• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7285-6KN10-0AA0 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7285-6KN10-0AA0 SIMATIC IPC277D

    € 743,00

    Reset
    Clear
    SKU: 6AV7285-6KN10-0AA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7285-6KN10-0AA0 is a panel PC belonging to the SIMATIC IPC277D series, manufactured by Siemens as part of its industrial computing portfolio. This unit is a 15-inch multi-touch panel PC designed for demanding industrial environments, combining HMI functionality with PC-based computing power in a single compact device. It is built to operate reliably in harsh industrial conditions and integrates seamlessly into Siemens automation architectures.

    The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 5 simultaneous touch points for intuitive operator interaction. It is equipped with an Intel Atom processor, onboard RAM, and solid-state storage options, providing sufficient computing performance for SCADA, visualization, and process control applications. The unit offers multiple communication interfaces including Ethernet (RJ45), USB ports, and optional PROFINET connectivity, and supports Windows Embedded Standard 7 or Windows 7 operating systems. Its fanless design and robust aluminum front panel contribute to long-term reliability and low maintenance requirements.

    The SIMATIC IPC277D is widely deployed in manufacturing, process automation, and machine building applications where a combined HMI and PC platform is required. It is suitable for use in automotive production lines, food and beverage processing, pharmaceutical manufacturing, and energy management systems. The panel PC format allows direct integration into control cabinet doors or operator panels, making it a practical choice for space-constrained installations requiring both visualization and local computing capability.

    Technical Specifications

    Display Size 15 inch
    Display Type TFT widescreen
    Touch Technology Projected capacitive (PCT) multi-touch, up to 5 touch points
    Display Resolution 1024 x 768 px
    Processor Intel Atom E3827, 1.75 GHz dual-core
    Operating Voltage 24 V DC
    Power Consumption Approx. 40 W
    Communication Interface 2x RJ45 Ethernet (10/100/1000 Mbit/s), 4x USB 2.0, 1x USB 3.0
    Operating System Windows Embedded Standard 7 / Windows 7
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting (portrait or landscape)
    Certifications CE, UL, cULus
    Design Fanless, aluminum front panel

    Common Error Codes & System Events

    Event ID: 100
    Operating system startup error or boot failure detected during POST sequence.
    Check storage medium integrity, verify OS installation, and inspect RAM modules. Re-seat or replace storage device if necessary.
    Event ID: 200
    Overtemperature condition detected on the processor or internal components.
    Check ambient temperature and ensure ventilation clearances are maintained. Clean any dust from ventilation areas and verify the installation environment is within specified limits.
    Event ID: 300
    Power supply voltage out of tolerance. Input voltage at 24 V DC supply is outside acceptable range.
    Measure the 24 V DC supply at the device connector. Ensure supply voltage is within 18 V DC to 30 V DC. Replace or adjust the power supply unit as needed.
    Event ID: 400
    Touchscreen calibration error or touch input not responding correctly.
    Recalibrate the touchscreen via the operating system control panel. If the issue persists, check the touch controller driver and reinstall if necessary.
    Event ID: 500
    Communication interface fault. Ethernet connection cannot be established.
    Check Ethernet cable connections and switch/hub configuration. Verify IP address settings and network configuration within the operating system.
    Event ID: 600
    Storage device read/write error or storage medium failure detected.
    Run a disk check utility to identify bad sectors. Back up data immediately and replace the storage medium (CFast card or SSD) if errors persist.
    Event ID: 700
    USB device not recognized or USB port fault.
    Disconnect and reconnect the USB device. Try an alternative USB port. Check device manager for driver conflicts and update or reinstall USB drivers as required.

    Frequently Asked Questions

    What is the input voltage for the Siemens 6AV7285-6KN10-0AA0?

    The device operates on a 24 V DC supply voltage, with an acceptable input range of approximately 18 V DC to 30 V DC.

    What operating system does the IPC277D support?

    The SIMATIC IPC277D supports Windows Embedded Standard 7 and Windows 7 operating systems, pre-installed depending on the ordered variant.

    Is the 6AV7285-6KN10-0AA0 compatible with Siemens WinCC and STEP 7?

    Yes, the IPC277D is fully compatible with Siemens WinCC SCADA software and can be integrated into TIA Portal-based automation projects.

    What is the IP protection rating of this panel PC?

    The front panel of the IPC277D carries an IP65 rating, making it resistant to dust ingress and water jets, suitable for industrial panel mounting.

    Can the storage medium on the IPC277D be replaced in the field?

    Yes, the IPC277D supports replaceable storage media such as CFast cards or SSDs, which can be exchanged without opening the main housing, simplifying maintenance and OS recovery.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the device input connector using a multimeter. Verify that the supply is within the 18–30 V DC range. Inspect the power LED status indicator on the device.

    Correct the supply voltage if out of range. If voltage is correct and display remains blank, perform a hard reset by holding the power button. If the issue persists, the internal power supply board or backlight inverter may require replacement.

    Touch input is unresponsive or inaccurate

    Determine whether the issue is hardware or software related by checking if the cursor moves correctly in the OS. Check for physical damage or contamination on the touch surface.

    Clean the touch surface with a soft, dry cloth. Recalibrate the touchscreen through the Windows control panel. If recalibration fails, update or reinstall the touch controller driver. In case of persistent hardware failure, the touch panel assembly may need replacement.

    Device fails to boot and displays a POST error

    Observe any error messages displayed during POST. Check whether the storage medium (CFast card or SSD) is properly seated and recognized in the BIOS.

    Re-seat the storage medium and restart the device. If the OS is corrupted, restore from a system backup or reinstall the operating system using the Siemens recovery image for the IPC277D.

    Ethernet communication cannot be established

    Check physical cable connections at both the device and the network switch. Verify link LEDs on the RJ45 port are active. Check IP configuration in the Windows network settings.

    Replace the Ethernet cable if no link LED is present. Reconfigure the IP address settings to match the network. Update the network adapter driver if the adapter is not recognized in Device Manager.

    Device overheats and shuts down unexpectedly

    Check the ambient temperature of the installation environment and compare against the specified operating range of 0–50 °C. Inspect the rear and sides of the device for obstructions blocking heat dissipation.

    Ensure minimum clearance distances around the device are maintained as specified in the installation manual. Reduce ambient temperature by improving cabinet ventilation or adding cooling. Clean any dust accumulation from the device surfaces.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart