• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6647-0AC11-3AX1 KTP400 Basic
    Awaiting product image

    Siemens 6AV6647-0AC11-3AX1 KTP400 Basic

    € 455,00

    Reset
    Clear
    SKU: 6AV6647-0AC11-3AX1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6647-0AC11-3AX1 is a KTP400 Basic panel belonging to the SIMATIC HMI Basic Panel series. It is a compact 4-inch key and touch operator panel designed for simple machine-level visualization and operator control tasks. This unit is part of Siemens' entry-level HMI portfolio, offering a cost-effective solution for straightforward human-machine interface requirements.

    The KTP400 Basic features a 4-inch TFT widescreen display with a resolution of 480 x 272 pixels and 64K color depth, combined with a resistive touch screen and 4 configurable function keys for flexible operator input. It communicates via a single PROFINET interface, enabling seamless integration into modern Ethernet-based automation networks. The panel is configured using Siemens WinCC Basic (TIA Portal) engineering software and supports a project memory of 10 MB. It operates on a 24 V DC supply and is rated IP65 on the front face for protection against dust and water ingress.

    The KTP400 Basic is widely used in manufacturing, packaging, and material handling machinery where compact, cost-efficient operator panels are required. Its small form factor makes it suitable for integration into control cabinet doors or machine enclosures with limited panel space. The PROFINET connectivity ensures straightforward communication with SIMATIC S7-1200 and S7-1500 PLCs, making it a common choice for modernization projects and new machine builds across discrete manufacturing industries.

    Technical Specifications

    Display Size 4 inch
    Display Resolution 480 x 272 pixels
    Display Colors 64K (TFT)
    Touch Technology Resistive touch screen
    Function Keys 4 configurable function keys
    Input/Operating Voltage 24 V DC
    Power Consumption 4.5 W (typical)
    Communication Interface PROFINET (1x RJ45)
    Project Memory 10 MB
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90%, non-condensing
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Panel Cutout 119 x 90 mm
    Certifications CE, UL, cULus
    Engineering Software WinCC Basic (TIA Portal)
    Mounting Panel mounting

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been lost.
    Check PROFINET cable and RJ45 connector integrity. Verify IP address configuration on both the panel and PLC. Ensure the PLC is in RUN mode and the network switch or router is operational.
    Event ID: 10001
    Connection to PLC interrupted during runtime. The HMI lost communication with the configured controller.
    Inspect the PROFINET network for cable faults or switch failures. Confirm PLC is powered and running. Restart the HMI panel and re-establish the connection.
    Event ID: 20000
    Tag read error. The HMI is unable to read the value of a configured tag from the PLC.
    Verify the tag address in the WinCC project matches the actual PLC data block or memory address. Check that the PLC program has not been modified without updating the HMI project.
    Event ID: 20001
    Tag write error. The HMI is unable to write a value to the configured PLC tag.
    Confirm the PLC tag is not write-protected. Check the data type consistency between the HMI tag and the PLC variable. Re-download the HMI project if the issue persists.
    Event ID: 40000
    Project download error. A fault occurred during the transfer of the HMI project from the engineering PC to the panel.
    Ensure the correct IP address is set on the panel and engineering PC. Check that TIA Portal WinCC Basic version is compatible with the panel firmware. Retry the download after restarting both devices.
    Event ID: 50000
    System memory low. The available runtime memory on the HMI panel is insufficient to run the current project.
    Reduce the number of active screens, images, or logged data in the WinCC project. Optimize the project by removing unused tags or graphics and re-download the project.
    Event ID: 60000
    Firmware update error. The panel firmware update process failed or was interrupted.
    Restart the panel and reattempt the firmware update using ProSave or TIA Portal. Ensure the correct firmware version for the KTP400 Basic (6AV6647-0AC11-3AX1) is used and that the power supply is stable during the update.

    Frequently Asked Questions

    Which PLCs are compatible with the KTP400 Basic (6AV6647-0AC11-3AX1)?

    The KTP400 Basic communicates via PROFINET and is primarily designed for use with Siemens SIMATIC S7-1200 and S7-1500 PLCs. It can also communicate with S7-300 and S7-400 controllers that have PROFINET interfaces.

    What software is required to configure this HMI panel?

    The KTP400 Basic must be configured using Siemens TIA Portal with the WinCC Basic engineering package. Older STEP 7 or WinCC flexible software is not compatible with this panel.

    What is the display resolution and size of the 6AV6647-0AC11-3AX1?

    The panel features a 4-inch TFT widescreen display with a resolution of 480 x 272 pixels and 64K color support.

    What is the front panel protection rating of the KTP400 Basic?

    The front face of the KTP400 Basic is rated IP65, providing full protection against dust and protection against low-pressure water jets, making it suitable for industrial environments.

    Can the KTP400 Basic be used with third-party PLCs?

    The KTP400 Basic supports PROFINET communication, which in principle allows connection to third-party PROFINET-capable controllers, but Siemens officially supports and tests it with SIMATIC controllers. Compatibility with non-Siemens PLCs should be verified on a case-by-case basis.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel power connector. Check that the supply is within the specified range and that the connector is fully seated.

    Restore the 24 V DC supply to the correct voltage level. If the supply is correct but the display remains blank, the internal power supply or backlight may be faulty and the panel should be sent for repair or replacement.

    HMI panel shows 'Connecting…' and cannot establish communication with the PLC

    Verify the PROFINET cable is connected to the correct RJ45 port on the panel. Check the IP address settings on the panel via the Start Center and compare them with the configured address in the TIA Portal project.

    Correct any IP address mismatch between the panel and the TIA Portal project settings. Replace the PROFINET cable if damaged. Ensure the PLC is powered on and in RUN mode, then restart the HMI panel.

    Touch screen is unresponsive or registers incorrect touch positions

    Check the display surface for contamination, scratches, or physical damage. Attempt to recalibrate the resistive touch screen through the panel's Start Center settings menu.

    Clean the display surface with a soft, dry cloth. Perform a touch screen calibration via the Start Center. If calibration does not resolve the issue, the touch screen overlay may need to be replaced.

    HMI project cannot be downloaded from TIA Portal to the panel

    Confirm the engineering PC and the panel are on the same network subnet. Verify the panel IP address in the Start Center matches the target address configured in TIA Portal. Check for firewall software on the PC that may be blocking the connection.

    Set matching IP addresses and subnet masks on both devices. Disable any PC firewall temporarily during download. Ensure the TIA Portal WinCC Basic version is compatible with the installed panel firmware version, and update the firmware if necessary.

    Function keys do not respond when pressed

    Check the WinCC project to confirm that the function keys have been assigned events or actions in the screen configuration. Verify the project has been successfully downloaded to the panel.

    Assign the appropriate events to the function keys in the TIA Portal WinCC project and re-download the project to the panel. If keys remain unresponsive after correct configuration, the keypad membrane may be mechanically damaged and require hardware repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart