• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7260-1GM30-0BX0 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7260-1GM30-0BX0 SIMATIC IPC277D

    € 1.870,00

    Reset
    Clear
    SKU: 6AV7260-1GM30-0BX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7260-1GM30-0BX0 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial-grade embedded panel PC family. It is designed for demanding human-machine interface (HMI) applications requiring a robust, fanless computing platform integrated with a touchscreen display. This unit combines the functionality of an industrial PC with a multi-touch panel in a single compact device suitable for direct panel mounting.

    The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCAP) multi-touch interface, offering a resolution of 1366 x 768 pixels. It is powered by an Intel Atom E3827 dual-core processor and runs on a 24 V DC supply. The unit supports communication via Ethernet (RJ45), USB ports, and is compatible with PROFINET. It operates without a fan or rotating storage media, enhancing reliability in industrial environments. The device supports Windows Embedded Standard 7 or Windows 7 Ultimate operating systems and is rated IP65 on the front panel.

    The SIMATIC IPC277D is widely deployed in manufacturing automation, process control, and machine tool applications where a reliable, integrated HMI solution is required. Its fanless, sealed front design makes it suitable for environments with dust, moisture, or vibration. Industries such as automotive, food and beverage, pharmaceuticals, and general factory automation commonly use this panel PC for SCADA visualization, machine control interfaces, and process monitoring tasks.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1366 x 768 pixels
    Display Type TFT widescreen
    Touch Technology Projected Capacitive (PCAP) Multi-Touch
    Processor Intel Atom E3827 dual-core
    Input Voltage 24 V DC
    Front Panel Protection Rating IP65
    Rear Protection Rating IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Mounting Panel mounting
    Communication Interface 2x Ethernet RJ45 (PROFINET compatible), 4x USB
    Operating System Windows Embedded Standard 7 / Windows 7 Ultimate
    Certifications CE, UL, cULus
    Series SIMATIC IPC277D

    Common Error Codes & System Events

    Event ID: 1001
    Application error or operating system crash event logged in Windows Event Viewer, typically indicating a software or driver fault.
    Review Windows Event Viewer logs for the faulting application or driver. Update or reinstall the relevant software or driver. If persistent, restore the OS image using the recovery partition.
    Event ID: 6008
    Unexpected system shutdown recorded by the Windows operating system, indicating the previous shutdown was unclean.
    Check the 24 V DC power supply for voltage stability and correct wiring. Inspect for power interruptions. Review event logs for preceding errors that may have caused the shutdown.
    BIOS POST Error
    The panel PC fails to complete the Power-On Self-Test during startup, indicating a hardware initialization failure.
    Disconnect all external peripherals and retry. Check that the storage medium (CFast card or SSD) is properly seated. If the error persists, the mainboard or storage device may require replacement.
    No Boot Device Found
    The operating system cannot be located on the configured boot device during startup.
    Verify that the CFast card or SSD is correctly inserted and recognized in BIOS. Check boot order settings in BIOS. Restore the OS image from the Siemens recovery medium if the storage device is intact.
    Touchscreen Not Responding
    The PCAP touch interface does not register input, which may be caused by a driver fault, hardware failure, or incorrect calibration.
    Restart the device to reload touch drivers. Check Device Manager for driver errors and reinstall the touch controller driver if necessary. If hardware failure is suspected, inspect the touch controller connection on the mainboard.
    Ethernet Link Failure
    One or both Ethernet interfaces fail to establish a network connection, preventing PROFINET or LAN communication.
    Check physical cable connections and switch port status. Verify IP configuration in Windows Network Settings. Test with a known-good cable. If the port remains inactive, inspect the NIC driver in Device Manager or replace the mainboard.
    Display Backlight Failure
    The screen remains dark after power-on despite the system appearing to boot normally, indicating a backlight or inverter fault.
    Connect an external monitor via available video output to confirm the system is running. If the external display works, the backlight or display assembly requires replacement. Check display cable connections internally.
    Watchdog Timeout Reset
    The hardware watchdog timer has triggered a system reset because the operating system or application became unresponsive.
    Investigate the application or OS process causing the hang. Review event logs for preceding errors. Ensure adequate system resources (CPU, RAM) are available. Update firmware and application software to the latest versions.

    Frequently Asked Questions

    What operating systems are supported by the 6AV7260-1GM30-0BX0?

    The SIMATIC IPC277D 6AV7260-1GM30-0BX0 supports Windows Embedded Standard 7 and Windows 7 Ultimate. It is not designed to run standard desktop Linux distributions without custom configuration.

    What is the supply voltage for this panel PC?

    The device operates on a 24 V DC power supply. Ensure the supply is stable and within the specified tolerance range to prevent unexpected shutdowns.

    Is this panel PC compatible with Siemens WinCC and SIMATIC software?

    Yes, the SIMATIC IPC277D is fully compatible with Siemens WinCC, WinCC flexible, and other SIMATIC HMI software packages, making it a standard platform for Siemens-based automation projects.

    What is the front panel protection rating of the 6AV7260-1GM30-0BX0?

    The front panel of this unit is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for industrial environments.

    Does the IPC277D support PROFINET communication?

    Yes, the unit is equipped with two RJ45 Ethernet ports that support PROFINET, enabling direct integration into Siemens PROFINET-based automation networks.

    Troubleshooting

    Panel PC does not power on after 24 V DC is applied

    Measure the 24 V DC supply voltage at the power connector to confirm it is within specification. Check the internal fuse on the power input circuit.

    Replace any blown input fuse with the correct rated fuse. Verify the power supply unit output is stable under load. If the mainboard does not initialize after confirmed correct supply voltage, the power supply board or mainboard may require replacement.

    Display is blank but the system appears to be running (fans or LEDs active)

    Connect an external monitor if a video output is available to determine whether the system is booting normally. Check the display cable connection between the mainboard and the display assembly.

    If the external monitor shows output, replace the display backlight or the full display assembly. If no video output is detected at all, suspect a mainboard or graphics subsystem fault requiring board-level repair or replacement.

    Touchscreen registers incorrect touch positions or is unresponsive

    Check Device Manager in Windows for touch controller driver errors. Verify that no physical damage or contamination is present on the touch surface.

    Reinstall the PCAP touch controller driver from the Siemens recovery image or driver package. Clean the touch surface with a dry lint-free cloth. If the hardware touch controller is faulty, the display assembly will require replacement.

    System frequently reboots or crashes unexpectedly

    Review Windows Event Viewer for critical errors, watchdog timeout events, or application crashes. Measure the 24 V DC supply for voltage drops or ripple under load.

    Stabilize the power supply and ensure correct grounding. Update all drivers and firmware to the latest Siemens-approved versions. If a specific application is causing crashes, reinstall or update it. Restore the OS image if system files are corrupted.

    Ethernet port does not establish a connection to the PROFINET network

    Check the physical cable and switch port. Open Device Manager and Network Connections in Windows to verify the NIC is recognized and the driver is loaded correctly.

    Replace the Ethernet cable and test on a known-good switch port. Reinstall the NIC driver from the Siemens recovery image. If both ports are non-functional after driver reinstallation, the mainboard network controller may be faulty and require board replacement.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart