• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7241-3BC04-0FA0 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7241-3BC04-0FA0 SIMATIC IPC277D

    € 1.957,00

    Reset
    Clear
    SKU: 6AV7241-3BC04-0FA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7241-3BC04-0FA0 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding automation and process visualization environments. This unit is a 15-inch multi-touch panel PC that integrates computing power and HMI functionality into a single compact device. It is designed for front-panel mounting and offers a robust, fanless design suitable for continuous industrial operation.

    The IPC277D features a projected capacitive (PCT) multi-touch display with a resolution of 1024 x 768 pixels and supports Windows Embedded Standard 7 or Windows 7 Ultimate operating systems. It is equipped with an Intel Atom processor and offers multiple communication interfaces including PROFINET, USB, and Ethernet ports, enabling seamless integration into Siemens TIA Portal environments. The unit supports SIMATIC WinCC Runtime software and is built to IEC 61131 standards, with a protection rating of IP65 on the front panel, making it resistant to dust and water ingress.

    The SIMATIC IPC277D is widely deployed in manufacturing automation, process control, and machine visualization applications across industries such as automotive, food and beverage, pharmaceuticals, and chemical processing. Its multi-touch capability and industrial-grade construction make it suitable for use as an operator station on production lines, packaging machines, and process control panels. The integration with Siemens TIA Portal and WinCC Runtime simplifies engineering and commissioning in Siemens-based automation architectures.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Touch Technology Projected Capacitive (PCT) Multi-Touch
    Display Colors 16.7 million colors
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 60 W
    Processor Intel Atom E3827, 1.75 GHz
    Memory (RAM) 2 GB DDR3
    Storage 2 GB CFast (onboard)
    Operating System Windows Embedded Standard 7 (WES7)
    Communication Interface 2x PROFINET/Ethernet RJ45, 4x USB 2.0, 1x USB 3.0
    IP/Protection Rating IP65 (front panel)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    Mounting Front panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC IPC277D

    Common Error Codes and System Events

    Event ID: 100
    Operating system startup error or boot failure detected during POST sequence.
    Check storage medium (CFast card) for integrity. Verify BIOS settings and re-seat the CFast card. Replace CFast card if corrupted.
    Event ID: 1000
    Application crash or unexpected software termination in WinCC Runtime or user application.
    Review Windows Event Viewer logs for faulting module. Reinstall or update WinCC Runtime. Check for memory or storage issues.
    Event ID: 6008
    Unexpected system shutdown recorded by Windows Event Log, indicating a previous unclean shutdown.
    Check 24 V DC power supply stability. Verify UPS or power conditioning. Inspect power connector and wiring for intermittent contact.
    Touch Error
    Touch input unresponsive or erratic, PCT touch controller not recognized by the operating system.
    Recalibrate the touch screen via the Siemens Touch Screen Configurator tool. Update touch controller drivers. Clean the display surface and check for electromagnetic interference sources nearby.
    PROFINET Communication Error
    Loss of PROFINET communication between the IPC277D and connected controllers or network devices.
    Check Ethernet cable connections and RJ45 connectors. Verify IP address configuration and network settings in TIA Portal. Check for duplicate IP addresses on the network.
    Overtemperature Warning
    Internal temperature of the panel PC has exceeded the permissible operating threshold.
    Verify ambient temperature is within 0 °C to +50 °C. Ensure adequate ventilation around the unit. Check that ventilation slots are not obstructed. Inspect thermal interface materials if unit has been serviced.
    WinCC Runtime Startup Failure
    WinCC Runtime application fails to start or displays a license error on boot.
    Verify that a valid WinCC Runtime license is installed and not expired. Check the Siemens Automation License Manager (ALM). Reinstall WinCC Runtime if license is valid but application still fails to launch.
    Storage Medium Error
    CFast card or connected storage device is not detected or reports read/write errors.
    Re-seat the CFast card in its slot. Test the CFast card in another device. Replace the CFast card with a Siemens-approved industrial-grade CFast card if defective.

    Frequently Asked Questions

    What operating systems are supported by the SIMATIC IPC277D 6AV7241-3BC04-0FA0?

    This unit supports Windows Embedded Standard 7 (WES7) as its primary operating system. Windows 7 Ultimate is also available depending on the order configuration.

    What is the touch technology used on this panel PC?

    The 6AV7241-3BC04-0FA0 uses Projected Capacitive (PCT) multi-touch technology, supporting simultaneous multi-touch input for intuitive operator interaction.

    Is this panel PC compatible with Siemens TIA Portal and WinCC Runtime?

    Yes, the SIMATIC IPC277D is fully compatible with Siemens TIA Portal engineering software and supports WinCC Runtime for visualization and SCADA applications.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV7241-3BC04-0FA0 is rated IP65, providing complete protection against dust ingress and protection against low-pressure water jets.

    What communication interfaces are available on this panel PC?

    The unit provides two PROFINET/Industrial Ethernet RJ45 ports, four USB 2.0 ports, and one USB 3.0 port, enabling connectivity to PLCs, network infrastructure, and peripheral devices.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector. Check that the voltage is within the permissible range. Inspect the internal fuse and power supply board for damage.

    Restore the 24 V DC supply to within specification. Replace the internal fuse if blown. If the power supply board is faulty, replace the unit or the internal power supply module.

    Touch screen does not respond to input

    Verify that the touch controller is recognized in Windows Device Manager. Check for any error flags on the touch controller driver. Clean the screen surface and remove any conductive contaminants.

    Recalibrate the touch screen using the Siemens Touch Screen Configurator utility. Update or reinstall the touch controller driver. If hardware failure is confirmed, replace the touch screen assembly.

    Unit fails to boot and displays a black screen with BIOS error

    Check the CFast card seating and integrity. Enter BIOS setup to verify boot device order and storage detection. Listen for POST beep codes indicating hardware faults.

    Re-seat or replace the CFast card with a Siemens-approved industrial CFast card. Restore BIOS settings to factory defaults if misconfigured. If the mainboard is faulty, replace the mainboard or the complete unit.

    PROFINET communication is intermittent or lost

    Check the Ethernet cable and RJ45 connector for physical damage or poor contact. Verify IP address settings and subnet configuration. Use TIA Portal diagnostics to identify communication faults.

    Replace damaged cables or connectors. Correct IP address conflicts on the network. Update the PROFINET driver or firmware if a software-related communication issue is identified.

    WinCC Runtime crashes repeatedly after startup

    Review the Windows Event Viewer Application log for error codes related to WinCC Runtime. Check available storage space on the CFast card and verify license validity in the Automation License Manager.

    Free up storage space or replace the CFast card if near capacity. Reinstall WinCC Runtime software. Reactivate or transfer the WinCC Runtime license using the Siemens Automation License Manager.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6640-0CA01-0AX0 OP 73micro

      Siemens 6AV6640-0CA01-0AX0 OP 73micro

      € 279,00 – € 444,13Price range: € 279,00 through € 444,13
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart