Temperature | 0 °C to 45 °C |
| Storage Temperature | -20 °C to 60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | Ethernet (RJ45), RS-232, RS-422/485 |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
| Operating System | Windows XP Embedded / Windows 2000 |
Common Error Codes & System Events
- Event ID: 1001
- Operating system startup failure or boot error detected during POST sequence
Check hard disk or CompactFlash card integrity. Verify OS installation and boot configuration. Replace storage media if corrupted. - Event ID: 1003
- Application error or system process crash recorded in Windows event log
Review Windows Event Viewer for details. Reinstall the affected application or update drivers. Check for memory faults using diagnostic tools. - Event ID: 2001
- Communication interface error — loss of connection to PLC or automation network
Check Ethernet or serial cable connections. Verify IP address configuration and network settings. Confirm PLC communication parameters match HMI project settings. - Event ID: 3001
- Touchscreen calibration error or touch input not responding correctly
Recalibrate the touchscreen using the Siemens calibration utility in the control panel. Clean the screen surface. If persistent, inspect touchscreen controller hardware. - Event ID: 4001
- Fan failure or thermal warning — internal temperature exceeding operating threshold
Check and clean cooling fan and ventilation slots. Ensure ambient temperature is within the 0–45 °C operating range. Replace fan unit if faulty. - Event ID: 5001
- Power supply voltage out of range — 24 V DC supply deviation detected
Measure the 24 V DC supply at the power connector. Ensure supply is within tolerance. Check wiring and power supply unit output. - Event ID: 6001
- Hard disk or CompactFlash storage device not detected or read error
Reseat the storage device. Check for physical damage. Replace the hard disk or CompactFlash card and restore the OS image from backup. - Event ID: 7001
- BIOS or firmware configuration error — CMOS checksum failure
Replace the CMOS battery on the motherboard. Re-enter BIOS settings and save configuration. Update BIOS firmware if required.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AE12-0BE0?
The SIMATIC Panel PC 670 (6AV7611-0AE12-0BE0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
What display size and resolution does this Panel PC have?
This unit features a 12-inch TFT color LCD display with a resolution of 800 x 600 pixels (SVGA) and a resistive touchscreen for operator input.
What communication interfaces are available on this unit?
The 6AV7611-0AE12-0BE0 is equipped with Ethernet (RJ45), RS-232, and RS-422/485 serial interfaces for connecting to PLCs, automation networks, and peripheral devices.
Is this Panel PC compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens SIMATIC WinCC and other Windows-based SCADA and HMI visualization software packages.
What is the front panel protection rating of this unit?
The front face of the 6AV7611-0AE12-0BE0 carries an IP65 protection rating, making it resistant to dust and water jets for use in industrial environments.
Troubleshooting
Panel PC does not power on after 24 V DC is applied
Measure the 24 V DC supply voltage at the power input connector. Check internal fuse and wiring continuity. Verify the power supply unit output is within tolerance.
Replace any blown internal fuse with the correct rating. If the power supply unit is faulty, replace it. Ensure the 24 V DC source is stable and within the specified voltage range.
Display is blank or shows no image after power on
Check if the unit is booting by listening for disk activity or observing status LEDs. Measure backlight supply voltage. Connect an external monitor via VGA port if available to isolate display vs. system fault.
Replace the backlight inverter or TFT display panel if the backlight has failed. If the system is not booting, check the storage device and OS integrity. Reseat RAM modules and expansion cards.
Touchscreen does not respond or registers incorrect touch positions
Attempt to operate the unit using a USB mouse to confirm the OS is running. Check touchscreen controller connections internally. Verify touchscreen calibration settings in the OS control panel.
Recalibrate the touchscreen using the Siemens calibration utility. If calibration fails, inspect the touchscreen ribbon cable connection. Replace the touchscreen overlay if the controller or surface is damaged.
Loss of communication with PLC or network devices
Check Ethernet and serial cable connections at both the Panel PC and PLC ends. Verify IP address, subnet mask, and gateway settings in the OS network configuration. Confirm communication driver settings in the HMI project.
Correct any network configuration mismatches. Replace damaged cables or connectors. Update or reinstall the communication driver. If using RS-232/RS-485, verify baud rate, parity, and stop bit settings match the connected device.
System freezes or restarts unexpectedly during operation
Check Windows Event Viewer for critical errors or application crashes. Monitor CPU and memory usage. Inspect cooling fan operation and measure internal temperature. Check for storage device errors using disk diagnostics.
Clean the cooling fan and ventilation slots to restore airflow. Replace the fan if it has failed. Run disk diagnostics and replace the storage device if errors are found. Increase available RAM or optimize running applications to reduce resource load.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6545-0AA15-2AX0 TP 270
€ 399,00 – € 1.149,00Price range: € 399,00 through € 1.149,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page