• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7260-0HD40-0CX0 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7260-0HD40-0CX0 SIMATIC IPC277D

    € 2.217,00

    Reset
    Clear
    SKU: 6AV7260-0HD40-0CX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7260-0HD40-0CX0 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial-grade embedded Panel PC lineup. It is designed for use as a human-machine interface (HMI) and industrial computing platform, combining a touch-enabled display with an embedded PC architecture. This unit is built to meet the demanding requirements of industrial environments, offering a robust and fanless design suitable for continuous operation.

    The IPC277D features a 15-inch widescreen display with a resistive or projected capacitive touch interface, depending on the variant, and runs on an Intel Atom processor platform. It supports communication via standard industrial interfaces including PROFINET, Ethernet, USB, and serial ports, enabling integration with Siemens SIMATIC S7 controllers and third-party systems. The unit is designed for panel mounting and operates on a 24 V DC supply, with an IP65-rated front face for protection against dust and water ingress.

    The SIMATIC IPC277D is widely deployed in machine building, automotive manufacturing, food and beverage processing, and general factory automation. It is commonly used as an operator panel for SCADA systems, process visualization, and machine control applications where a compact, embedded PC solution is preferred over a standalone HMI terminal. Its compatibility with Siemens WinCC and other SCADA software makes it a versatile platform for industrial visualization tasks.

    Technical Specifications

    Series SIMATIC IPC277D
    Display Size 15 inch
    Display Type Widescreen TFT LCD
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Voltage Range 19.2 – 28.8 V DC
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 – 50 °C
    Storage Temperature -20 – 60 °C
    Relative Humidity 5 – 90 % (non-condensing)
    Communication Interfaces 2x PROFINET/Ethernet (RJ45), 4x USB, 1x RS-232/RS-422/RS-485
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 100001
    Loss of communication to the PLC or controller over PROFINET/Ethernet connection.
    Check network cable connections and switch configuration. Verify IP address settings and PROFINET device name assignment. Restart the communication service or reboot the IPC.
    Event ID: 100002
    Runtime software (e.g., WinCC Runtime) has crashed or failed to start.
    Check Windows Event Viewer for application errors. Reinstall or repair the WinCC Runtime installation. Verify that the correct runtime version is licensed and activated.
    Event ID: 100003
    Watchdog timeout detected; the system did not respond within the expected time window.
    Check CPU load and running processes. Reduce background tasks or increase watchdog timeout interval in BIOS or system configuration settings.
    Event ID: 100004
    Internal temperature threshold exceeded; the processor or system board is overheating.
    Ensure adequate ventilation around the panel PC. Check that the panel cutout dimensions meet specifications. Clean any dust from ventilation areas and verify ambient temperature is within rated limits.
    Event ID: 100005
    USB device error or unrecognized USB peripheral connected to the panel PC.
    Disconnect the USB device and reconnect. Try a different USB port. Ensure the USB device driver is installed and compatible with the operating system on the IPC.
    Event ID: 100006
    Storage device (Compact Flash or SSD) read/write error or device not detected.
    Check that the storage medium is properly seated. Replace the Compact Flash card or SSD if it is faulty. Restore the system image from a backup if the operating system partition is corrupted.
    Event ID: 100007
    Power supply voltage out of range; input voltage is below or above the 24 V DC operating threshold.
    Measure the supply voltage at the power connector and confirm it is within 19.2 – 28.8 V DC. Check the power supply unit and wiring for faults.

    Frequently Asked Questions

    What operating system does the SIMATIC IPC277D 6AV7260-0HD40-0CX0 run?

    The IPC277D is typically supplied with Windows Embedded Standard 7 (WES7) or Windows 7 Ultimate, depending on the order configuration. Some variants may also support Windows Embedded POSReady 2009.

    Is the 6AV7260-0HD40-0CX0 compatible with Siemens WinCC Runtime?

    Yes, the SIMATIC IPC277D is fully compatible with Siemens WinCC Runtime and WinCC flexible Runtime, making it suitable for SCADA and HMI visualization applications within the Siemens automation ecosystem.

    What is the input voltage requirement for this panel PC?

    The unit operates on a 24 V DC supply with an acceptable input range of 19.2 to 28.8 V DC.

    What is the front panel protection rating of the IPC277D?

    The front panel of the IPC277D carries an IP65 protection rating, providing full protection against dust ingress and resistance to water jets.

    Can this panel PC communicate with non-Siemens PLCs?

    Yes, the IPC277D supports standard Ethernet and serial communication interfaces, and with appropriate drivers or OPC server software, it can communicate with PLCs and controllers from other manufacturers.

    Troubleshooting

    Display remains blank after power is applied

    Check that the 24 V DC supply voltage is present and within the specified range at the power connector. Verify that the power LED indicator is illuminated. If the LED is on but the display is blank, the backlight or display panel may be faulty.

    Confirm supply voltage is between 19.2 and 28.8 V DC. If voltage is correct and the unit does not boot, attempt a hard reset by cycling power. If the backlight has failed, the display assembly or inverter board may need replacement.

    Touchscreen does not respond or registers incorrect touch positions

    Check whether the touch controller is recognized in Windows Device Manager. Determine if the issue is present across the entire screen or only in specific areas, which may indicate a damaged touch overlay.

    Recalibrate the touchscreen using the Windows touch calibration utility. If calibration does not resolve the issue, check the touch controller ribbon cable connection internally. Replace the touch overlay or resistive touch panel if physically damaged.

    Unit fails to boot into Windows and displays a black screen or error message

    The issue may be caused by a corrupted operating system, a failed storage device, or incorrect BIOS settings. Connect a USB keyboard and attempt to access the BIOS setup to verify boot device order.

    Restore the system image from a Siemens recovery USB or Compact Flash backup. If the storage medium has failed, replace it with a compatible unit and reinstall the operating system and WinCC Runtime software.

    PROFINET or Ethernet communication is intermittent or fails entirely

    Check the Ethernet cable and connector for physical damage. Verify network switch port settings and confirm the IP address and PROFINET device name are correctly configured in the project.

    Replace the Ethernet cable if damaged. Reconfigure the IP address and PROFINET device name using the Siemens Primary Setup Tool or TIA Portal. Check for IP address conflicts on the network.

    Panel PC runs slowly or WinCC Runtime freezes during operation

    High CPU or memory usage may be caused by background Windows processes, antivirus software, or memory leaks in the runtime application. Check Task Manager for resource consumption.

    Disable unnecessary Windows services and background applications. Ensure the WinCC Runtime version is up to date with the latest patches. If the issue persists, consider restoring the factory system image to eliminate software corruption.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart