Siemens 6AV7611-0AE10-0CH0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AE10-0CH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC platform, enabling both operator control and data processing within a single integrated device.
The SIMATIC Panel PC 670 features a 15-inch TFT display with a resolution of 1024 x 768 pixels (XGA) and supports touch screen operation for intuitive operator interaction. It is built around an industrial-grade processor platform running Microsoft Windows, with onboard RAM and storage options suited for SCADA and HMI software such as Siemens WinCC. The unit provides standard PC interfaces including USB, serial (RS-232), and Ethernet ports, and is designed for front-panel mounting with an IP65-rated front bezel for protection against dust and water ingress.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a robust, integrated PC-based HMI solution is required. It is suitable for industries such as automotive, food and beverage, chemical processing, and water treatment, where reliable visualization and control at the machine level are critical. Its panel-mount design and industrial-grade construction make it appropriate for installation in control cabinets and operator panels in harsh industrial environments.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Resolution | 1024 x 768 px (XGA) |
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Communication Interface | Ethernet (RJ45), RS-232, USB |
| Operating System | Microsoft Windows XP / Windows 2000 |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 100
- System startup error — the operating system failed to boot correctly or a critical system file is missing.
Check hard disk or CompactFlash card integrity. Reinstall or restore the operating system image using the Siemens recovery partition or backup medium. - Event ID: 1000
- Application crash — a running HMI or SCADA application (e.g. WinCC) has terminated unexpectedly.
Check Windows Event Viewer for the faulting module. Update or reinstall the affected application. Verify software version compatibility with the Panel PC firmware. - Event ID: 7034
- Service terminated unexpectedly — a critical Windows service required for HMI operation stopped without a controlled shutdown.
Restart the service via Windows Service Manager. If recurring, check for corrupted system files using the Windows System File Checker (sfc /scannow). - Event ID: 6008
- Unexpected shutdown — the system was shut down uncleanly, typically due to a power loss or hardware fault.
Verify the 24 V DC supply voltage stability. Check power supply connections and ensure adequate current capacity. Inspect for loose wiring at the power connector. - BIOS POST Error
- Hardware initialization failure during Power-On Self-Test — RAM, CPU, or peripheral hardware not detected correctly.
Reseat RAM modules and expansion cards. Clear CMOS settings and restore BIOS defaults. If fault persists, replace the defective hardware component. - Watchdog Timeout
- The hardware watchdog timer has triggered a system reset because the operating system or application became unresponsive.
Investigate CPU load and memory usage. Optimize or reduce background processes. Check for software loops in the HMI application. Update drivers and firmware if available. - Touch Controller Error
- The touchscreen controller is not responding or touch input is not being registered correctly.
Recalibrate the touchscreen via the Siemens calibration utility in the control panel. Check the internal ribbon cable connection between the display and the motherboard. Replace the touch controller if calibration fails.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AE10-0CH0?
The SIMATIC Panel PC 670 operates on a 24 V DC supply voltage. Ensure the power source provides sufficient current capacity for stable operation.
What operating system does the 6AV7611-0AE10-0CH0 support?
This Panel PC was designed to run Microsoft Windows XP Professional or Windows 2000, which are the supported operating systems for the SIMATIC Panel PC 670 series with this hardware configuration.
Is the 6AV7611-0AE10-0CH0 compatible with Siemens WinCC?
Yes, the SIMATIC Panel PC 670 is compatible with Siemens WinCC visualization software. The specific WinCC version must be matched to the installed operating system and available hardware resources.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AE10-0CH0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets. The rear of the unit is rated IP20.
Can the storage medium be replaced or upgraded on this Panel PC?
The SIMATIC Panel PC 670 supports replaceable storage media such as CompactFlash cards or hard disk drives depending on the configuration. Siemens provides recovery tools to restore the operating system image after a storage medium replacement.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator is illuminated. Listen for fan activity to determine if the unit is powering on internally.
If supply voltage is correct but display is blank, reseat the internal display cable connections. Test with an external monitor if a VGA output is available. If the backlight has failed, replace the CCFL backlight or the display assembly.
Touchscreen does not respond to input or registers incorrect touch positions
Attempt to operate the unit using a USB mouse to determine if the issue is isolated to the touch controller. Check Device Manager in Windows for touch controller errors or missing drivers.
Run the Siemens touchscreen calibration utility from the control panel. If calibration does not resolve the issue, check the internal ribbon cable connecting the touch panel to the motherboard. Replace the touch screen overlay if the controller hardware is confirmed faulty.
Unit fails to boot and displays a BIOS error or stops at POST screen
Note the specific POST error code or beep sequence displayed. Check whether the storage medium (CompactFlash or HDD) is detected in the BIOS setup menu.
Reseat the storage medium and RAM modules. Restore BIOS settings to factory defaults. If the storage medium is not detected, replace it and restore the operating system using the Siemens recovery image or a backup.
WinCC or HMI application crashes repeatedly during operation
Review the Windows Event Viewer application log for error codes and faulting module names. Monitor CPU and RAM usage during operation to identify resource exhaustion.
Ensure the installed WinCC version is compatible with the operating system and Panel PC hardware. Disable unnecessary background applications and services. Reinstall the HMI application if corrupted files are suspected.
Ethernet communication is lost or the network interface is not recognized
Check the Ethernet cable and switch port for link activity LEDs. Open Device Manager to verify the network adapter is listed without errors. Ping the unit from another device on the same network segment.
Reinstall the Ethernet adapter driver from the Siemens driver package for the Panel PC 670. Check and reset the IP address configuration. If the adapter is not detected after driver reinstallation, the onboard NIC may require hardware repair or motherboard replacement.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3607-1NH00-0AX0 OP7
€ 615,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page