• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6613-1FA51-3CA0 SIMATIC MP 277
    Awaiting product image

    Siemens 6AV6613-1FA51-3CA0 SIMATIC MP 277

    € 1.549,00

    Reset
    Clear
    SKU: 6AV6613-1FA51-3CA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6613-1FA51-3CA0 is a Multi Panel (MP 277) belonging to the SIMATIC HMI family, designed for demanding machine-level visualization and operator control tasks. This panel features a 10.4-inch TFT display and runs on the Windows CE operating system, making it suitable for complex HMI applications requiring high graphical performance. It is part of Siemens' established SIMATIC HMI panel range, which is widely deployed across industrial automation environments.

    The MP 277 10" Touch (6AV6613-1FA51-3CA0) is equipped with a resistive touchscreen interface and a 256-color TFT display with a resolution of 640 x 480 pixels (VGA). It provides multiple communication interfaces including PROFIBUS DP and MPI, as well as Ethernet (PROFINET) connectivity, enabling integration with SIMATIC S7 PLCs and third-party controllers. The panel includes 12 MB of user memory for project data, supports USB ports for peripherals and data transfer, and offers a CompactFlash card slot for extended storage. The unit operates on 24 V DC supply voltage and is rated IP65 on the front face for protection against dust and water ingress.

    The SIMATIC MP 277 is commonly used in machine building, automotive manufacturing, food and beverage processing, and packaging industries where a robust and versatile HMI solution is required at the machine level. Its multi-protocol communication capability makes it well suited for integration into both new SIMATIC-based control systems and mixed-vendor automation environments. The panel's Windows CE platform allows for the use of standard HMI software such as WinCC flexible, enabling efficient project engineering and scalability across panel families.

    Technical Specifications

    Display Size 10.4 inch
    Display Resolution 640 x 480 pixels (VGA)
    Display Colors 256 colors
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Operating System Windows CE
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 18 W
    User Memory 12 MB
    Communication Interface PROFIBUS DP/MPI, Ethernet (PROFINET), USB
    Storage Expansion CompactFlash card slot
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been lost.
    Check PROFIBUS/MPI or Ethernet cable connections and termination resistors. Verify PLC address settings match the HMI project configuration. Restart both PLC and HMI panel.
    Event ID: 10001
    Connection to PLC interrupted during runtime. The panel lost communication with the configured controller.
    Inspect network cabling for damage or loose connectors. Verify PLC is in RUN mode. Check bus termination and address conflicts on the PROFIBUS network.
    Event ID: 20000
    Project download error. Transfer of the HMI project from the engineering PC to the panel failed.
    Ensure the panel is in Transfer mode. Verify the communication interface settings in WinCC flexible match the physical connection. Check USB or Ethernet cable integrity.
    Event ID: 40000
    System memory low. Available user memory on the panel is insufficient to load or run the current project.
    Reduce project size by optimizing graphics and scripts. Delete unused project data from the panel. Consider using a CompactFlash card for extended storage.
    Event ID: 50000
    Tag read/write error. A configured process tag could not be read from or written to the PLC.
    Verify the tag address in the HMI project matches the actual PLC data block or memory area. Check PLC program for address changes. Confirm PLC is in RUN mode.
    Event ID: 60000
    Runtime software error or application crash. The WinCC flexible Runtime has encountered an unrecoverable error.
    Restart the panel. If the error persists, reload the HMI project via WinCC flexible. Check for project configuration errors such as invalid scripts or missing tag references.
    Event ID: 70000
    Hardware fault detected. An internal hardware component of the panel has reported an error condition.
    Perform a panel restart. If the fault persists after restart, the panel may require repair or replacement of the internal power supply or mainboard.

    Frequently Asked Questions

    Which communication protocols does the 6AV6613-1FA51-3CA0 support?

    The MP 277 10" Touch supports PROFIBUS DP, MPI, and PROFINET (Ethernet). It can communicate with SIMATIC S7-200, S7-300, and S7-400 PLCs as well as third-party controllers via these interfaces.

    What engineering software is required to program this HMI panel?

    The panel is configured using Siemens WinCC flexible 2008 or later. Projects are downloaded to the panel via USB, Ethernet, or MPI/PROFIBUS connection.

    What is the operating voltage of the SIMATIC MP 277?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply is capable of providing sufficient current, typically at least 1 A at 24 V DC.

    Can the CompactFlash card slot be used to expand project memory?

    Yes, the integrated CompactFlash card slot allows additional storage for project data, recipes, and data logs, extending the internal 12 MB user memory.

    Is the front panel of the MP 277 rated for wash-down or dusty environments?

    The front face of the MP 277 carries an IP65 protection rating, making it suitable for environments with dust and water spray. The rear of the panel is rated IP20.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for correct polarity. Inspect the internal fuse if accessible.

    Ensure the power supply output is within the 24 V DC tolerance range. Replace the power supply if voltage is absent or out of range. If voltage is correct and display remains blank, the backlight or internal power board may require replacement.

    Touchscreen does not respond or registers incorrect touch positions

    Check whether the touch input is consistently offset or completely unresponsive. Attempt a touchscreen recalibration via the panel's Control Panel settings in Windows CE.

    Recalibrate the touchscreen through the Windows CE Control Panel under 'Stylus' settings. If recalibration does not resolve the issue, the resistive touch overlay may be damaged and require replacement.

    HMI project cannot be transferred from engineering PC to panel

    Verify the panel is set to Transfer mode (accessible via the Start Center or Control Panel). Check the communication cable and interface settings in WinCC flexible match the physical connection type (USB, Ethernet, or MPI).

    Set the panel to Transfer mode, confirm matching interface settings in WinCC flexible, and retry the download. Replace the USB or Ethernet cable if transfer still fails. Ensure the PC firewall is not blocking the transfer on Ethernet connections.

    Panel repeatedly restarts or shows a boot loop

    Observe whether the panel reaches the Windows CE desktop or fails during the boot sequence. A corrupt project file or failed firmware update can cause boot loops.

    Boot the panel into the Service menu by holding the appropriate key combination during startup, then delete the current project or restore factory firmware. Reload the project using WinCC flexible after a successful boot.

    Communication fault alarm displayed during runtime

    Check the physical PROFIBUS or Ethernet connection between the panel and PLC. Verify the PLC is powered and in RUN mode. Confirm the bus address and baud rate settings match between the HMI project and PLC configuration.

    Reseat all communication cables and check termination resistors on the PROFIBUS network. Correct any address mismatches in the HMI project configuration. Restart both the PLC and HMI panel after making corrections.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart