Siemens 6AV7241-1WA05-0FA0 SIMATIC IPC277D
€ 1.373,00
The Siemens 6AV7241-1WA05-0FA0 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial-grade embedded panel PC lineup. It is designed for demanding human-machine interface applications requiring a robust, fanless computing platform integrated with a touchscreen display. This unit combines the functionality of an industrial PC with a flat-panel operator interface in a single compact enclosure.
The IPC277D features a widescreen display with a resistive or projected capacitive touch interface, depending on the variant, and is built around an Intel Atom processor platform for reliable embedded operation. It supports communication via standard interfaces including USB, Ethernet (RJ45), and optionally PROFINET, enabling seamless integration into Siemens TIA Portal-based automation environments. The unit runs Windows Embedded Standard 7 or compatible embedded operating systems, and its fanless, diskless design using CompactFlash or onboard flash storage ensures high reliability in continuous industrial operation. The front panel meets IP65 protection rating, making it resistant to dust and water ingress from the front.
The SIMATIC IPC277D 6AV7241-1WA05-0FA0 is widely used in machine building, process automation, and factory automation applications where a panel-mounted operator station with PC functionality is required. It is suitable for industries such as automotive manufacturing, food and beverage processing, pharmaceutical production, and general industrial machinery. Its compatibility with Siemens WinCC and TIA Portal software makes it a natural fit for installations already using Siemens SIMATIC control systems.
Technical Specifications
| Series | SIMATIC IPC277D |
|---|---|
| Display Size | 15 in (widescreen) |
| Touch Technology | Resistive touchscreen |
| Processor | Intel Atom E3827 (dual-core) |
| Input/Operating Voltage | 24 V DC |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front panel) |
| Communication Interface | 2x Ethernet RJ45 (10/100/1000 Mbit/s), 4x USB 2.0 |
| Storage | CompactFlash / onboard flash |
| Operating System | Windows Embedded Standard 7 |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST.
Check storage medium (CompactFlash card) for errors or corruption. Re-image the operating system if necessary. - Event ID: 1000
- Application crash or unexpected software termination recorded in Windows Event Log.
Review Windows Event Viewer for faulting module details. Reinstall or update the affected application or runtime environment. - Event ID: 6008
- Unexpected system shutdown recorded by Windows Event Log, indicating a previous unclean shutdown.
Check 24 V DC power supply stability. Inspect power connections and ensure supply voltage is within tolerance. Check for thermal shutdown events. - Hardware Error: POST Fail
- Power-On Self-Test failure detected at startup, indicating a hardware component fault.
Disconnect all peripherals and retry. If fault persists, check RAM seating and CompactFlash card. Contact Siemens service if hardware fault is confirmed. - Network Error: Link Down
- Ethernet interface reports no link, indicating a communication loss on one or both network ports.
Check Ethernet cable connections and switch/hub status. Verify network configuration in Windows Device Manager. Replace cable or check port on network switch. - Watchdog Timeout
- Hardware watchdog timer has triggered a system reset due to software hang or unresponsive application.
Investigate application causing the hang. Update or reconfigure the watchdog-monitored software. Check for memory leaks or CPU overload conditions. - Temperature Warning
- Internal temperature sensor reports operating temperature approaching or exceeding the specified limit.
Check ambient temperature around the panel PC. Ensure adequate ventilation in the control cabinet. Clean any dust from the enclosure vents and verify cooling provisions.
Frequently Asked Questions
What operating system does the SIMATIC IPC277D 6AV7241-1WA05-0FA0 run?
This unit runs Windows Embedded Standard 7 (WES7) as its operating system, which is pre-installed on the CompactFlash or onboard flash storage.
What is the supply voltage for this panel PC?
The IPC277D 6AV7241-1WA05-0FA0 operates on a 24 V DC supply voltage, which is standard for Siemens SIMATIC panel devices.
Is this panel PC compatible with Siemens TIA Portal and WinCC?
Yes, the SIMATIC IPC277D is compatible with Siemens WinCC Runtime and TIA Portal-based SCADA and HMI software, making it suitable for integration into SIMATIC automation environments.
What is the front panel protection rating of this unit?
The front panel of the IPC277D meets IP65 protection, providing full dust protection and protection against water jets from any direction.
Can the storage medium be replaced or upgraded?
The unit uses a CompactFlash card or onboard flash for storage, which can typically be replaced or re-imaged. Refer to the Siemens SIMATIC IPC277D operating instructions for the correct procedure and approved storage media.
Troubleshooting
Display remains blank after power is applied
Measure 24 V DC at the power supply connector. Check the internal fuse and verify the power LED status on the unit.
Ensure the 24 V DC supply is within tolerance (typically 18–30 V DC). Replace the internal fuse if blown. If the backlight has failed, the display assembly may require replacement.
Touchscreen does not respond to input
Check if the operating system has fully booted by connecting an external USB mouse or keyboard. Verify touch driver status in Windows Device Manager.
Recalibrate the touchscreen via the Windows control panel touch settings. If the touch controller is not recognized, reinstall the touch driver from the Siemens recovery image or support portal.
Unit fails to boot and shows a POST error or blank screen with no OS loading
Remove and inspect the CompactFlash card for physical damage or corruption. Attempt to boot from an external USB device if supported.
Re-image the CompactFlash card with the correct Siemens recovery image for this unit. Replace the CompactFlash card if it is physically damaged or unreadable.
Ethernet communication is not established with the PLC or network
Check the RJ45 port LEDs for link activity. Verify IP address configuration in Windows Network and Sharing Center. Test with a known-good cable.
Reconfigure the IP address settings to match the network subnet. Replace the Ethernet cable. If the port LEDs show no activity with a known-good cable, the NIC may require service.
System reboots unexpectedly or triggers watchdog resets
Review Windows Event Viewer for critical errors or watchdog timeout events. Monitor CPU and memory usage during operation to identify resource exhaustion.
Identify and terminate any runaway processes consuming excessive CPU or memory. Ensure the HMI runtime application is correctly configured. Verify that the 24 V DC power supply is stable and free from voltage dips.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page