Siemens 6AV7241-7KH18-0FA2 SIMATIC IPC277D
€ 1.995,00
The Siemens 6AV7241-7KH18-0FA2 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding automation and process visualization environments. This unit is a 19-inch multi-touch panel PC that integrates computing power and HMI functionality into a single compact device. It is designed for front-panel mounting and provides a robust platform for SCADA, HMI, and process control applications.
The IPC277D features a 19-inch widescreen TFT display with a projected capacitive (PCAP) multi-touch interface, supporting up to 4 simultaneous touch points for intuitive operator interaction. The unit is powered by an Intel Atom processor and runs Microsoft Windows Embedded Standard 7 or Windows 7 Ultimate, providing compatibility with standard industrial software packages including WinCC and WinCC flexible. It offers multiple communication interfaces including Ethernet (RJ45), USB ports, and optionally PROFIBUS or PROFINET, enabling seamless integration into Siemens automation networks. The device is built to IP65 protection rating on the front panel, making it resistant to dust and water ingress in industrial environments.
The SIMATIC IPC277D is widely deployed in manufacturing, automotive, food and beverage, chemical, and pharmaceutical industries where a reliable and powerful HMI platform is required. It is particularly suited for applications demanding high graphical performance, multi-touch operation, and integration with Siemens SIMATIC controllers such as the S7-300, S7-400, and S7-1500 series. Its fanless design options and robust construction make it appropriate for environments with high levels of vibration, dust, and temperature variation.
Technical Specifications
| Display Size | 19 inch |
|---|---|
| Display Technology | TFT LCD |
| Touch Technology | Projected Capacitive (PCAP) Multi-Touch |
| Touch Points | 4 simultaneous |
| Display Resolution | 1280 x 1024 px (SXGA) |
| Processor | Intel Atom E3827 (dual-core) |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| Communication Interface | 2x Ethernet RJ45, 4x USB, 1x DisplayPort |
| Operating System | Windows 7 Ultimate / Windows Embedded Standard 7 |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5 % to 90 % (non-condensing) |
| Mounting | Front panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC IPC277D |
Common Error Codes & System Events
- Event ID: 1000
- Application error or crash reported by Windows Event Log, typically caused by a software fault or incompatible driver.
Check Windows Event Viewer for details. Update or reinstall the affected application or driver. Ensure OS and software patches are up to date. - Event ID: 41
- System was shut down unexpectedly without a clean shutdown, often caused by power loss or hardware fault.
Check the 24 V DC power supply for stability and correct voltage. Inspect power connectors and UPS configuration if applicable. - BIOS POST Error
- Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
Reseat RAM modules and storage devices. Check BIOS settings. Replace faulty hardware components if POST error persists. - Watchdog Timeout
- The system watchdog timer has expired, indicating the operating system or application has become unresponsive.
Investigate software causing the hang. Adjust watchdog timer settings in BIOS or application configuration. Check for memory or CPU overload. - Fan Failure Warning
- Cooling fan has stopped or is operating below the required speed threshold (on units with active cooling).
Clean or replace the cooling fan. Ensure ventilation clearances around the device are maintained per installation guidelines. - Storage Device Error
- The internal storage medium (SSD or CFast card) has reported a read/write error or is not detected.
Check storage device seating and connections. Replace the CFast card or SSD. Restore the OS image from backup media. - Temperature Warning
- Internal temperature sensor has exceeded the warning threshold, risking thermal shutdown.
Check ambient temperature and ensure it is within the 0–50 °C operating range. Clean air vents and verify cooling system operation.
Frequently Asked Questions
What operating systems are supported by the SIMATIC IPC277D (6AV7241-7KH18-0FA2)?
The IPC277D supports Windows 7 Ultimate and Windows Embedded Standard 7. Depending on the variant, Windows 10 IoT Enterprise may also be available as an upgrade option.
What is the display size and touch technology used in this unit?
This unit features a 19-inch TFT display with projected capacitive (PCAP) multi-touch technology, supporting up to 4 simultaneous touch points.
Is the 6AV7241-7KH18-0FA2 compatible with Siemens WinCC?
Yes, the SIMATIC IPC277D is fully compatible with Siemens WinCC and WinCC flexible runtime software, making it a standard platform for Siemens SCADA and HMI applications.
What is the front panel protection rating of this panel PC?
The front panel of the IPC277D carries an IP65 protection rating, providing full protection against dust and resistance to water jets.
What communication interfaces are available on this device?
The unit provides two Ethernet RJ45 ports, four USB ports, and a DisplayPort. Optional PROFIBUS or PROFINET interfaces may be available depending on the configuration.
Troubleshooting
Display remains blank after power on
Check the 24 V DC supply voltage at the power connector. Verify that the power LED is illuminated. Measure voltage at the internal power supply output.
Ensure the 24 V DC supply is within tolerance. Replace the internal power supply board if no output voltage is detected. If the supply is correct, the display backlight inverter or display panel may require replacement.
Touch input is unresponsive or inaccurate
Check for physical damage or contamination on the touch surface. Verify touch driver installation in Device Manager. Test with a known-good stylus or finger.
Clean the touch surface with a lint-free cloth. Reinstall or update the PCAP touch controller driver. If the issue persists, the touch controller board may need replacement.
System fails to boot and shows BIOS error
Attempt to enter BIOS setup on startup. Check if the storage device (CFast or SSD) is detected. Inspect RAM seating.
Reseat the storage device and RAM. If the storage device is not detected, replace the CFast card or SSD and restore the OS image from a backup or Siemens recovery media.
Device overheats and shuts down unexpectedly
Monitor internal temperature via BIOS or Siemens SIMATIC IPC DiagMonitor software. Check ambient temperature and ventilation clearances around the panel cutout.
Ensure ambient temperature does not exceed 50 °C. Clean any dust from ventilation slots. Verify that the minimum clearance distances specified in the installation manual are maintained.
Ethernet communication is not established
Check physical cable connections on both RJ45 ports. Verify network configuration (IP address, subnet mask) in Windows Network Settings. Test with a known-good cable.
Replace the Ethernet cable. Reconfigure the network adapter settings. If the adapter is not detected in Device Manager, update the network driver or replace the mainboard if the port is physically damaged.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BA01-4AX0 TP177B
€ 675,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page