Siemens 6AV6648-0BE11-3AX0 SIMATIC KTP400 Basic
€ 722,00
The Siemens 6AV6648-0BE11-3AX0 is a SIMATIC KTP400 Basic panel belonging to the Basic Panel 2nd Generation family from Siemens. It is a compact 4-inch key and touch-operated HMI panel designed for straightforward visualization and operator control tasks. The unit is configured using the SIMATIC WinCC Basic engineering software, which is included with SIMATIC STEP 7 Basic and TIA Portal.
The KTP400 Basic features a 4.3-inch widescreen TFT display with a resolution of 480 x 272 pixels and 64,000 color depth, providing clear and readable process visualization. It incorporates a resistive touch screen alongside 4 configurable function keys for flexible operator interaction. The panel communicates via a PROFINET interface (RJ45) for integration into modern automation networks and supports the PROFINET IO protocol. It operates on a 24 V DC supply and offers a user memory of 10 MB for project data storage.
The SIMATIC KTP400 Basic is widely used in small to medium-scale machine automation across industries such as packaging, material handling, food and beverage, and general manufacturing. Its compact form factor and straightforward engineering make it suitable for machines where space is limited and basic HMI functionality is required. The panel is particularly common in standalone machine applications where a simple, cost-effective operator interface is needed without the complexity of larger panel PCs or advanced HMI systems.
Technical Specifications
| Display Size | 4.3 inch |
|---|---|
| Display Resolution | 480 x 272 pixels |
| Display Colors | 64,000 colors |
| Display Type | TFT widescreen |
| Touch Technology | Resistive touch screen |
| Function Keys | 4 configurable function keys |
| Input/Operating Voltage | 24 V DC |
| Power Consumption | 4.5 W (typical) |
| Communication Interface | PROFINET (RJ45) |
| User Memory | 10 MB |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10% to 90% (non-condensing) |
| IP/Protection Rating | IP65 (front), IP20 (rear) |
| Mounting | Panel mounting |
| Certifications | CE, UL, cULus |
| Series/Product Family | SIMATIC Basic Panel 2nd Generation |
Common Error Codes & System Events
- Event ID: 10000
- Connection to the PLC could not be established or was interrupted during runtime.
Check PROFINET cable connections and IP address configuration. Verify the PLC is powered and running. Confirm network settings in TIA Portal project match the physical setup. - Event ID: 10001
- Communication timeout between the HMI panel and the configured PLC controller.
Check network integrity and cable connections. Verify PLC program is running and not in STOP mode. Review connection parameters in the WinCC Basic project. - Event ID: 20000
- Project download failed or project data on the panel is corrupted.
Re-download the project from TIA Portal to the panel. Ensure the WinCC Basic version matches the panel firmware version. Perform a panel reset if the issue persists. - Event ID: 40000
- Panel operating system or firmware version mismatch detected.
Update the panel firmware using the ProSave tool or via TIA Portal to match the version required by the project. Ensure compatibility between TIA Portal version and panel firmware. - Event ID: 50000
- Internal panel error or hardware fault detected.
Perform a factory reset of the panel. If the fault persists after reset and re-download, the panel hardware may require repair or replacement. - Event ID: 70000
- User memory on the panel is insufficient for the loaded project.
Reduce the project size by optimizing graphics and removing unused elements. Ensure the project memory requirement does not exceed the 10 MB user memory limit of the KTP400 Basic.
Frequently Asked Questions
What communication interface does the KTP400 Basic (6AV6648-0BE11-3AX0) support?
The KTP400 Basic supports PROFINET via an RJ45 interface. It communicates with SIMATIC S7-1200 and S7-1500 PLCs using the PROFINET IO protocol configured in TIA Portal.
Which engineering software is required to configure this panel?
The panel is configured using SIMATIC WinCC Basic, which is included with TIA Portal. A standalone version of WinCC Basic or higher is required to create and download projects to this panel.
Is the KTP400 Basic compatible with S7-300 or S7-400 PLCs?
The KTP400 Basic is primarily designed for use with SIMATIC S7-1200 and S7-1500 PLCs via PROFINET. Connectivity to S7-300 or S7-400 controllers is possible via PROFINET but may have limitations; compatibility should be verified in TIA Portal.
What is the operating voltage of the 6AV6648-0BE11-3AX0?
The panel operates on 24 V DC. This supply must be within the specified tolerance range and should be provided by a suitable regulated DC power supply.
What is the front panel protection rating of this HMI?
The front of the KTP400 Basic panel is rated IP65, making it suitable for installation in control cabinet doors where protection against dust and water jets is required.
Troubleshooting
Display remains blank after power on
Measure the 24 V DC supply voltage at the panel power connector. Check that the supply is within the specified tolerance. Inspect the connector for secure contact.
Ensure the 24 V DC supply is stable and correctly connected. If the supply is confirmed good and the display remains blank, the panel backlight or internal power circuitry may be faulty and the unit should be sent for repair.
Panel shows 'No connection to PLC' message at runtime
Verify the PROFINET cable is securely connected to the RJ45 port. Check the IP address assigned to the panel and PLC in TIA Portal against the actual network configuration. Ping the PLC from a PC on the same network to confirm PLC availability.
Correct any IP address mismatches in the TIA Portal project and re-download. Replace the PROFINET cable if damaged. Ensure the PLC is in RUN mode and the PROFINET interface is active.
Touch screen does not respond or responds inaccurately
Check for physical damage or contamination on the touch screen surface. Verify that the operator is not using gloves incompatible with resistive touch technology. Check if the issue is consistent across the entire screen or localized to one area.
Clean the touch screen surface with a soft, dry cloth. Perform a touch screen calibration via the panel's Start Center settings. If calibration does not resolve the issue, the touch screen overlay may require replacement.
Project download from TIA Portal fails
Check the network connection between the engineering PC and the panel. Verify that the panel is in Transfer mode (accessible via the Start Center). Confirm that the TIA Portal version and panel firmware version are compatible.
Set the panel to Transfer mode before initiating the download. Update the panel firmware using ProSave if a version mismatch exists. Disable any firewall or antivirus software on the engineering PC that may be blocking the TIA Portal communication.
Panel repeatedly restarts or enters a boot loop
Attempt to access the Start Center during boot by pressing the touch screen when prompted. Check whether the installed project is causing the restart by performing a panel reset to factory defaults.
Perform a factory reset via the Start Center or using the ProSave tool connected via PROFINET. Re-download a verified project from TIA Portal. If the boot loop continues after reset, the panel hardware may be faulty and requires service.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6640-0CA01-0AX0 OP 73micro
€ 279,00 – € 444,13Price range: € 279,00 through € 444,13Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900
€ 875,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page