Siemens 6AV7260-2CA10-0AX1 SIMATIC IPC277D
€ 2.217,00
The Siemens 6AV7260-2CA10-0AX1 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding automation and process visualization environments. This unit is a 15-inch widescreen multi-touch panel PC that integrates computing power and HMI functionality into a single compact device. It is designed for direct panel mounting and operates within the broader SIMATIC HMI ecosystem.
The IPC277D features a 15.6-inch widescreen TFT display with a resistive or projected capacitive touch interface, supporting a resolution of 1366 x 768 pixels. It is powered by an Intel Atom processor and supports Windows Embedded Standard 7 or Windows 7 operating systems, providing a familiar environment for SCADA and visualization software such as WinCC. The unit includes multiple communication interfaces including PROFINET, USB, and Ethernet ports, and is built to IEC 61131 standards for industrial environments with an IP65 front protection rating.
The SIMATIC IPC277D is widely used in manufacturing, process automation, and machine building applications where a robust, panel-mounted computing solution is required. It is particularly suited for use in automotive production lines, food and beverage processing, chemical plants, and water treatment facilities. Its compatibility with Siemens TIA Portal and WinCC software makes it a natural fit for installations already using Siemens SIMATIC S7 PLCs and distributed I/O systems.
Technical Specifications
| Display Size | 15.6 inch widescreen |
|---|---|
| Display Resolution | 1366 x 768 pixels |
| Display Type | TFT LCD |
| Touch Technology | Resistive touch |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Max. 60 W |
| Processor | Intel Atom E3827, 1.75 GHz |
| Operating System | Windows Embedded Standard 7 (WES7) |
| Communication Interface | 2x PROFINET/Ethernet RJ45, 4x USB 2.0 |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC IPC277D |
Common Error Codes & System Events
- Event ID: 100
- System startup failure or boot error detected during POST sequence
Check power supply voltage at 24 V DC input. Verify that all internal connections are secure. Attempt a hard reset and monitor boot sequence output. - Event ID: 1000
- Application error in WinCC or visualization software causing unexpected process termination
Review Windows Event Viewer logs for faulting module details. Reinstall or repair the WinCC Runtime installation. Check for software version compatibility. - Event ID: 2000
- PROFINET communication loss or network interface fault
Verify Ethernet cable integrity and connection at both ends. Check PROFINET device configuration in TIA Portal. Confirm IP address settings and subnet configuration. - Event ID: 3000
- Touchscreen input not responding or calibration error
Recalibrate the touch interface via the Windows control panel touch settings. Clean the screen surface. If unresponsive, check internal touch controller ribbon cable connection. - Event ID: 4000
- Storage device error or Compact Flash/SSD read-write failure
Run a disk check utility (chkdsk) on the storage medium. Back up data and replace the Compact Flash card or SSD if errors persist. - Event ID: 5000
- Operating temperature exceeded, thermal warning triggered
Check ambient temperature around the panel. Ensure ventilation clearances are maintained. Inspect cooling fan operation if fitted. Reduce processor load if possible. - Event ID: 6000
- USB device not recognized or USB port fault
Disconnect and reconnect the USB device. Test with a known-good USB device. Check USB port for physical damage. Update USB drivers if operating system is functional.
Frequently Asked Questions
What operating system does the SIMATIC IPC277D 6AV7260-2CA10-0AX1 run?
This unit runs Windows Embedded Standard 7 (WES7), which supports Siemens WinCC Runtime and other standard Windows-based SCADA and visualization applications.
What is the supply voltage for this panel PC?
The IPC277D requires a 24 V DC supply voltage, which is standard for industrial panel-mounted devices in automation environments.
Is this panel PC compatible with Siemens TIA Portal and WinCC?
Yes, the SIMATIC IPC277D is fully compatible with Siemens TIA Portal engineering software and WinCC Runtime, making it suitable for integration into existing Siemens SIMATIC automation systems.
What is the front panel protection rating of the IPC277D?
The front panel carries an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial environments.
What communication interfaces are available on this unit?
The unit provides two PROFINET/Industrial Ethernet RJ45 ports and four USB 2.0 ports, enabling connectivity to PLCs, network infrastructure, and peripheral devices.
Troubleshooting
Panel PC does not power on after supply is connected
Measure the 24 V DC supply voltage at the power input connector. Verify polarity is correct and that the supply can deliver sufficient current. Check for any blown internal fuses.
Correct any wiring errors or polarity issues. Replace the power supply if output voltage is out of tolerance. If internal fuse is blown, inspect for short circuits before replacing the fuse.
Display is blank but the system appears to be running (LEDs active)
Check display brightness settings in Windows. Verify that the display cable connection between the mainboard and the display panel is secure. Test with an external monitor if a video output port is available.
Adjust brightness settings via the Windows display control panel. Reseat the internal display ribbon cable. If the backlight has failed, the display panel or inverter board may require replacement.
Touchscreen is unresponsive or registers incorrect touch positions
Check whether the touch driver is correctly installed in Windows Device Manager. Attempt touch recalibration via the Windows Tablet PC Settings. Inspect the screen surface for contamination or damage.
Recalibrate the touch interface through the Windows control panel. Clean the screen with a lint-free cloth. If the issue persists after recalibration, the touch controller or digitizer layer may need replacement.
PROFINET communication to PLC is intermittent or fails entirely
Check the Ethernet cable and RJ45 connector for damage. Verify IP address configuration and subnet mask settings in Windows Network Connections. Confirm the PROFINET device name matches the configuration in TIA Portal.
Replace the Ethernet cable if damaged. Correct IP address and PROFINET device name settings. Ensure the network switch or hub is functioning correctly and that no IP address conflicts exist on the network.
System runs slowly or WinCC Runtime performance is degraded
Check CPU and memory utilization in Windows Task Manager. Identify any background processes consuming excessive resources. Check available storage space on the system drive.
Terminate unnecessary background applications and disable non-essential startup programs. Free up storage space by removing temporary files. If the storage medium is near end of life, replace the Compact Flash card or SSD with a new unit.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27
€ 749,00 – € 964,00Price range: € 749,00 through € 964,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page