• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7412-2AB00-0BT0 SIMATIC IPC477C
    Awaiting product image

    Siemens 6AV7412-2AB00-0BT0 SIMATIC IPC477C

    € 2.195,00

    Reset
    Clear
    SKU: 6AV7412-2AB00-0BT0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7412-2AB00-0BT0 is a panel PC belonging to the SIMATIC IPC477C series, manufactured by Siemens as part of its industrial PC product line. This unit is a 15-inch touch-enabled industrial panel computer designed for demanding automation and process visualization environments. It combines the functionality of an HMI operator panel with the computing power of an industrial PC, running a standard Windows operating system.

    The IPC477C features a 15-inch TFT LCD display with a resistive touchscreen interface and a resolution of 1024 x 768 pixels (XGA). It is equipped with an Intel Core 2 Duo or Celeron processor depending on the configuration, and supports DDR3 RAM with options for solid-state or hard disk storage. The unit provides multiple communication interfaces including Ethernet (RJ45), USB ports, and optional PROFIBUS or PROFINET connectivity. It is built to IP65 protection rating on the front panel, making it suitable for environments where dust and water ingress are a concern. The device supports 24 V DC supply voltage and is designed for panel mounting.

    The SIMATIC IPC477C is widely used in the manufacturing, automotive, food and beverage, and chemical processing industries. It is typically deployed as an operator workstation for SCADA systems, process visualization, and machine control applications where a full PC environment is required alongside HMI functionality. Its rugged construction and industrial-grade components make it suitable for continuous operation in harsh factory floor conditions.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    IP Protection Rating (Front) IP65
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interfaces 2x Ethernet RJ45, 4x USB, 1x RS-232
    Mounting Panel mounting
    Operating System Windows XP Professional / Windows 7
    Series/Product Family SIMATIC IPC477C
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 1001
    Application error or system process crash detected by Windows Event Log
    Check Windows Event Viewer for detailed error information. Restart the affected application or service. Update or reinstall the software if the issue persists.
    Event ID: 6008
    Unexpected system shutdown or power loss recorded in Windows Event Log
    Verify the 24 V DC power supply stability. Check for loose power connectors. Investigate potential hardware faults causing unexpected shutdowns.
    BIOS POST Error
    Hardware component not detected or failed during Power-On Self-Test
    Check that all internal memory modules and storage devices are properly seated. Clear CMOS settings and retry. Replace faulty hardware components as identified.
    Watchdog Timeout
    System watchdog timer has triggered due to software or OS hang
    Identify and terminate the hanging process. Check for OS or application updates. If recurring, review watchdog configuration settings in the BIOS or application.
    Fan Failure Warning
    CPU or system cooling fan has stopped or is running below minimum speed threshold
    Inspect and clean the cooling fan. Replace the fan if it is defective. Ensure adequate ventilation around the panel PC enclosure.
    Hard Disk Error
    Storage device read/write error or disk health warning detected
    Run a disk diagnostic utility (e.g., SMART check). Back up data immediately. Replace the hard disk or SSD if errors are confirmed.
    Temperature Warning
    Internal system temperature has exceeded the defined threshold
    Check ambient temperature around the unit. Clean air vents and filters. Verify that the cooling fan is operational and that the installation environment meets specifications.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7412-2AB00-0BT0?

    The unit operates on a 24 V DC supply voltage, which is standard for SIMATIC panel PCs used in industrial environments.

    What is the front panel protection rating of the IPC477C?

    The front panel of the IPC477C carries an IP65 protection rating, providing protection against dust ingress and water jets.

    What communication interfaces are available on this panel PC?

    The 6AV7412-2AB00-0BT0 provides two Ethernet RJ45 ports, multiple USB ports, and an RS-232 serial interface. Optional PROFIBUS or PROFINET interfaces may also be available depending on the configuration.

    What operating system does the SIMATIC IPC477C support?

    The IPC477C supports Windows XP Professional and Windows 7, depending on the hardware configuration and order variant.

    Is the 6AV7412-2AB00-0BT0 compatible with Siemens WinCC and STEP 7 software?

    Yes, the SIMATIC IPC477C is compatible with Siemens WinCC SCADA and visualization software, as well as STEP 7 and TIA Portal engineering environments, making it suitable for use as an operator station in Siemens automation systems.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is illuminated. Measure voltage at the internal power supply output.

    Ensure the 24 V DC supply is within tolerance. If the power supply is functioning but the display remains blank, the display backlight inverter or the TFT panel itself may need replacement.

    Touchscreen does not respond or responds inaccurately

    Check if the touchscreen is recognized in Windows Device Manager. Attempt to recalibrate the touchscreen using the Windows calibration utility.

    Recalibrate the resistive touchscreen via the operating system's touch calibration tool. If the issue persists, clean the screen surface and check the touchscreen controller connection. Replace the touchscreen assembly if calibration fails repeatedly.

    System fails to boot and shows BIOS error or stops at POST screen

    Disconnect external peripherals and attempt to boot. Check that RAM modules and storage devices are properly seated. Listen for BIOS beep codes indicating specific hardware faults.

    Reseat memory modules and storage devices. Reset BIOS settings to default. If the system still fails to boot, identify the faulty component (RAM, HDD/SSD, or mainboard) and replace accordingly.

    Unit overheats and shuts down unexpectedly

    Monitor internal temperature via BIOS or system monitoring software. Inspect cooling fan operation and check for blocked ventilation openings.

    Clean dust from ventilation slots and the cooling fan. Ensure the installation environment temperature is within the 0 to 50 °C operating range. Replace the cooling fan if it is not operating correctly.

    Ethernet communication is not established

    Check the Ethernet cable connection and verify link LEDs on the RJ45 port. Confirm network settings (IP address, subnet mask) in Windows Network Settings.

    Replace the Ethernet cable if damaged. Reconfigure the network adapter settings in Windows. Update the network adapter driver if the interface is not recognized. If both ports are non-functional, the network interface card or mainboard may require replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart