• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7611-0AA13-0CF0 SIMATIC Panel PC 670
    Awaiting product image

    Siemens 6AV7611-0AA13-0CF0 SIMATIC Panel PC 670

    € 1.770,00

    Reset
    Clear
    SKU: 6AV7611-0AA13-0CF0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7611-0AA13-0CF0 is a Panel PC belonging to the SIMATIC Panel PC 670 series, manufactured by Siemens. It is an industrial panel computer designed for demanding human-machine interface (HMI) and visualization tasks in automation environments. This unit combines a flat-panel display with an integrated PC platform, offering a compact and robust solution for process visualization and control.

    The SIMATIC Panel PC 670 (6AV7611-0AA13-0CF0) features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It is built around an x86-compatible processor platform and is equipped with standard PC interfaces including USB, serial (COM), and Ethernet ports for connectivity to controllers and networks. The unit supports Windows-based operating systems and is designed for front-panel mounting with an IP65 protection rating on the front face, making it suitable for use in industrial enclosures.

    This Panel PC is widely used in manufacturing, process industries, and machine building applications where a full PC-based HMI platform is required. It is suitable for running SCADA software, Siemens WinCC, and other visualization packages. Its rugged construction and industrial-grade components make it appropriate for continuous operation in factory floor environments where reliability and longevity are critical.

    Technical Specifications

    Display Size 12 inch
    Display Type TFT LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Operating Temperature 0 °C to 45 °C
    Storage Temperature -20 °C to 60 °C
    Relative Humidity 5 % to 90 % (non-condensing)
    Communication Interface Ethernet (RJ45), USB, RS-232 (COM)
    Mounting Panel mounting (front mount)
    Series / Product Family SIMATIC Panel PC 670
    Certifications CE, UL
    Operating System Support Windows XP / Windows CE compatible

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST sequence.
    Check hard disk or CompactFlash card integrity. Verify boot device is correctly configured in BIOS. Replace storage medium if corrupted.
    Event ID: 200
    Watchdog timeout triggered — the system did not respond within the defined watchdog interval.
    Check CPU load and running processes. Ensure the watchdog application is correctly configured. Restart the Panel PC and investigate software causing the hang.
    Event ID: 300
    Fan failure or thermal warning — internal cooling fan has stopped or temperature threshold exceeded.
    Inspect and clean the cooling fan. Ensure ambient temperature is within specification (0–45 °C). Replace the fan if it is not operating.
    Event ID: 400
    Power supply undervoltage — the 24 V DC supply voltage has dropped below the permissible operating range.
    Measure the supply voltage at the power connector. Ensure the supply is stable at 24 V DC. Check wiring and power supply unit output.
    Event ID: 500
    Ethernet communication error — loss of network connection or network interface fault detected.
    Check Ethernet cable and switch/hub connection. Verify IP address configuration. Inspect the RJ45 connector for damage and replace cable if necessary.
    Event ID: 600
    Touchscreen calibration error — touch input is not responding correctly or is misaligned.
    Run the touchscreen calibration utility from the Windows control panel or SIMATIC configuration tool. Clean the touch surface and recalibrate. Replace the touch overlay if calibration fails repeatedly.
    Event ID: 700
    Storage medium error — read/write error on the internal hard disk or CompactFlash card.
    Run a disk check utility (chkdsk). Back up data immediately. Replace the CompactFlash card or hard disk if errors persist.

    Frequently Asked Questions

    What is the supply voltage for the 6AV7611-0AA13-0CF0?

    The SIMATIC Panel PC 670 (6AV7611-0AA13-0CF0) operates on a 24 V DC supply voltage. Ensure the power source is stable and within the permissible voltage tolerance.

    What is the display size and resolution of this Panel PC?

    This unit features a 12-inch TFT display with a resolution of 800 x 600 pixels (SVGA). It supports resistive touchscreen input.

    What operating systems are supported by this Panel PC?

    The SIMATIC Panel PC 670 supports Windows XP Embedded and is compatible with Siemens WinCC and other Windows-based SCADA and HMI software packages.

    What is the front panel protection rating of the 6AV7611-0AA13-0CF0?

    The front panel of this unit carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial enclosure mounting.

    What communication interfaces are available on this Panel PC?

    The unit provides Ethernet (RJ45), USB ports, and RS-232 serial (COM) interfaces, allowing connectivity to PLCs, networks, and peripheral devices.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power input connector with a multimeter. Check for blown internal fuses or wiring faults.

    Ensure the supply voltage is stable at 24 V DC within tolerance. Replace any blown fuses. If the internal power supply board is faulty, it will require replacement or professional repair.

    Display is blank or backlight does not illuminate

    Check if the unit is powered (listen for fan operation or check status LEDs). Determine whether the PC is booting but the display is not showing output, or whether the backlight has failed.

    Verify display cable connections internally. Replace the CCFL backlight or inverter board if the backlight has failed. If the display panel itself is damaged, replace the TFT assembly.

    Touchscreen input is inaccurate or unresponsive

    Attempt to use a USB mouse to confirm the operating system is running correctly. Check if the touch controller driver is loaded and functioning in Device Manager.

    Recalibrate the touchscreen using the calibration utility. Clean the touch surface with a soft cloth. If the touch overlay is physically damaged or the controller has failed, replace the touchscreen assembly.

    Unit freezes or reboots unexpectedly during operation

    Check CPU temperature and fan operation. Review Windows Event Viewer logs for application or system errors. Monitor supply voltage stability.

    Clean the cooling fan and heatsink to prevent thermal shutdown. Ensure the 24 V DC supply is stable. Investigate software processes causing high CPU load and update or reinstall the HMI application if necessary.

    Ethernet connection is not established or drops intermittently

    Check the Ethernet cable and switch port. Verify IP address settings in Windows Network Connections. Test with a known-good cable.

    Replace the Ethernet cable. Reconfigure the IP address settings if incorrect. If the onboard NIC is faulty, install a USB-to-Ethernet adapter as a workaround or arrange board-level repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA11-0AX0 OP 73micro

      Siemens 6AV6640-0CA11-0AX0 OP 73micro

      € 368,00 – € 1.055,00Price range: € 368,00 through € 1.055,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart