• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AB20-0CG0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AB20-0CG0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AB20-0CG0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AB20-0CG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. The unit integrates a display and computing hardware into a single rugged enclosure suitable for direct panel installation.

    The SIMATIC Panel PC 670 6AV7611-0AB20-0CG0 is equipped with a 12-inch TFT display and runs on a standard x86-compatible processor platform, supporting Windows-based operating systems for compatibility with SIMATIC WinCC and other SCADA/HMI software packages. It provides multiple communication interfaces including Ethernet and standard PC ports (USB, serial), enabling integration into existing automation networks. The unit features a fanless or low-maintenance design philosophy typical of the Panel PC 670 family, with an industrial-grade power supply accepting 24 V DC input.

    The SIMATIC Panel PC 670 is widely deployed in manufacturing, process automation, and machine building applications where a full PC-based HMI platform is required. It is suitable for use in automotive assembly lines, chemical processing plants, and packaging machinery where reliable visualization, data logging, and process control are needed simultaneously. Its panel-mount form factor and industrial certifications make it appropriate for integration directly into control cabinets and operator stations.

    Technical Specifications

    Series SIMATIC Panel PC 670
    Display Size 12 inch
    Display Type TFT LCD
    Input Voltage 24 V DC
    Communication Interface Ethernet (RJ45), USB, RS-232
    Operating System Windows XP / Windows 2000 (compatible)
    Mounting Panel mounting
    Protection Rating (Front) IP65
    Protection Rating (Rear) IP20
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Certifications CE, UL
    Power Consumption Max. 80 W

    Common Error Codes and System Events

    Event ID: 100
    System startup error — the operating system failed to boot correctly or a critical system file is missing.
    Check the hard disk or CompactFlash card for errors. Reinstall or restore the operating system image if necessary.
    Event ID: 1001
    Application crash or unexpected software termination detected by Windows error reporting.
    Review the Windows event log for the faulting application. Reinstall the HMI software (e.g. WinCC) or update drivers.
    BIOS POST Error
    Hardware self-test failure during power-on, indicating a memory or hardware component fault.
    Reseat RAM modules and expansion cards. If the error persists, replace the faulty hardware component or the main board.
    WinCC Runtime Error
    SIMATIC WinCC runtime application has encountered a configuration or communication error and cannot start.
    Verify the WinCC project configuration and communication settings. Check the connection to the PLC and restart the runtime application.
    Network Communication Error
    Loss of Ethernet communication between the Panel PC and the connected PLC or SCADA system.
    Check Ethernet cable connections and switch/hub status. Verify IP address configuration and firewall settings on the Panel PC.
    Hard Disk / Storage Fault
    The internal storage device (HDD or CompactFlash) is not detected or reports read/write errors.
    Replace the internal storage medium. Restore the system image from a backup. Ensure the storage device is correctly seated in its connector.
    Watchdog Timeout
    The system watchdog has triggered a reset due to the operating system or application becoming unresponsive.
    Investigate software processes causing high CPU load. Check for memory leaks in the HMI application and ensure adequate system resources are available.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7611-0AB20-0CG0?

    The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC Panel PC 670 devices intended for industrial panel installation.

    What display size does the 6AV7611-0AB20-0CG0 have?

    This Panel PC is equipped with a 12-inch TFT display, providing sufficient screen area for complex HMI visualization and operator interaction.

    Is this Panel PC compatible with SIMATIC WinCC?

    Yes, the SIMATIC Panel PC 670 is designed to run SIMATIC WinCC and other Windows-based HMI and SCADA software packages, as it operates on a standard x86 PC platform with a Windows operating system.

    What is the front panel protection rating of the 6AV7611-0AB20-0CG0?

    The front panel of the 6AV7611-0AB20-0CG0 carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets.

    Can the operating system or storage medium be replaced on this unit?

    Yes, the internal storage medium (HDD or CompactFlash depending on the configuration) can be replaced. Siemens provides system restore images to reinstall the operating system after a storage replacement.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power input connector. Verify that the supply is within tolerance and that the power LED or indicator shows activity.

    If supply voltage is correct, inspect the internal fuse and the backlight inverter board. Replace the backlight or inverter if the display is confirmed to receive power but produces no image.

    Panel PC does not boot and shows BIOS error on screen

    A POST (Power-On Self-Test) error indicates a hardware fault. Identify the error code displayed and check RAM seating and internal connections.

    Reseat or replace RAM modules. If the error relates to the storage device, replace the HDD or CompactFlash card and restore the system image from a Siemens recovery backup.

    Touchscreen does not respond to input

    Check whether the touchscreen controller is recognized in Device Manager under the Windows operating system. Inspect the flat-flex cable connecting the touch panel to the main board.

    Recalibrate the touchscreen using the Windows control panel or Siemens calibration utility. If the cable is damaged or the controller is faulty, replace the touchscreen assembly.

    Loss of communication with PLC over Ethernet

    Verify the Ethernet cable and switch port. Check the IP address configuration on the Panel PC and confirm the PLC is reachable via ping from the Panel PC.

    Correct any IP address conflicts or misconfiguration. Replace the Ethernet cable if faulty. If the onboard NIC is defective, install a compatible USB-to-Ethernet adapter or replace the network interface hardware.

    WinCC runtime application crashes repeatedly

    Review the Windows event log and WinCC diagnostic files for error messages. Check available disk space and RAM usage during runtime operation.

    Free up disk space and ensure the system meets the minimum resource requirements for the WinCC version installed. Reinstall or repair the WinCC installation, and verify that the project configuration is free of errors.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart