Siemens 6AV7250-3EC07-0HA0 SIMATIC IPC277D
€ 1.602,00
The Siemens 6AV7250-3EC07-0HA0 is a Panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding automation and process visualization environments. This unit is a 15-inch multi-touch Panel PC that integrates computing power and HMI functionality into a single compact device. It is engineered for use as an operator station in industrial control systems, offering a robust platform for SCADA, HMI, and process visualization applications.
The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 4 simultaneous touch points for intuitive operator interaction. The unit is equipped with an Intel Atom processor and supports Windows Embedded Standard 7 or Windows 7 Ultimate operating systems, providing a familiar computing environment for industrial software. Communication interfaces include multiple USB ports, Ethernet (RJ45), and optional PROFIBUS or PROFINET connectivity, enabling seamless integration into Siemens automation networks. The front panel is rated IP65 for protection against dust and water ingress, making it suitable for harsh industrial environments.
The SIMATIC IPC277D 6AV7250-3EC07-0HA0 is widely deployed in manufacturing, automotive, food and beverage, pharmaceutical, and chemical processing industries. It is commonly used as an operator panel on machine control cabinets, production lines, and process control stations where reliable visualization and operator interaction are required. Its panel-mount design and wide operating temperature range make it suitable for integration directly into control panels on the factory floor.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Type | TFT widescreen |
| Touch Technology | Projected capacitive (PCT) multi-touch, up to 4 touch points |
| Display Resolution | 1024 x 768 px |
| Input Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Processor | Intel Atom |
| Operating System | Windows Embedded Standard 7 / Windows 7 Ultimate |
| Communication Interface | 2x Ethernet RJ45, 4x USB, optional PROFIBUS/PROFINET |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup error — the Panel PC fails to boot correctly into the configured OS.
Check the storage medium (CFast card or HDD) for integrity. Verify BIOS settings and restore OS image if necessary. - Event ID: 200
- Watchdog timeout — the system watchdog has triggered due to an application or OS hang.
Restart the device. Investigate the application causing the hang and update or reconfigure the software. Check for OS resource overload. - Event ID: 300
- Fan failure detected — the internal cooling fan has stopped or is running below the required speed.
Check and clean the fan for obstructions. Replace the fan unit if it is defective to prevent thermal shutdown. - Event ID: 400
- Temperature warning — internal temperature has exceeded the warning threshold.
Check ambient temperature and ensure adequate ventilation around the panel. Clean air filters and verify fan operation. - Event ID: 500
- UPS battery low — the optional uninterruptible power supply module reports low battery capacity.
Replace the UPS battery module. Ensure the UPS is being charged correctly during normal operation. - Event ID: 600
- Ethernet link failure — one or both Ethernet interfaces have lost network connectivity.
Check Ethernet cable connections and switch/router status. Verify network configuration settings in the OS. - Event ID: 700
- Storage medium error — read/write errors detected on the CFast card or hard disk drive.
Back up data immediately. Replace the CFast card or HDD and restore the OS image and application software. - Event ID: 800
- Touch screen calibration error — the PCT touch interface is not responding correctly to input.
Recalibrate the touch screen via the SIMATIC IPC DiagBase or Windows control panel. If the issue persists, check the touch controller hardware.
Frequently Asked Questions
What operating systems are supported by the SIMATIC IPC277D 6AV7250-3EC07-0HA0?
The IPC277D supports Windows Embedded Standard 7 and Windows 7 Ultimate. The specific OS variant depends on the order configuration of the unit.
What is the input voltage for this Panel PC?
The 6AV7250-3EC07-0HA0 operates on 24 V DC supply voltage, which is standard for Siemens industrial panel PCs.
Is the SIMATIC IPC277D compatible with Siemens WinCC and STEP 7 software?
Yes, the IPC277D is fully compatible with Siemens WinCC, WinCC flexible, and STEP 7 software, making it suitable for use as an operator station in Siemens automation environments.
What is the front panel protection rating of this unit?
The front panel of the 6AV7250-3EC07-0HA0 is rated IP65, providing full protection against dust and low-pressure water jets, making it suitable for direct installation in machine control panels.
Can the touch screen support multi-touch gestures?
Yes, the projected capacitive (PCT) touch screen supports up to 4 simultaneous touch points, enabling multi-touch gestures such as pinch-to-zoom for compatible applications.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED indicator is active. Measure voltage at the internal power supply output.
Ensure the 24 V DC supply is within tolerance. If the supply is correct but the display remains blank, the internal power supply or backlight inverter may be faulty and require replacement.
Panel PC does not boot into the operating system
Observe the boot sequence on the display. Check BIOS messages for storage device errors. Verify the CFast card or HDD is correctly seated and recognized in the BIOS.
Reseat the CFast card or HDD. If the storage medium is not detected, replace it and restore the OS image using the Siemens recovery procedure.
Touch screen does not respond or responds inaccurately
Test touch response across the entire screen surface. Check for physical damage or contamination on the screen. Verify touch driver status in the Windows Device Manager.
Clean the screen surface and recalibrate the touch interface via the Windows control panel or SIMATIC IPC DiagBase tool. If the issue persists, the touch controller or digitizer may need replacement.
Network communication lost or intermittent
Check Ethernet cable connections at both the panel and the network switch. Verify IP address configuration in Windows network settings. Test with a known-good cable.
Replace the Ethernet cable if damaged. Reconfigure the IP address settings if incorrect. If the Ethernet port is physically damaged, the unit may require board-level repair.
Unit shuts down unexpectedly or restarts
Check the ambient temperature around the panel and verify fan operation. Review the Windows Event Log for watchdog or thermal events. Check the 24 V DC supply for voltage dips.
Ensure adequate ventilation and that the ambient temperature is within the 0 to 50 °C operating range. Stabilize the power supply. If thermal shutdown is confirmed, clean the fan and heat sink or replace the fan unit.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page