The Siemens 6AV7244-5AA10-0PT0 is a Panel PC belonging to the SIMATIC IPC477D series, manufactured by Siemens as part of its industrial computing portfolio. This unit is a 19-inch industrial panel PC designed for demanding automation and process visualization environments, combining a high-performance computing platform with an integrated operator panel. It is built to meet the rigorous requirements of continuous industrial operation and integrates seamlessly into Siemens automation architectures.
The IPC477D features a 19-inch widescreen TFT display with a resistive touchscreen interface, supporting a resolution of 1280 x 1024 pixels. It is equipped with an Intel Core processor platform, offering substantial processing power for complex SCADA, HMI, and data acquisition tasks. The unit supports multiple communication interfaces including Ethernet (RJ45), USB ports, and optional PROFIBUS or PROFINET connectivity, and is designed for panel mounting with an IP65-rated front face for protection against dust and water ingress. The robust aluminum and steel housing ensures mechanical durability in industrial settings.
The SIMATIC IPC477D is widely deployed in the automotive, chemical, food and beverage, and manufacturing industries, where it serves as a central visualization and control station on the machine or control cabinet front. Its compatibility with Siemens WinCC, STEP 7, and TIA Portal software makes it a natural fit for integration into existing Siemens automation systems. The combination of industrial-grade hardware and flexible software support makes it suitable for both standalone HMI applications and networked SCADA installations.
Technical Specifications
| Display Size | 19 inch |
|---|---|
| Display Resolution | 1280 x 1024 pixels |
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 90 W |
| Front Protection Rating | IP65 |
| Rear Protection Rating | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | 2x Ethernet RJ45, 4x USB, 1x DVI |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC IPC477D |
Common Error Codes & System Events
- Event ID: 100001
- System startup failure — the operating system failed to boot correctly, possibly due to a corrupted system partition or failed storage device.
Check the hard disk or SSD for errors using diagnostic tools. Restore the system image from backup or replace the storage medium if faulty. - Event ID: 100003
- Fan failure detected — the CPU or system cooling fan has stopped or is operating below the minimum speed threshold.
Inspect and clean the fan assembly. Replace the fan if it is not spinning. Ensure adequate ventilation around the unit. - Event ID: 100004
- Temperature warning — internal system temperature has exceeded the defined threshold, risking thermal shutdown.
Check ambient temperature and ensure it is within the specified operating range. Clean air vents and verify fan operation. Reduce heat load if possible. - Event ID: 100005
- Battery low warning — the CMOS/RTC backup battery voltage is below the minimum level, which may cause loss of BIOS settings and real-time clock data.
Replace the internal CMOS battery (typically CR2032) with a compatible replacement. Reset BIOS settings after replacement. - Event ID: 100007
- Watchdog timeout — the system watchdog timer was not reset within the required interval, indicating a software hang or application crash.
Investigate the running application for deadlocks or crashes. Review system logs and restart the application or the panel PC. - Event ID: 100010
- Storage device error — read/write errors detected on the internal hard disk or CompactFlash/SSD storage device.
Run a disk diagnostic utility. Back up data immediately and replace the storage device if errors persist. Restore the system image. - Event ID: 100015
- Network interface error — one or more Ethernet interfaces have lost link or failed to initialize during startup.
Check Ethernet cable connections and switch/hub status. Verify network configuration in the operating system. Replace the cable or network switch port if the fault persists.
Frequently Asked Questions
What operating system does the SIMATIC IPC477D (6AV7244-5AA10-0PT0) run?
The SIMATIC IPC477D is typically supplied with Windows Embedded Standard 7 (WES7) or Windows 7 Professional, depending on the order configuration. The 6AV7244-5AA10-0PT0 variant is configured with a Windows-based operating system suitable for running Siemens WinCC and other SCADA/HMI software.
What is the supply voltage for this panel PC?
The 6AV7244-5AA10-0PT0 operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC industrial panel PCs and compatible with typical industrial control cabinet power supplies.
Is this panel PC compatible with Siemens TIA Portal and WinCC?
Yes, the SIMATIC IPC477D is fully compatible with Siemens TIA Portal and WinCC Runtime software, making it suitable for use as a visualization station within Siemens-based automation systems.
What is the front panel protection rating of this unit?
The front panel of the 6AV7244-5AA10-0PT0 carries an IP65 protection rating, providing complete protection against dust ingress and resistance to water jets, making it suitable for installation in harsh industrial environments.
Can the storage device in this panel PC be replaced or upgraded?
Yes, the SIMATIC IPC477D supports replaceable internal storage. Depending on the configuration, it may use a hard disk drive (HDD) or solid-state drive (SSD), both of which can be replaced or upgraded. Siemens recommends using approved replacement storage devices to ensure compatibility and reliability.
Troubleshooting
Display remains blank after power on
Verify that 24 V DC is present at the power input connector. Check the internal fuse and inspect the backlight inverter or LED driver board. Confirm that the operating system is booting by listening for hard disk activity.
Replace the internal fuse if blown. If the backlight has failed, replace the display assembly or backlight unit. If the OS fails to boot, restore the system image from a backup or replace the storage device.
Touchscreen does not respond or registers incorrect touch positions
Check whether the touch controller driver is correctly installed in the operating system. Inspect the touchscreen surface for damage or contamination. Verify that the resistive touch overlay is not physically damaged or delaminated.
Recalibrate the touchscreen using the Siemens calibration utility or the Windows touch calibration tool. If calibration fails, update or reinstall the touch controller driver. Replace the touchscreen overlay if physical damage is found.
Panel PC freezes or reboots unexpectedly during operation
Check system event logs for watchdog timeout or temperature warning events. Monitor CPU and system temperatures using diagnostic software. Inspect the RAM modules for seating and integrity.
Ensure the operating environment is within the specified temperature range and that cooling vents are unobstructed. Reseat RAM modules. If the issue persists, run a memory diagnostic and replace faulty RAM. Update firmware and drivers to the latest Siemens-approved versions.
Ethernet communication is lost or intermittent
Inspect the RJ45 connectors and cables for damage or poor contact. Check the network switch or hub port status. Verify IP address configuration and network settings in the operating system.
Replace damaged cables or connectors. Reassign a static IP address if DHCP assignment is failing. Update the network adapter driver. If the onboard NIC is faulty, consult Siemens service for motherboard repair or replacement.
BIOS settings reset after each power cycle
This typically indicates a depleted CMOS backup battery. Measure the battery voltage; it should be approximately 3 V DC. A voltage below 2.5 V indicates the battery needs replacement.
Replace the internal CMOS battery (CR2032 or equivalent as specified in the IPC477D service manual). After replacement, re-enter and save the correct BIOS settings including date, time, and boot order.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page