Siemens 6AV7611-0AE12-0AG0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE12-0AG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial automation environments. This unit integrates a flat-panel display with a fully functional PC platform, enabling both operator control and data processing within a single device.
The SIMATIC Panel PC 670 (6AV7611-0AE12-0AG0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is equipped with an Intel Celeron processor and runs on a Windows-based operating system, providing compatibility with standard SCADA and HMI software including SIMATIC WinCC. The unit offers multiple communication interfaces including Ethernet (RJ45) and standard PC ports (USB, serial), and is built to withstand industrial environments with a front panel protection rating of IP65.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine tool industries where a robust, integrated PC-based HMI solution is required. Its fanless or low-maintenance design makes it suitable for continuous operation in production lines, packaging machinery, and process control cabinets. The combination of standard PC architecture and industrial-grade construction allows integration with a broad range of automation systems and third-party software applications.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Type | TFT LCD |
| Display Resolution | 800 x 600 pixels (SVGA) |
| Touch Technology | Resistive touch screen |
| Input Voltage | 24 V DC |
| Communication Interface | Ethernet (RJ45), USB, RS-232 |
| Operating System | Windows XP / Windows 2000 (factory configurable) |
| Processor | Intel Celeron |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup failure or BIOS POST error detected during boot sequence
Check hardware connections, reseat RAM and storage media, verify BIOS settings, and restore factory BIOS defaults if necessary - Event ID: 1000
- Application fault or software exception causing unexpected program termination
Review Windows Event Viewer logs, reinstall the affected HMI or SCADA application, and ensure software compatibility with the installed OS version - Event ID: 26
- Device driver error, typically related to display or communication adapter
Reinstall or update the relevant device driver; verify hardware compatibility and check Device Manager for conflict flags - Communication Error
- Loss of communication between Panel PC and connected PLC or automation controller
Check Ethernet cable integrity and connections, verify IP address configuration, and confirm PLC communication settings match Panel PC project configuration - Watchdog Timeout
- System watchdog timer has triggered due to software hang or unresponsive application
Restart the Panel PC, investigate the application causing the hang, and check for memory or CPU overload conditions - Storage Media Error
- Read/write error on CompactFlash card or hard disk drive
Back up data immediately, run a disk check utility, and replace the storage medium if errors persist; use only Siemens-approved storage media - Temperature Warning
- Internal temperature has exceeded the recommended operating threshold
Check ambient temperature, ensure adequate ventilation around the panel cutout, clean any dust from ventilation slots, and verify cooling fan operation if applicable
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AE12-0AG0?
The SIMATIC Panel PC 670 (6AV7611-0AE12-0AG0) operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel devices.
What is the front panel protection rating of this Panel PC?
The front panel of the 6AV7611-0AE12-0AG0 carries an IP65 protection rating, making it resistant to dust and water jets, suitable for panel-mounted industrial installations.
Is this Panel PC compatible with SIMATIC WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with SIMATIC WinCC and other Siemens HMI software packages, as it runs a Windows-based operating system on standard PC architecture.
What communication interfaces are available on this unit?
The 6AV7611-0AE12-0AG0 provides Ethernet (RJ45), USB ports, and RS-232 serial interfaces, enabling connectivity to PLCs, networks, and peripheral devices.
Can the storage medium on this Panel PC be replaced or upgraded?
Yes, the SIMATIC Panel PC 670 uses a CompactFlash card or hard disk drive as its storage medium, which can be replaced; Siemens-approved storage media should be used to ensure compatibility and reliability.
Troubleshooting
Display remains blank after power is applied
Measure 24 V DC at the power supply connector. Check the internal fuse and verify the backlight inverter is functioning by looking for a faint image on the screen.
Replace the internal fuse if blown, or replace the backlight inverter or display assembly if the backlight has failed. Confirm the 24 V DC supply is stable and within tolerance.
Touch screen does not respond or registers incorrect touch positions
Check whether the touch controller is recognized in Windows Device Manager. Verify that the touch screen calibration has not been corrupted.
Recalibrate the touch screen using the Windows control panel or Siemens calibration utility. If the issue persists, inspect the touch screen connector and replace the touch screen overlay if damaged.
Panel PC fails to boot or continuously restarts
Observe the boot sequence for BIOS POST errors. Check the CompactFlash card or hard disk for read errors using a disk utility booted from external media.
Replace the storage medium with a Siemens-approved CompactFlash card and restore the system image from a backup. Reseat RAM modules and verify all internal connectors are secure.
Loss of communication with PLC or network devices
Verify the Ethernet cable and switch port are functioning. Check the IP address configuration in Windows Network Settings and confirm the PLC project settings match.
Replace the Ethernet cable if faulty, correct IP address or subnet mask mismatches, and ensure the correct communication driver is installed and configured in the HMI application.
System runs slowly or HMI application freezes
Check CPU and memory utilization in Windows Task Manager. Identify any background processes consuming excessive resources or storage media fragmentation.
Close unnecessary background applications, defragment the hard disk or replace a worn CompactFlash card, and ensure the installed HMI software version is compatible with the Panel PC hardware configuration.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA11-0AX0 OP 73micro
€ 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page