• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV7241-3BB04-0JA7 SIMATIC IPC277D
    Awaiting product image

    Siemens 6AV7241-3BB04-0JA7 SIMATIC IPC277D

    € 1.477,00

    Reset
    Clear
    SKU: 6AV7241-3BB04-0JA7 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV7241-3BB04-0JA7 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial-grade embedded panel PC lineup. It is designed for use as a human-machine interface (HMI) and industrial computing platform, combining a touchscreen display with an embedded PC architecture. This unit is built to meet the demanding requirements of industrial environments, offering robust performance in a compact panel-mount form factor.

    The IPC277D features a widescreen display with a resistive or projected capacitive touch interface, depending on the variant, and runs on an Intel Atom processor with Windows Embedded Standard or Windows Embedded 7 as the operating system. It is equipped with CompactFlash or SSD storage options, USB ports, and Ethernet interfaces for connectivity to SCADA systems, PLCs, and plant networks. The unit supports PROFINET communication and is compatible with Siemens WinCC and other SIMATIC HMI software packages, enabling seamless integration into Siemens automation architectures.

    The SIMATIC IPC277D is widely deployed in manufacturing, process automation, and machine building applications where a reliable, panel-integrated computing solution is required. It is suitable for use in automotive assembly lines, food and beverage processing, pharmaceutical production, and water treatment facilities. Its fanless design options and wide operating temperature range make it appropriate for environments where maintenance access is limited and continuous operation is critical.

    Technical Specifications

    Series SIMATIC IPC277D
    Display Size 15 inch widescreen
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 5% to 90% (non-condensing)
    IP Rating (Front) IP65
    Communication Interface 2x RJ45 Ethernet (PROFINET), 4x USB 2.0, 1x RS-232
    Processor Intel Atom E3827 dual-core
    RAM 2 GB DDR3
    Storage CompactFlash or SSD
    Operating System Windows Embedded Standard 7
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 100
    System startup failure or boot error detected during POST sequence.
    Check power supply voltage at 24 V DC input. Verify storage medium (CompactFlash/SSD) is properly seated and not corrupted. Attempt system restore or OS reinstallation.
    Event ID: 1000
    Application crash or unexpected software termination reported by Windows Event Log.
    Review Windows Event Viewer for detailed error logs. Update or reinstall the affected application. Check for memory or storage faults.
    Event ID: 6008
    Unexpected system shutdown recorded by the operating system.
    Check for power supply instability or undervoltage at the 24 V DC input. Inspect for overheating conditions and verify ventilation around the unit.
    Communication Error
    Loss of PROFINET or Ethernet communication with connected PLC or network devices.
    Verify Ethernet cable connections and switch/hub status. Check IP address configuration and PROFINET device name assignment. Inspect network settings in WinCC or the HMI project.
    Touchscreen Not Responding
    Touch input is not registered or is inaccurate on the display surface.
    Perform touchscreen recalibration via the Windows control panel or SIMATIC HMI settings. Clean the touch surface. If the issue persists, inspect the touch controller ribbon cable connection internally.
    Storage Medium Error
    CompactFlash or SSD storage device is not detected or reports read/write errors.
    Reseat the CompactFlash card or SSD. Test the storage medium in another device. Replace the storage medium if faulty and restore the OS image using Siemens recovery tools.
    Watchdog Timeout
    Hardware watchdog timer has triggered a system reset due to software hang or unresponsive OS.
    Investigate the application or OS process causing the hang. Update firmware and software to the latest Siemens-recommended versions. Check for resource overload (CPU or RAM usage).

    Frequently Asked Questions

    What operating system does the SIMATIC IPC277D 6AV7241-3BB04-0JA7 run?

    This unit runs Windows Embedded Standard 7, which is pre-installed and optimized for industrial HMI applications including Siemens WinCC Runtime.

    What communication interfaces are available on this panel PC?

    The IPC277D provides two RJ45 Ethernet ports supporting PROFINET, four USB 2.0 ports, and one RS-232 serial interface for connectivity to PLCs, networks, and peripherals.

    Is this panel PC compatible with Siemens WinCC software?

    Yes, the SIMATIC IPC277D is fully compatible with Siemens WinCC Runtime and WinCC flexible Runtime, making it suitable for integration into SIMATIC automation projects.

    What is the supply voltage for this unit?

    The 6AV7241-3BB04-0JA7 operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC panel PCs.

    What is the front panel protection rating of this device?

    The front panel of the IPC277D achieves an IP65 protection rating, making it resistant to dust ingress and low-pressure water jets, suitable for industrial panel installation.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power input connector. Check the internal fuse and verify the power LED status on the unit.

    Restore correct supply voltage within the 24 V DC nominal range. Replace the internal fuse if blown. If the backlight is faulty, the display assembly may require replacement.

    Touchscreen input is inaccurate or unresponsive

    Determine whether the issue is a calibration problem or a hardware fault by attempting recalibration. Check for physical damage or contamination on the touch surface.

    Recalibrate the touchscreen via Windows Control Panel under Tablet PC Settings. Clean the screen surface. If recalibration fails, inspect the internal touch controller connection or replace the touch overlay.

    Unit fails to boot or repeatedly restarts

    Check the 24 V DC supply for voltage drops or instability. Inspect the CompactFlash or SSD for corruption by connecting it to an external reader.

    Stabilize the power supply. Replace or reformat the storage medium and restore the OS image using the Siemens recovery partition or a factory image backup.

    Loss of communication with PLC via PROFINET

    Verify physical Ethernet cable connections and check the network switch. Confirm the IP address and PROFINET device name are correctly configured in the HMI project and on the PLC.

    Correct IP address conflicts or PROFINET name mismatches. Replace faulty Ethernet cables. Ensure the PROFINET driver and WinCC project configuration match the PLC's expected device parameters.

    System runs slowly or HMI application freezes

    Monitor CPU and RAM usage via Windows Task Manager. Check for background processes consuming excessive resources or for storage medium read/write errors.

    Close unnecessary background applications and disable non-essential startup programs. If the storage medium is degraded, replace it with a new CompactFlash card or SSD and restore the system image.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart