• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AA20-0BJ0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AA20-0BJ0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AA20-0BJ0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AA20-0BJ0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a built-in display with a full PC architecture, enabling both operator control and data processing within a single compact device.

    The SIMATIC Panel PC 670 (6AV7611-0AA20-0BJ0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and a touch-sensitive front panel for operator interaction. It is based on an x86-compatible processor architecture and runs Microsoft Windows operating systems, supporting SIMATIC WinCC and other SCADA/HMI software packages. The unit provides standard PC interfaces including USB ports, serial COM ports, and an Ethernet interface for network connectivity and integration with Siemens S7 PLCs via PROFINET or Industrial Ethernet. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.

    The SIMATIC Panel PC 670 is widely used in manufacturing, automotive, food and beverage, and process industries where a robust, panel-mounted PC-based HMI solution is required. It is suited for applications demanding local visualization, recipe management, data logging, and process monitoring at the machine level. Its compatibility with standard PC software and Siemens automation ecosystems makes it a practical choice for integration into existing SIMATIC-based control architectures.

    Technical Specifications

    Display Size 12 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    IP Protection Rating (Front) IP65
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +45 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM ports)
    Operating System Microsoft Windows XP / Windows 2000
    Mounting Panel mounting
    Series/Product Family SIMATIC Panel PC 670
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 100
    System startup failure — the Panel PC fails to complete the boot sequence, often due to a corrupted operating system or failed storage medium.
    Check the CompactFlash card or hard disk for errors. Reinstall or restore the operating system image using the Siemens recovery tool.
    Event ID: 1000
    Application crash — the HMI or SCADA software (e.g. WinCC) has terminated unexpectedly.
    Review the Windows Event Viewer for application error details. Reinstall or repair the HMI software. Check for software compatibility with the installed OS version.
    Event ID: 7000
    Service failed to start — a required Windows service did not start during boot, preventing normal HMI operation.
    Check the Windows Event Log for the specific service name. Verify service startup settings and dependencies. Reinstall the affected software component if necessary.
    Communication Error
    Loss of communication between the Panel PC and the connected PLC (e.g. S7-300/400) via Industrial Ethernet or MPI.
    Verify Ethernet cable connections and network configuration. Check IP address settings and ensure the PLC is powered and reachable. Review WinCC channel driver configuration.
    Watchdog Timeout
    The system watchdog has detected that the operating system or application has stopped responding within the defined time window.
    Perform a controlled restart of the Panel PC. Investigate CPU load and running processes. If recurring, check for hardware faults such as failing RAM or storage media.
    Temperature Warning
    Internal temperature of the Panel PC has exceeded the recommended operating threshold.
    Check that ventilation slots are unobstructed. Verify ambient temperature is within the 0–45 °C operating range. Inspect and clean any internal cooling fans if present.
    Storage Media Error
    Read/write error detected on the CompactFlash card or hard disk drive used as the system storage medium.
    Replace the CompactFlash card or hard disk. Restore the operating system and HMI application from a backup image. Ensure the replacement media is Siemens-approved for this Panel PC model.

    Frequently Asked Questions

    What display size and resolution does the 6AV7611-0AA20-0BJ0 have?

    This Panel PC features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA). The display includes a resistive touchscreen for operator input.

    What operating system does the SIMATIC Panel PC 670 (6AV7611-0AA20-0BJ0) support?

    The unit supports Microsoft Windows XP Professional and Windows 2000, which are compatible with Siemens SIMATIC WinCC and other standard HMI software packages.

    What is the supply voltage for this Panel PC?

    The 6AV7611-0AA20-0BJ0 operates on a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in SIMATIC environments.

    Is the front panel of this unit protected against dust and water?

    Yes, the front panel of the SIMATIC Panel PC 670 meets IP65 protection rating, providing full protection against dust ingress and resistance to water jets.

    What communication interfaces are available on this Panel PC?

    The unit provides an RJ45 Ethernet port for Industrial Ethernet or PROFINET connectivity, USB ports, and RS-232 serial COM ports for peripheral and PLC communication.

    Troubleshooting

    Panel PC does not boot or display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify that the CompactFlash card or hard disk is properly seated and not corrupted. Listen for POST beep codes.

    Reseat the storage media. If the storage medium is faulty, replace the CompactFlash card and restore the OS image using the Siemens recovery procedure. Verify the power supply output is stable at 24 V DC.

    Touchscreen does not respond or registers incorrect touch positions

    Check if the touchscreen calibration has been lost, which can occur after an OS reinstallation or system crash. Inspect the touchscreen connector inside the unit for loose connections.

    Recalibrate the touchscreen using the Windows control panel touchscreen calibration utility. If calibration fails, inspect and reseat the internal touchscreen ribbon cable. Replace the touchscreen assembly if the hardware is damaged.

    Loss of communication with S7 PLC via Ethernet

    Verify the Ethernet cable is connected and the link LED on the RJ45 port is active. Check the IP address configuration of the Panel PC and the PLC. Review the WinCC communication channel driver settings.

    Correct any IP address conflicts or subnet mismatches. Replace the Ethernet cable if faulty. Reconfigure the WinCC channel driver with the correct PLC connection parameters and restart the HMI application.

    HMI application (WinCC) crashes repeatedly at runtime

    Check the Windows Event Viewer for application error logs. Verify that the installed WinCC version is compatible with the operating system and the Panel PC hardware. Check available disk space and RAM.

    Reinstall or repair the WinCC runtime software. Ensure all Siemens software patches and service packs are applied. If the storage medium is nearly full, archive old log files and increase available disk space.

    Panel PC overheats and shuts down unexpectedly

    Check the ambient temperature around the panel installation. Inspect ventilation openings for dust blockage. Verify that the Panel PC is installed with adequate clearance as specified in the mounting guidelines.

    Clean dust from ventilation slots using compressed air. Ensure the installation environment does not exceed 45 °C ambient temperature. If an internal fan is present, verify it is operating correctly and replace it if faulty.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart