• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6646-1BA18-0AA1 SIMATIC KTP800 Basic
    Awaiting product image

    Siemens 6AV6646-1BA18-0AA1 SIMATIC KTP800 Basic

    € 775,00

    Reset
    Clear
    SKU: 6AV6646-1BA18-0AA1 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6646-1BA18-0AA1 is a SIMATIC KTP800 Basic Panel, part of the Siemens SIMATIC HMI Basic Panel family. It features an 8-inch widescreen TFT display and combines key-and-touch operation, making it a compact and versatile human-machine interface for machine-level visualization. This panel is designed for straightforward integration into Siemens automation environments and is configured using the SIMATIC WinCC Basic engineering software included with TIA Portal.

    The KTP800 Basic offers a display resolution of 800 x 480 pixels with 64,000 colors on its TFT screen, providing clear and readable process visualization. It supports PROFINET as its primary communication interface, enabling direct connection to S7-1200 and S7-1500 PLCs as well as other PROFINET-compatible controllers. The panel includes 8 configurable function keys, a resistive touch screen, 10 MB of user memory for project data, and an integrated USB interface for project transfer and data logging. Operating voltage is 24 V DC, and the unit is rated IP65 on the front face for protection against dust and water ingress.

    The SIMATIC KTP800 Basic is widely used in machine building, packaging machinery, conveyor systems, and general factory automation where a cost-effective yet reliable operator panel is required. Its compact 8-inch form factor and PROFINET connectivity make it suitable for integration into control cabinets and machine panels with limited space. The combination of touch and key operation provides flexibility for environments where gloved operation or defined key inputs are preferred.

    Technical Specifications

    Display Size 8 inch (widescreen)
    Display Resolution 800 x 480 px
    Display Colors 64,000 colors
    Display Type TFT
    Touch Technology Resistive single-touch
    Function Keys 8 configurable function keys
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 7 W
    Communication Interface PROFINET (RJ45, 10/100 Mbit/s)
    USB Interface USB 2.0 (Type A)
    User Memory 10 MB
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Panel Cutout 214 x 158 mm
    Certifications CE, UL, cULus
    Engineering Software SIMATIC WinCC Basic (TIA Portal)

    Common Error Codes and System Events

    Event ID: 10000
    Configuration error detected on startup. The project loaded on the panel contains configuration inconsistencies or is incompatible with the panel firmware version.
    Re-download the project from TIA Portal ensuring the HMI device version matches the firmware. Update firmware if necessary.
    Event ID: 10001
    Communication connection to the PLC has been lost or cannot be established.
    Check PROFINET cable connections and IP address configuration on both the panel and the PLC. Verify the PLC is in RUN mode and the network settings match the TIA Portal project.
    Event ID: 20000
    Internal device error. A system fault has been detected within the HMI panel hardware or firmware.
    Perform a power cycle. If the error persists, perform a factory reset and re-download the project. Contact Siemens support if the fault recurs.
    Event ID: 40000
    Tag read/write error. The HMI panel cannot read from or write to a configured PLC tag.
    Verify the PLC tag addresses in TIA Portal match the actual PLC program. Check that the PLC is accessible and the data block or memory area exists.
    Event ID: 50000
    Project transfer error. A project download or upload operation failed.
    Check the USB or PROFINET connection used for transfer. Ensure TIA Portal version is compatible with the panel firmware and retry the transfer.
    Event ID: 60000
    Firmware update error. The firmware update process was interrupted or failed to complete.
    Restart the firmware update procedure using the correct firmware file for the KTP800 Basic. Ensure stable power supply during the update process.
    Event ID: 70000
    Backup/restore error. A panel backup or restore operation could not be completed successfully.
    Verify the USB storage device is formatted correctly (FAT32) and has sufficient free space. Retry the backup or restore operation.

    Frequently Asked Questions

    Which PLCs are compatible with the SIMATIC KTP800 Basic 6AV6646-1BA18-0AA1?

    The KTP800 Basic is primarily designed for use with Siemens S7-1200 and S7-1500 PLCs via PROFINET. It can also communicate with S7-300 and S7-400 controllers using appropriate PROFINET connections configured in TIA Portal.

    What engineering software is required to configure this panel?

    The KTP800 Basic is configured using SIMATIC WinCC Basic, which is included with the TIA Portal engineering framework. A compatible version of TIA Portal must be used that matches the panel firmware version.

    How is the project transferred to the KTP800 Basic panel?

    Projects can be transferred to the panel via PROFINET (Ethernet) or via a USB connection using a USB Type A cable. The transfer is initiated from TIA Portal using the download function.

    What is the front protection rating of this panel?

    The front face of the KTP800 Basic is rated IP65, providing full protection against dust ingress and protection against low-pressure water jets. The rear of the panel is rated IP20.

    Can the KTP800 Basic be used with third-party PLCs?

    The KTP800 Basic is optimized for Siemens controllers and TIA Portal. Communication with third-party PLCs is not natively supported, as the panel uses Siemens-specific PROFINET protocols and TIA Portal project configuration.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC supply voltage is present at the panel power connector. Measure voltage at the terminal to confirm it is within the 20.4 V to 28.8 V DC operating range.

    Restore correct supply voltage if out of range. If voltage is correct and display remains blank, the internal power supply or backlight may have failed and the panel should be sent for repair or replacement.

    Panel cannot establish PROFINET connection to PLC

    Verify the IP address, subnet mask, and device name configured on the panel match the settings defined in the TIA Portal project. Check the physical RJ45 cable and switch/router connectivity.

    Correct any IP address or device name mismatches in TIA Portal and re-download the project. Replace the Ethernet cable if a physical fault is suspected. Ensure the PLC is powered and in RUN mode.

    Touchscreen does not respond or responds inaccurately

    Check for physical damage or contamination on the touch surface. A resistive touchscreen may require recalibration if it has been replaced or if accuracy has drifted.

    Clean the touch surface with a soft, dry cloth. Perform a touchscreen calibration via the panel's Start Center settings menu. If the touchscreen remains unresponsive, the touch overlay may need replacement.

    Project download fails with a transfer error

    Confirm that the TIA Portal version and the HMI device version in the project match the firmware installed on the physical panel. Check network connectivity or USB cable integrity.

    Update the panel firmware to match the TIA Portal project device version, or adjust the device version in the TIA Portal project to match the installed firmware. Retry the download using a known-good USB cable or stable PROFINET connection.

    Panel repeatedly reboots or freezes during operation

    Check the supply voltage for stability and ripple. Inspect the project for resource-intensive scripts or animations that may be overloading the panel processor. Review system event logs in the panel's Start Center.

    Stabilize the power supply and ensure it meets the 24 V DC specification. Optimize the HMI project by reducing update cycles and script complexity. If the issue persists after project optimization, a hardware fault may be present and the panel should be inspected.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart