Siemens 6AV7240-8KB07-0KA2 SIMATIC IPC277D
€ 1.995,00
The Siemens 6AV7240-8KB07-0KA2 is a panel PC belonging to the SIMATIC IPC277D series, part of Siemens' industrial PC product line designed for demanding human-machine interface applications. This unit is a 15-inch widescreen industrial panel PC that integrates computing performance with a robust touchscreen display in a single compact housing. It is designed for direct panel mounting and operates within the SIMATIC industrial PC ecosystem, making it compatible with Siemens automation software and hardware environments.
The IPC277D features a resistive or projected capacitive touchscreen with a 15.6-inch widescreen TFT display offering a resolution of 1366 x 768 pixels. It is powered by an Intel Atom or Celeron processor depending on the configuration variant and supports Windows Embedded Standard 7 or Windows 7 operating systems. The unit provides communication interfaces including USB ports, Ethernet (RJ45), and optionally PROFINET, and is built to an IP65 protection rating on the front panel for resistance to dust and water ingress. It operates on a 24 V DC supply and is designed for fanless operation in many configurations, reducing maintenance requirements.
The SIMATIC IPC277D is widely deployed in manufacturing automation, process control, and machine tool applications where a robust, panel-mounted HMI with PC functionality is required. It is suitable for use in the automotive, food and beverage, pharmaceutical, and general manufacturing industries. Its compatibility with SIMATIC WinCC, WinCC flexible, and other Siemens SCADA and visualization software makes it a practical choice for operators requiring integrated visualization and control on the factory floor.
Technical Specifications
| Display Size | 15.6 inch (widescreen) |
|---|---|
| Display Resolution | 1366 x 768 pixels |
| Display Type | TFT LCD |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| IP Protection Rating (Front) | IP65 |
| IP Protection Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | 2x RJ45 Ethernet, 4x USB |
| Mounting | Panel mounting |
| Series/Product Family | SIMATIC IPC277D |
| Certifications | CE, UL, cULus |
Common Error Codes & System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check storage media (SSD/HDD) integrity, verify BIOS settings, and attempt system restore or OS reinstallation if the drive is faulty. - Event ID: 200
- Overtemperature condition detected; internal temperature has exceeded the permissible operating limit.
Check ambient temperature, clean ventilation openings, verify cooling system operation, and ensure the panel cutout provides adequate airflow. - Event ID: 300
- Watchdog timeout triggered; the application software has stopped responding within the defined watchdog interval.
Restart the application software. If the fault persists, check for software deadlocks, update the application, or reinstall the operating system. - Event ID: 400
- Ethernet communication link failure; no network connection detected on one or both RJ45 ports.
Inspect Ethernet cables and connectors, verify switch or network device status, and check network adapter settings within the operating system. - Event ID: 500
- USB device error; a connected USB peripheral has caused a device enumeration or communication fault.
Disconnect and reconnect the USB device. Try an alternative USB port. Update USB drivers or replace the faulty peripheral device. - Event ID: 600
- Power supply undervoltage; the 24 V DC supply voltage has dropped below the permissible minimum threshold.
Measure the supply voltage at the power connector. Ensure the power supply unit is rated for the load and check wiring for excessive voltage drop. - Event ID: 700
- Touchscreen calibration error or touch input not responding correctly.
Recalibrate the touchscreen via the operating system control panel. If the issue persists, check the touchscreen controller driver and replace the touch overlay if damaged.
Frequently Asked Questions
What is the supply voltage for the Siemens 6AV7240-8KB07-0KA2?
The unit operates on a 24 V DC supply voltage. Ensure the power source is stable and within the permissible voltage tolerance range.
What is the IP protection rating of this panel PC?
The front panel of the IPC277D achieves IP65 protection, making it resistant to dust and water jets. The rear of the unit is rated IP20.
Is this panel PC compatible with Siemens WinCC visualization software?
Yes, the SIMATIC IPC277D is compatible with SIMATIC WinCC, WinCC flexible, and other Siemens HMI and SCADA software packages, as it runs a Windows-based operating system.
What communication interfaces are available on this unit?
The 6AV7240-8KB07-0KA2 provides dual RJ45 Ethernet ports and multiple USB ports. Additional interfaces may be available depending on the installed option cards.
What mounting method is used for this panel PC?
The IPC277D is designed for panel mounting, installed into a cutout in a control cabinet door or operator panel and secured with mounting clamps from the rear.
Troubleshooting
Display remains blank after power is applied
Measure the 24 V DC supply voltage at the power connector. Check the internal fuse and verify that the power LED indicator is illuminated.
Restore the supply voltage to within specification. Replace the internal fuse if blown. If the display backlight has failed, the backlight inverter or display assembly may require replacement.
Touchscreen does not respond to touch input
Verify that the touchscreen driver is correctly installed within the operating system. Check Device Manager for any driver errors related to the touch controller.
Reinstall or update the touchscreen driver. Recalibrate the touchscreen through the operating system settings. If hardware damage is suspected, replace the touch overlay or the complete display assembly.
Unit fails to boot and displays a POST error or blank screen on startup
Check the SSD or HDD for errors using diagnostic tools. Verify BIOS settings are correct and that the boot device is properly detected.
Restore BIOS to default settings. If the storage device is faulty, replace the SSD or HDD and reinstall the operating system using the Siemens recovery media.
Ethernet communication is intermittent or not functioning
Inspect the RJ45 connectors and cables for damage. Check the network adapter status in the operating system Device Manager and verify IP configuration settings.
Replace damaged cables or connectors. Update the network adapter driver. If the onboard Ethernet port is faulty, an external USB-to-Ethernet adapter may be used as a temporary measure.
Unit overheats and shuts down unexpectedly
Check the ambient temperature around the panel PC. Inspect ventilation openings for blockages caused by dust or debris. Verify that the panel cutout dimensions meet Siemens installation requirements.
Clean all ventilation openings with compressed air. Reduce the ambient temperature by improving cabinet ventilation or adding cooling. Ensure the installation complies with the minimum clearance dimensions specified in the IPC277D operating instructions.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900
€ 1.340,00Select options This product has multiple variants. The options may be chosen on the product page