Siemens 6AV7611-0AA13-0CG0 SIMATIC Panel PC 670
€ 1.770,00
The Siemens 6AV7611-0AA13-0CG0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel-mounted PC designed for demanding human-machine interface (HMI) and visualization tasks in industrial environments. This unit combines a flat-panel display with an integrated PC platform, providing a compact and robust solution for process visualization and control.
The SIMATIC Panel PC 670 (6AV7611-0AA13-0CG0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an x86-compatible processor platform and is equipped with interfaces including USB, Ethernet (RJ45), and serial ports (RS-232/RS-422/RS-485), enabling integration with a wide range of automation systems. The unit operates on 24 V DC supply voltage and is designed to meet industrial EMC and environmental standards, with a front panel protection rating of IP65.
The SIMATIC Panel PC 670 is widely used in manufacturing, process automation, and machine building applications where a robust, panel-integrated PC with visualization capabilities is required. It is suitable for use with Siemens SIMATIC WinCC and other SCADA or HMI software packages, making it applicable in industries such as automotive, food and beverage, chemical processing, and general factory automation. Its fanless or low-maintenance design options make it appropriate for environments where reliability and reduced maintenance intervals are critical.
Technical Specifications
| Display Size | 12 inch |
|---|---|
| Display Resolution | 800 x 600 pixels (SVGA) |
| Display Type | TFT color LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Voltage Range | 19.2 V DC – 28.8 V DC |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Communication Interfaces | Ethernet RJ45, USB, RS-232, RS-422/RS-485 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC Panel PC 670 |
Common Error Codes & System Events
- Event ID: 100
- Loss of communication between the Panel PC and the connected PLC or automation system.
Check Ethernet or serial cable connections, verify network configuration and IP address settings, and confirm the PLC is online and reachable. - Event ID: 1000
- Operating system startup failure or boot error detected during power-on sequence.
Check the CompactFlash card or hard disk for errors, reseat the storage media, and if necessary restore or reinstall the operating system image. - Event ID: 200
- Watchdog timeout — the application software has stopped responding within the expected time frame.
Restart the HMI application. If the fault recurs, check for software conflicts, insufficient memory, or corrupted project files and reload the project. - Event ID: 300
- Internal temperature warning — the Panel PC internal temperature has exceeded the warning threshold.
Check ambient temperature and ensure adequate ventilation around the panel cutout. Clean any air vents or filters and verify the operating environment is within specification. - Event ID: 400
- Power supply undervoltage detected — the 24 V DC supply voltage has dropped below the minimum threshold.
Measure the supply voltage at the power connector and ensure it is within the 19.2 V DC to 28.8 V DC range. Check wiring, connectors, and the power supply unit. - Event ID: 500
- Touchscreen calibration error or touch input not responding correctly.
Perform a touchscreen recalibration via the Windows Control Panel or SIMATIC configuration tool. If the problem persists, inspect the touchscreen connector and consider replacing the touch overlay. - Event ID: 600
- Storage media error — read/write error detected on the CompactFlash card or hard disk.
Back up project data immediately if possible. Run a disk check utility, and if errors persist, replace the CompactFlash card or storage device and restore the system image.
Frequently Asked Questions
What is the supply voltage for the 6AV7611-0AA13-0CG0?
The unit operates on a 24 V DC supply voltage with an allowable range of 19.2 V DC to 28.8 V DC.
What is the display size and resolution of this Panel PC?
The 6AV7611-0AA13-0CG0 features a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA).
What HMI software is compatible with the SIMATIC Panel PC 670?
The Panel PC 670 is compatible with Siemens SIMATIC WinCC, WinCC flexible, and other Windows-based SCADA and HMI software packages that support the installed operating system.
What is the front panel protection rating of this unit?
The front panel of the 6AV7611-0AA13-0CG0 carries an IP65 protection rating, making it suitable for environments where dust and water spray may be present.
What communication interfaces are available on this Panel PC?
The unit provides Ethernet (RJ45), USB ports, and serial interfaces (RS-232 and RS-422/RS-485) for connectivity to PLCs, automation networks, and peripheral devices.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the voltage is within the 19.2 V DC to 28.8 V DC range. Inspect internal fuses if accessible.
Restore the supply voltage to the correct range. If the supply is correct and the display remains blank, the internal power supply board or the display backlight inverter may be faulty and require replacement.
Touchscreen does not respond or responds inaccurately
Determine whether the issue is a calibration problem or a hardware fault by observing if touch inputs are registered at all in the operating system. Check the touchscreen controller connection internally.
Recalibrate the touchscreen using the Windows Control Panel or the SIMATIC calibration utility. If calibration does not resolve the issue, inspect the touchscreen ribbon cable connection and replace the touch overlay if damaged.
Panel PC fails to boot or continuously restarts
Attempt to boot into the BIOS/UEFI setup to determine if the storage media is detected. Check the CompactFlash card or hard disk for physical damage or loose seating.
Reseat the storage media and attempt to boot again. If the device is not detected or errors persist, replace the CompactFlash card and restore the factory system image using the Siemens recovery procedure.
Loss of communication with the connected PLC
Check the Ethernet cable and RJ45 connector for physical damage. Verify the IP address configuration on both the Panel PC and the PLC. Use the ping command to test network connectivity.
Replace any damaged cables or connectors. Correct the IP address, subnet mask, and gateway settings in the network configuration. Ensure the PLC program and HMI project use matching communication parameters.
Unit overheating or thermal shutdown
Check the ambient temperature around the panel installation. Inspect the panel cutout dimensions to ensure adequate clearance as specified in the installation manual. Verify that ventilation slots are not obstructed.
Reduce the ambient temperature or improve cabinet ventilation. Ensure the panel cutout and installation clearances comply with Siemens specifications. Clean any dust from ventilation areas and confirm the unit is not installed near heat sources.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page