Siemens 6AV6613-0AA01-1CA5 TP177A
€ 246,00
The Siemens 6AV6613-0AA01-1CA5 is a Touch Panel HMI device belonging to the SIMATIC TP177A series, part of Siemens' SIMATIC HMI family. It is a compact operator panel designed for machine-level visualization and control tasks, offering a resistive touchscreen interface in a panel-mount form factor. This unit is intended for use with Siemens WinCC flexible runtime software and is compatible with a range of Siemens PLC platforms.
The TP177A features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA), providing clear visualization of process data and operator interfaces. It supports MPI and PROFIBUS DP communication interfaces for direct integration with Siemens S7-200, S7-300, and S7-400 PLCs. The panel operates on a 24 V DC supply and includes onboard flash memory for project storage. The device is rated IP65 on the front face, making it suitable for installation in control cabinet doors exposed to dust and splash water.
The SIMATIC TP177A is widely deployed in manufacturing automation, packaging machinery, material handling systems, and process control applications. Its compact 5.7-inch form factor makes it suitable for space-constrained installations where a cost-effective, reliable operator interface is required. The panel is commonly found in industries such as automotive, food and beverage, and general machine building.
Technical Specifications
| Display Size | 5.7 inch |
|---|---|
| Display Type | STN color |
| Display Resolution | 320 x 240 pixels (QVGA) |
| Touch Technology | Resistive touchscreen |
| Input Voltage | 24 V DC |
| Communication Interface | MPI, PROFIBUS DP |
| IP Rating (Front) | IP65 |
| IP Rating (Rear) | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | -20 °C to +60 °C |
| Relative Humidity | 10 % to 90 % (non-condensing) |
| Mounting | Panel mounting |
| Series | SIMATIC TP177A |
| Certifications | CE, UL |
Common Error Codes & System Events
- Event ID: 10000
- Communication error between HMI panel and connected PLC. The panel cannot establish or maintain a connection to the configured PLC.
Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode. - Event ID: 10001
- Connection to PLC timed out. The HMI did not receive a response from the PLC within the configured timeout period.
Check physical communication wiring. Verify baud rate and station address settings on both the HMI and PLC. Reduce bus length or check for cable faults. - Event ID: 20000
- Project download error. A fault occurred during the transfer of a WinCC flexible project to the panel.
Verify the PC-to-panel communication cable is correctly connected. Ensure WinCC flexible is configured with the correct transfer settings and that the panel is in transfer mode. - Event ID: 40000
- System memory low. The available runtime memory on the panel is insufficient for the loaded project.
Reduce the complexity of the HMI project, decrease the number of active screens or logged variables. Restart the panel and reload the project. - Event ID: 50000
- Internal flash memory error. A fault was detected when reading from or writing to the internal flash storage.
Perform a factory reset of the panel and re-download the project. If the fault persists, the internal flash memory may require hardware repair or panel replacement. - Event ID: 60000
- Configuration error detected at runtime. The loaded project contains settings incompatible with the panel hardware or firmware version.
Verify the WinCC flexible project is compiled for the correct panel type and firmware version. Re-compile and re-download the project to the panel. - Event ID: 70000
- Touchscreen calibration error. The touch input is misaligned or unresponsive due to an invalid calibration state.
Access the panel's Control Panel via the Start Center and run the touchscreen calibration routine. If calibration cannot be completed, clean the touch surface and retry.
Frequently Asked Questions
Which PLCs are compatible with the SIMATIC TP177A (6AV6613-0AA01-1CA5)?
The TP177A supports communication with Siemens S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It is not natively compatible with S7-1200 or S7-1500 PLCs.
What software is used to program and configure the TP177A?
The TP177A is configured using Siemens WinCC flexible software. Projects are compiled in WinCC flexible and downloaded to the panel via a PC adapter or MPI/PROFIBUS connection.
What is the supply voltage for the 6AV6613-0AA01-1CA5?
The panel requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range to avoid damage or operational faults.
What is the front panel protection rating of the TP177A?
The front face of the TP177A is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for panel door mounting in industrial environments.
Can the TP177A display be used as a replacement for older OP/TP panels?
The TP177A can serve as a functional replacement for older SIMATIC operator panels in many applications, but the HMI project must be adapted or re-compiled in WinCC flexible to match the TP177A hardware configuration.
Troubleshooting
Display remains blank after power is applied
Check the 24 V DC supply voltage at the panel power connector. Verify polarity is correct. Inspect the internal fuse if accessible.
Ensure the power supply output is within the 24 V DC tolerance range. Replace the supply or wiring if voltage is absent or out of range. If voltage is correct and display remains blank, the backlight or internal power board may require repair.
HMI panel shows 'No connection to PLC' or communication alarm at startup
Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the PLC station address configured in the HMI project matches the actual PLC address.
Correct any wiring faults and ensure proper bus termination. Update the HMI project address settings in WinCC flexible if there is a mismatch, recompile, and re-download the project.
Touchscreen does not respond or responds inaccurately to touch input
Determine whether the issue is a calibration problem or a hardware fault by attempting to access the panel's Start Center using the touch area. Check for physical damage or contamination on the touch surface.
Run the touchscreen calibration routine from the panel's Control Panel. Clean the touch surface with a soft, dry cloth. If the touchscreen remains unresponsive after calibration, the touch overlay may require replacement.
Project download from PC to panel fails or times out
Check the PC-to-panel communication cable and adapter. Verify the panel is set to transfer mode via the Start Center. Confirm WinCC flexible transfer settings match the panel's communication interface.
Place the panel in transfer mode before initiating the download. Use a known-good MPI or PC adapter cable. If using a USB-to-MPI adapter, verify driver installation on the PC. Retry the download after correcting the configuration.
Panel restarts repeatedly or enters a boot loop
This may indicate a corrupted project file in flash memory or a hardware fault. Observe whether the panel reaches the Start Center before restarting.
If the Start Center is accessible, perform a factory reset and re-download a freshly compiled project from WinCC flexible. If the panel does not reach the Start Center, the internal flash memory or firmware may be corrupted and professional repair or firmware recovery may be required.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27
€ 755,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-8BA10-0AA0 TP177B
€ 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX1 TP177B
€ 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00Select options This product has multiple variants. The options may be chosen on the product page