• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7285-6RC00-0AA0 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7285-6RC00-0AA0 SIMATIC IPC277D

    € 1.094,00

    Reset
    Clear
    SKU: 6AV7285-6RC00-0AA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7285-6RC00-0AA0 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial-grade embedded Panel PC family. It is designed for use as a human-machine interface (HMI) and industrial computing platform, combining a touchscreen display with a fanless embedded PC architecture. This unit is built to meet the demanding requirements of industrial environments, offering a robust all-in-one solution for visualization and control tasks.

    The IPC277D features a 15-inch widescreen TFT display with a resistive touchscreen and a resolution of 1024 x 768 pixels. It is powered by an Intel Atom processor and runs on Microsoft Windows Embedded Standard 7 or Windows Embedded Compact 7, depending on the configuration. The unit supports communication via PROFINET, Ethernet (RJ45), USB ports, and optionally PROFIBUS, enabling integration into a wide range of automation networks. It operates on a 24 V DC supply and is rated IP65 on the front panel, making it suitable for installation in control cabinet doors and operator panels.

    The SIMATIC IPC277D is widely used in manufacturing, process automation, automotive production, and machine tool industries where a robust, space-saving HMI solution is required. Its fanless design reduces maintenance requirements and improves reliability in dusty or harsh environments. The device is compatible with Siemens WinCC flexible, WinCC Runtime Advanced, and TIA Portal-based visualization software, making it a natural fit for Siemens-based automation architectures.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Processor Intel Atom
    Input/Operating Voltage 24 V DC
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Communication Interface 2x PROFINET/Ethernet RJ45, 4x USB 2.0
    Operating System Windows Embedded Standard 7 or Windows Embedded Compact 7
    Mounting Panel mounting (flush mount)
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup failure or boot error detected during POST.
    Check storage medium integrity, verify boot device in BIOS settings, and restore or reinstall the operating system image if corrupted.
    Event ID: 200
    Touchscreen calibration error or touch input not responding correctly.
    Recalibrate the touchscreen via the Windows control panel or Siemens calibration utility. If the issue persists, check the touch controller connection internally.
    Event ID: 300
    PROFINET communication loss or network interface fault.
    Check Ethernet cable connections, verify IP address configuration, and confirm PROFINET device name assignment in the TIA Portal or Step 7 project.
    Event ID: 400
    24 V DC supply undervoltage detected.
    Measure the supply voltage at the power connector. Ensure the power supply unit provides a stable 24 V DC within the specified tolerance range.
    Event ID: 500
    Internal temperature exceeded operating limit.
    Check ambient temperature around the panel PC. Ensure ventilation slots are not blocked. Verify that the installation environment does not exceed 50 °C.
    Event ID: 600
    USB device fault or unrecognized USB peripheral connected.
    Disconnect the USB device and reconnect. Ensure the USB device is compatible and drivers are installed. Avoid using non-industrial USB hubs.
    Event ID: 700
    WinCC Runtime application crash or visualization software failure.
    Restart the WinCC Runtime application. Check the application event log for specific error details. Reinstall the runtime software if the issue recurs.
    Event ID: 800
    Storage medium (Compact Flash or SSD) read/write error.
    Check the storage medium for errors using Windows disk check utilities. Replace the storage medium if hardware faults are detected and restore the system image.

    Frequently Asked Questions

    What is the supply voltage for the Siemens 6AV7285-6RC00-0AA0?

    The SIMATIC IPC277D operates on a 24 V DC supply voltage. Ensure the power source is stable and within the specified tolerance to avoid operational issues.

    What operating systems are supported by this panel PC?

    The IPC277D supports Windows Embedded Standard 7 (WES7) and Windows Embedded Compact 7 (WEC7), depending on the specific configuration ordered. The 6AV7285-6RC00-0AA0 variant should be verified against the Siemens product configurator for the exact OS version.

    Is this panel PC compatible with Siemens TIA Portal and WinCC?

    Yes, the SIMATIC IPC277D is compatible with Siemens WinCC Runtime Advanced and TIA Portal-based visualization projects. It is also compatible with the legacy WinCC flexible runtime environment.

    What is the front panel protection rating of this unit?

    The front panel of the IPC277D is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for flush mounting in control cabinet doors.

    What communication interfaces are available on this panel PC?

    The unit provides two PROFINET/Industrial Ethernet RJ45 ports and four USB 2.0 ports as standard. Optional PROFIBUS DP connectivity may be available depending on the configuration.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the power connector using a multimeter. Verify that the power LED indicator is active. Inspect internal fuses if accessible.

    Ensure the 24 V DC supply is stable and within tolerance. If the supply is correct and the display remains blank, the internal power supply board or backlight inverter may require replacement.

    Touchscreen does not respond or registers incorrect touch positions

    Attempt to recalibrate the touchscreen through the Windows control panel. Check if the touch input is completely absent or simply offset, which indicates a calibration issue versus a hardware fault.

    Recalibrate the touchscreen using the Siemens calibration utility or Windows touch calibration tool. If recalibration fails, inspect the touch controller ribbon cable connection internally or replace the touchscreen assembly.

    PROFINET communication is lost or the device cannot be found on the network

    Verify the Ethernet cable connection and check the link LEDs on the RJ45 port. Confirm the IP address and PROFINET device name are correctly configured in the TIA Portal project.

    Re-assign the PROFINET device name using TIA Portal or the Siemens Primary Setup Tool. Replace the Ethernet cable if the link LED is not active. Check network switch configuration for VLAN or port issues.

    WinCC Runtime application fails to start or crashes on boot

    Review the Windows Event Viewer application log for error codes related to WinCC Runtime. Check available storage space on the system drive and verify the integrity of the WinCC installation.

    Free up disk space if the storage medium is near capacity. Repair or reinstall the WinCC Runtime software. If the storage medium shows errors, replace it and restore the system image from a backup.

    Panel PC runs slowly or becomes unresponsive during operation

    Monitor CPU and memory usage via Windows Task Manager. Check for background processes consuming excessive resources. Verify that the operating temperature is within the specified range.

    Disable unnecessary startup programs and background services. Ensure the ambient temperature does not exceed 50 °C. If performance issues persist, consider restoring the system to a clean factory image.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart