Siemens 6AV7611-0AB22-0BH0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AB22-0BH0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. The unit integrates a display, computing hardware, and industrial-grade I/O into a single compact enclosure suitable for panel mounting.
The SIMATIC Panel PC 670 (6AV7611-0AB22-0BH0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touch-sensitive screen for operator interaction. It is powered by an Intel Celeron processor and runs Microsoft Windows XP or Windows 2000, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB, Ethernet (RJ45), serial COM ports, and a parallel port, enabling integration with a wide range of peripheral devices and control systems. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC Panel PC 670 is widely used in manufacturing automation, process control, and machine visualization applications across industries such as automotive, food and beverage, chemical processing, and packaging. Its ruggedized industrial design, combined with standard PC architecture, makes it suitable for use as a central visualization station on the factory floor where both computing flexibility and environmental robustness are required. The device is compatible with Siemens SIMATIC S7 PLC families via PROFIBUS or Industrial Ethernet communication.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Front Panel Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Communication Interface | Ethernet (RJ45), USB, RS-232 (COM), Parallel port |
| Operating System | Microsoft Windows XP / Windows 2000 |
| Processor | Intel Celeron |
| Operating Temperature | 0 °C to +45 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- System startup failure — the Panel PC fails to complete the boot sequence, often due to a corrupted operating system or failed storage medium.
Check the CompactFlash card or hard disk for errors. Reinstall or restore the operating system image using the Siemens recovery tool. - Event ID: 101
- Hardware watchdog timeout — the watchdog timer has triggered a system reset due to an application or OS hang.
Investigate the running HMI application for software loops or memory leaks. Update or reinstall the WinCC or HMI runtime software. - Event ID: 200
- Communication loss to PLC — the Panel PC has lost communication with the connected SIMATIC S7 controller via Ethernet or PROFIBUS.
Check network cabling, IP address configuration, and PROFIBUS DP address settings. Verify the communication driver is correctly configured in WinCC. - Event ID: 201
- PROFIBUS DP interface error — the integrated or external PROFIBUS adapter reports a bus fault or address conflict.
Verify PROFIBUS cable termination, check for duplicate station addresses, and confirm the DP master configuration in STEP 7. - Event ID: 300
- Touchscreen calibration error — the touch input is misaligned or unresponsive after a system restart.
Run the touchscreen calibration utility from the Windows Control Panel or the Siemens calibration tool. If the issue persists, inspect the touchscreen controller hardware. - Event ID: 400
- Fan failure or overtemperature warning — the internal cooling fan has stopped or the CPU temperature has exceeded the operating threshold.
Clean or replace the internal cooling fan. Ensure the ambient temperature is within the 0 °C to +45 °C operating range and that ventilation slots are unobstructed. - Event ID: 500
- Storage medium error — the CompactFlash card or hard disk drive reports read/write errors or is not detected at startup.
Replace the CompactFlash card or HDD with a compatible unit. Restore the system image using the Siemens backup/restore utility. - Event ID: 600
- Power supply undervoltage — the 24 V DC supply voltage has dropped below the minimum operating threshold.
Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance and check wiring connections.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7611-0AB22-0BH0?
The unit operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance to prevent system faults.
What operating system does the SIMATIC Panel PC 670 (6AV7611-0AB22-0BH0) run?
This Panel PC supports Microsoft Windows XP Professional and Windows 2000, and is compatible with Siemens SIMATIC WinCC and other standard HMI/SCADA software packages.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AB22-0BH0 carries an IP65 protection rating, providing full dust protection and resistance to water jets from any direction.
Which communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, RS-232 serial (COM) ports, and a parallel port, enabling connectivity to PLCs, peripherals, and network infrastructure.
Is this Panel PC compatible with Siemens SIMATIC S7 controllers?
Yes, the SIMATIC Panel PC 670 can communicate with SIMATIC S7-300 and S7-400 PLCs via Industrial Ethernet or PROFIBUS DP using the appropriate communication drivers configured in WinCC.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the internal power LED or status indicator is active. Listen for fan operation to confirm the unit is receiving power.
If voltage is present but the display is blank, reseat the display cable internally if accessible. If the backlight has failed, replace the inverter board or the TFT display assembly. If no power is detected, inspect the power supply wiring and fusing.
Touchscreen does not respond or input is misaligned
Attempt to operate the unit using a connected USB keyboard or mouse to determine if the OS is running correctly. Check Device Manager in Windows for touchscreen controller errors.
Run the Siemens touchscreen calibration utility from the Control Panel. If calibration does not resolve the issue, update or reinstall the touchscreen driver. In persistent cases, replace the touchscreen overlay or controller board.
Panel PC fails to boot or gets stuck at the Windows startup screen
Check the CompactFlash card or hard disk drive for physical damage or loose connections. Attempt to boot from an external recovery medium to determine if the storage device is readable.
Restore the factory system image using the Siemens recovery tool and a compatible CompactFlash card or replacement HDD. Ensure the replacement storage medium is of the correct type and capacity specified for this model.
Loss of communication with SIMATIC S7 PLC
Verify the Ethernet or PROFIBUS cable connections at both the Panel PC and the PLC. Check the IP address configuration in Windows and the WinCC communication channel settings. Use the STEP 7 hardware diagnostics to check the PLC-side connection.
Correct any IP address conflicts or PROFIBUS address mismatches. Replace faulty cables or connectors. Reinstall the communication driver in WinCC if the channel reports a configuration error.
Unit shuts down unexpectedly or reboots without warning
Check the ambient temperature around the Panel PC and inspect the cooling fan for operation. Review the Windows Event Viewer for hardware or software error entries logged before the shutdown.
Clean dust from ventilation slots and replace a failed cooling fan with a compatible unit. If overtemperature is not the cause, check the 24 V DC supply for voltage drops under load. Investigate and resolve any software application causing a watchdog timeout.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-2AX0 TP177B
€ 714,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA12-0AB0 TP177B
€ 879,00Select options This product has multiple variants. The options may be chosen on the product page