Siemens 6AV7240-0AB04-0CA0 SIMATIC IPC277D
€ 1.260,00
The Siemens 6AV7240-0AB04-0CA0 is a Panel PC belonging to the SIMATIC IPC277D series, manufactured by Siemens as part of its industrial computing portfolio. This unit is a 15-inch multi-touch panel PC designed for demanding industrial environments, combining HMI functionality with PC-based computing power in a single compact device. It is built to operate reliably in harsh industrial conditions and integrates seamlessly into Siemens automation architectures.
The IPC277D features a 15-inch widescreen TFT display with a projected capacitive (PCT) multi-touch interface, supporting up to 5 simultaneous touch points for intuitive operator interaction. The unit is equipped with an Intel Atom processor, onboard RAM, and solid-state storage options, providing sufficient computing performance for SCADA, visualization, and process control applications. Communication interfaces include multiple USB ports, Ethernet (RJ45), and optional PROFIBUS or PROFINET connectivity, enabling integration into existing plant networks. The device carries an IP65 rating on the front panel, protecting against dust and water ingress in industrial settings.
The SIMATIC IPC277D is widely deployed in manufacturing, automotive, food and beverage, pharmaceutical, and process industries where robust panel PCs are required at the machine level. It is suitable for use as an operator station running WinCC, SIMATIC WinCC flexible, or third-party SCADA software. Its fanless design options and wide operating temperature range make it particularly appropriate for environments where maintenance access is limited and continuous operation is critical.
Technical Specifications
| Display Size | 15 inch |
|---|---|
| Display Technology | TFT LCD |
| Touch Technology | Projected Capacitive (PCT) Multi-Touch, up to 5 touch points |
| Display Resolution | 1024 x 768 px (XGA) |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | Approx. 60 W |
| IP/Protection Rating | IP65 (front panel) |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 5% to 90% (non-condensing) |
| Communication Interface | 2x RJ45 Ethernet, 4x USB, optional PROFIBUS/PROFINET |
| Processor | Intel Atom |
| Mounting | Panel mounting (portrait or landscape) |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC IPC277D |
Common Error Codes and System Events
- Event ID: 100
- Operating system startup failure or boot error detected during POST sequence.
Check storage device integrity, verify BIOS settings, and attempt system restore or OS reinstallation. - Event ID: 1000
- Application crash or unexpected termination of the HMI runtime software (e.g., WinCC).
Review Windows Event Viewer logs, update or reinstall the HMI runtime software, and check for memory or storage faults. - Event ID: 7000
- Service failed to start during Windows boot, potentially affecting HMI or communication services.
Check Windows Services configuration, ensure all required drivers and runtime components are installed correctly. - Event ID: 7036
- A system service entered a stopped state unexpectedly, which may interrupt HMI communication or data logging.
Identify the affected service via Event Viewer, restart the service manually, and investigate root cause such as driver conflicts. - BIOS POST Error
- Hardware component not detected during Power-On Self-Test, such as missing RAM or storage device.
Reseat RAM modules and storage devices, verify hardware connections, and replace faulty components if not detected after reseating. - WinCC Runtime Error
- WinCC runtime fails to establish connection to PLC or SCADA server, resulting in communication loss alarm.
Verify Ethernet cable connections, check IP address configuration, confirm PLC is online, and review WinCC connection parameters. - Temperature Warning
- Internal temperature of the IPC has exceeded the recommended operating threshold.
Check ambient temperature, ensure adequate ventilation around the panel cutout, clean any dust from vents, and verify cooling components are functional.
Frequently Asked Questions
What is the display size and touch technology of the 6AV7240-0AB04-0CA0?
This unit features a 15-inch TFT LCD display with projected capacitive (PCT) multi-touch technology supporting up to 5 simultaneous touch points.
What operating voltage does the SIMATIC IPC277D require?
The IPC277D operates on 24 V DC power supply, which is standard for Siemens industrial panel PCs.
Is the 6AV7240-0AB04-0CA0 compatible with Siemens WinCC software?
Yes, this panel PC is designed to run Siemens WinCC, WinCC flexible, and other compatible SCADA or HMI runtime software on its Windows-based operating system.
What is the front panel protection rating of this device?
The front panel of the IPC277D carries an IP65 rating, providing full protection against dust ingress and protection against low-pressure water jets.
Can this panel PC be used in a fanless configuration?
The IPC277D series offers fanless design variants depending on the processor and configuration selected, making it suitable for low-maintenance environments.
Troubleshooting
Display remains blank after power is applied
Measure 24 V DC supply voltage at the power connector. Check the internal fuse and verify the power supply unit output.
Restore correct supply voltage within the 24 V DC specification. Replace the internal fuse if blown, or replace the power supply module if voltage output is absent.
Touch input is unresponsive or inaccurate
Check for physical damage or contamination on the touch surface. Verify touch driver installation in the Windows Device Manager.
Clean the touch surface with a soft, dry cloth. Recalibrate the touch screen via the Windows control panel or Siemens touch calibration utility. Reinstall touch drivers if the device is not recognized.
HMI runtime software fails to start or crashes repeatedly
Review Windows Event Viewer for application error logs. Check available storage space and RAM utilization.
Free up disk space, repair or reinstall the HMI runtime software, and ensure all Windows updates and runtime patches are applied. Replace storage media if disk errors are detected.
No communication with PLC or network devices
Verify Ethernet cable connections and check IP address configuration in Windows Network Settings. Ping the target PLC from the panel PC to confirm network reachability.
Correct IP address or subnet configuration, replace faulty Ethernet cables, and verify PLC communication settings match those configured in the HMI project.
Device overheating or thermal shutdown occurs
Check ambient temperature at the installation location. Inspect the panel cutout dimensions and clearances against Siemens installation guidelines.
Ensure adequate ventilation around the device, reduce ambient temperature if possible, and verify that the panel cutout meets the minimum size and clearance requirements specified in the IPC277D operating instructions.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-0BA01-1AX1 TP177B
€ 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page