• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7260-1GM30-0BA0 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7260-1GM30-0BA0 SIMATIC IPC277D

    € 1.995,00

    Reset
    Clear
    SKU: 6AV7260-1GM30-0BA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7260-1GM30-0BA0 is a Panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding human-machine interface applications. This unit is a 15-inch multi-touch Panel PC that integrates computing power and display functionality into a single compact device suitable for direct panel mounting. It is manufactured by Siemens as part of the SIMATIC IPC family, which is engineered for continuous industrial operation.

    The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 5 simultaneous touch points for intuitive operator interaction. The unit is powered by an Intel Atom processor and runs Microsoft Windows Embedded Standard 7 or Windows 7, providing a familiar computing environment for SCADA and HMI software deployment. It includes multiple communication interfaces such as Ethernet (RJ45), USB ports, and optionally PROFIBUS or PROFINET, enabling seamless integration into Siemens automation networks. The device is built to IP65 protection on the front panel, making it resistant to dust and water ingress in industrial environments.

    The SIMATIC IPC277D is widely used in manufacturing automation, process control, and machine tool applications where a robust, panel-mounted operator interface is required. It is particularly suited for industries such as automotive, food and beverage, pharmaceuticals, and chemical processing, where reliable HMI operation under harsh environmental conditions is essential. Its compatibility with Siemens WinCC and other SCADA platforms makes it a natural fit for integration into existing Siemens TIA Portal-based automation architectures.

    Technical Specifications

    Display Size 15 inch
    Display Type TFT widescreen
    Touch Technology Projected capacitive (PCT) multi-touch, up to 5 touch points
    Processor Intel Atom
    Operating System Windows Embedded Standard 7 / Windows 7
    Input/Operating Voltage 24 V DC
    IP/Protection Rating IP65 (front panel)
    Communication Interface 2x Ethernet RJ45, 4x USB, optional PROFIBUS/PROFINET
    Mounting Panel mounting
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC IPC277D

    Common Error Codes & System Events

    Event ID: 100
    System startup error – the operating system failed to boot correctly, possibly due to corrupted system files or storage media failure.
    Check the CompactFlash card or SSD for errors. Attempt system restore or reinstall the operating system image using the Siemens recovery medium.
    Event ID: 101
    Hardware initialization failure – a hardware component such as RAM or the processor was not detected correctly during POST.
    Reseat internal memory modules if accessible. If the fault persists, return the unit for hardware-level diagnostics and repair.
    Event ID: 200
    Watchdog timeout – the system watchdog has triggered due to a software hang or unresponsive application.
    Restart the Panel PC. Review running applications for memory leaks or infinite loops. Update or reinstall the HMI runtime software.
    Event ID: 201
    Fan failure or thermal warning – the internal cooling fan has stopped or the CPU temperature has exceeded the warning threshold.
    Check and clean the ventilation slots. Verify the fan is operational. Ensure ambient temperature is within the specified operating range of 0 °C to +50 °C.
    Communication Error
    Loss of communication with the PLC or PROFINET/PROFIBUS network – the HMI runtime reports connection timeout or network unreachable.
    Check Ethernet or PROFIBUS cabling and connectors. Verify IP address configuration and network switch status. Restart the HMI runtime application.
    Touch Screen Not Responding
    The projected capacitive touch interface fails to register input or responds erratically.
    Clean the touch surface with a soft cloth. Recalibrate the touch screen via the Windows control panel. If the issue persists, check the touch controller ribbon cable connection internally.
    Storage Media Error
    The system reports read/write errors on the internal CompactFlash card or SSD storage device.
    Back up all data immediately. Replace the CompactFlash card or SSD with a Siemens-approved replacement and restore the system image.

    Frequently Asked Questions

    What is the display size and touch technology used in the 6AV7260-1GM30-0BA0?

    The 6AV7260-1GM30-0BA0 features a 15-inch TFT widescreen display with projected capacitive (PCT) multi-touch technology, supporting up to 5 simultaneous touch points.

    What operating system does the SIMATIC IPC277D run?

    The IPC277D supports Microsoft Windows Embedded Standard 7 or Windows 7, providing compatibility with standard industrial HMI and SCADA software packages including Siemens WinCC.

    What is the supply voltage for this Panel PC?

    The unit operates on a 24 V DC supply voltage, which is standard for Siemens industrial panel PCs and compatible with typical control cabinet power supplies.

    Is the 6AV7260-1GM30-0BA0 compatible with Siemens TIA Portal and WinCC?

    Yes, the SIMATIC IPC277D is fully compatible with Siemens TIA Portal and WinCC Runtime, making it straightforward to integrate into existing Siemens automation projects.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7260-1GM30-0BA0 is rated IP65, providing complete protection against dust ingress and resistance to water jets, suitable for industrial panel mounting environments.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power input connector. Check the internal fuse and verify the power LED status on the unit.

    Restore the correct 24 V DC supply. Replace the internal fuse if blown. If the backlight is faulty, the display panel or inverter board may require replacement.

    Panel PC does not boot into Windows – shows BIOS screen or boot error

    Check the internal storage media (CompactFlash or SSD) is properly seated and recognized in the BIOS. Attempt to boot from the Siemens recovery medium.

    Reseat or replace the CompactFlash card or SSD. Restore the factory operating system image using the Siemens-provided recovery tool or recovery USB medium.

    Touch input is unresponsive or inaccurate

    Inspect the touch surface for contamination or damage. Check the touch controller driver status in Windows Device Manager. Verify no external USB devices are interfering.

    Clean the display surface thoroughly. Reinstall the touch controller driver. Recalibrate the touch screen via the Windows control panel settings. Replace the touch overlay if physically damaged.

    Loss of communication with PLC over Ethernet or PROFINET

    Verify the Ethernet cable connection and check the link LED on the RJ45 port. Confirm the IP address settings in Windows network configuration match the project configuration in TIA Portal.

    Replace the Ethernet cable if faulty. Correct the IP address, subnet mask, and gateway settings. Restart the WinCC Runtime application and re-establish the PLC connection.

    Unit overheating or spontaneous shutdown due to high temperature

    Check the ambient temperature around the panel cutout. Inspect ventilation slots for dust blockage. Verify the internal cooling fan is spinning.

    Clean all ventilation slots with compressed air. Ensure the installation environment does not exceed 50 °C ambient temperature. Replace the internal fan if it has failed.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart