Siemens 6AV7285-6HA10-0AA0 SIMATIC IPC277D
€ 695,00
The Siemens 6AV7285-6HA10-0AA0 is a panel PC belonging to the SIMATIC IPC277D series, manufactured by Siemens as part of its industrial PC product line. This unit is a 15-inch multi-touch panel PC designed for demanding industrial environments, combining HMI functionality with PC-based computing power in a single compact device. It is built to operate reliably in harsh industrial conditions and integrates seamlessly into Siemens automation architectures.
The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 5 simultaneous touch points for intuitive operator interaction. The unit is equipped with an Intel Atom processor, DDR3 RAM, and supports Compact Flash or SSD storage options for robust data retention. Communication interfaces include multiple USB ports, Ethernet (RJ45), and optional PROFIBUS or PROFINET connectivity, enabling integration into a wide range of industrial network topologies. The front panel carries an IP65 protection rating, making it resistant to dust and water ingress, and the unit is certified to CE and UL standards.
The SIMATIC IPC277D is widely deployed in manufacturing, process automation, and machine tool applications where a combined HMI and PC platform is required. It is particularly suited for use in the automotive, food and beverage, and chemical industries, where robust operator terminals with advanced visualization capabilities are essential. The device supports Siemens WinCC and other SCADA software packages, making it a versatile platform for complex process visualization and control tasks.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Type | TFT widescreen |
| Touch Technology | Projected capacitive (PCT) multi-touch, up to 5 touch points |
| Display Resolution | 1024 x 768 px |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | 2x USB 2.0, 2x Ethernet RJ45 (10/100/1000 Mbit/s) |
| Processor | Intel Atom |
| Mounting | Panel mounting |
| Certifications | CE, UL |
| Series/Product Family | SIMATIC IPC277D |
Common Error Codes & System Events
- Event ID: 100001
- Runtime software startup failure — the HMI runtime application failed to initialize correctly on boot.
Check Windows Event Viewer for detailed error logs. Reinstall or repair the WinCC Runtime software. Verify storage media integrity. - Event ID: 110000
- Communication loss to PLC — the panel PC has lost its configured connection to the PLC.
Check Ethernet cable connections and network switch status. Verify PLC IP address and project configuration in WinCC. Ping the PLC from the panel to confirm network reachability. - Event ID: 140001
- Tag acquisition error — one or more process tags cannot be read from the connected controller.
Verify PLC program is running and the relevant data blocks or addresses are accessible. Check communication driver configuration in WinCC. - Event ID: 120001
- Archive error — the data or alarm archive has encountered a write failure.
Check available storage space on the configured archive drive. Verify archive path settings in WinCC project. Replace storage media if errors persist. - Event ID: 170001
- License missing or invalid — a required WinCC Runtime license is not found or has expired.
Check the license status using the Siemens Automation License Manager. Transfer or activate the correct license for the installed WinCC Runtime version. - Event ID: 130001
- Screen loading error — a configured HMI screen could not be loaded by the runtime.
Recompile and retransfer the HMI project from the engineering station. Check for corrupted project files or incompatible object types on the affected screen. - Event ID: 150001
- User administration error — user login or access control configuration is invalid or corrupted.
Reset user administration settings in the WinCC project and retransfer. Ensure the user management database file is not corrupted.
Frequently Asked Questions
What operating system does the SIMATIC IPC277D 6AV7285-6HA10-0AA0 run?
The SIMATIC IPC277D is typically supplied with Windows Embedded Standard 7 (WES7) or Windows 7 Ultimate, depending on the order configuration. The specific variant 6AV7285-6HA10-0AA0 should be verified against the Siemens order documentation for the exact OS version.
What HMI software is compatible with this panel PC?
The IPC277D is compatible with Siemens WinCC Runtime Advanced and WinCC Runtime Professional, as well as other PC-based SCADA and visualization software packages that support Windows operating systems.
What is the front panel protection rating of this unit?
The front panel of the SIMATIC IPC277D carries an IP65 protection rating, providing full dust protection and protection against low-pressure water jets.
Can this panel PC communicate with Siemens S7 PLCs?
Yes, the IPC277D supports PROFINET communication via its onboard Ethernet ports and can communicate with S7-300, S7-400, S7-1200, and S7-1500 PLCs using standard Siemens communication drivers in WinCC.
What storage options are available for the IPC277D?
The IPC277D supports Compact Flash cards and solid-state drives (SSD) for the operating system and application data, providing vibration-resistant storage suitable for industrial environments.
Troubleshooting
Display remains blank after power on
Check that 24 V DC supply voltage is present at the power connector. Measure voltage at the input terminals and verify the power supply unit output. Check if the power LED on the device is illuminated.
Restore correct 24 V DC supply if absent. If supply is present but display remains blank, the internal backlight or display assembly may have failed and requires replacement. Check internal fuses if accessible.
Touch input not responding or inaccurate
Determine whether the issue is with the touch controller or the display itself by connecting an external USB mouse to verify cursor movement. Check for physical damage or contamination on the touch surface.
Clean the touch surface with a soft, dry cloth. If using gloves, ensure they are compatible with projected capacitive touch technology. Recalibrate the touch screen via the Windows control panel. If the issue persists, the PCT touch overlay may require replacement.
Panel PC fails to boot into Windows and displays a boot error
Attempt to boot from an external USB drive to determine if the issue is with the internal storage media. Check the BIOS/UEFI settings to confirm the correct boot device is selected.
If the internal storage is faulty, replace the Compact Flash card or SSD with a new unit and reinstall the operating system and WinCC Runtime using the Siemens recovery image. Restore the HMI project from backup.
Loss of communication with PLC during operation
Check the Ethernet cable connection between the panel PC and the network switch or PLC. Use the Windows network diagnostics or ping command to test connectivity. Review WinCC Runtime diagnostics for communication error messages.
Replace the Ethernet cable if damaged. Verify network switch port status and PROFINET configuration. Ensure the PLC IP address in the WinCC project matches the actual PLC network settings. Restart the WinCC Runtime if communication does not recover automatically.
WinCC Runtime crashes or restarts unexpectedly
Review the Windows Event Viewer application and system logs for error entries at the time of the crash. Check available RAM and CPU usage during operation. Verify that the installed WinCC Runtime version is compatible with the project version.
Ensure the panel PC meets the minimum hardware requirements for the WinCC Runtime version in use. Update or reinstall WinCC Runtime if corrupted. Reduce project complexity or optimize screen update cycles if resource exhaustion is identified.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page