• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6613-0AA01-1CA5 TP177A
    Awaiting product image

    Siemens 6AV6613-0AA01-1CA5 TP177A

    € 246,00

    Reset
    Clear
    SKU: 6AV6613-0AA01-1CA5 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6613-0AA01-1CA5 is a Touch Panel HMI device belonging to the SIMATIC TP177A series, part of Siemens' SIMATIC HMI family. It is a compact operator panel designed for machine-level visualization and control tasks, offering a resistive touchscreen interface in a panel-mount form factor. This unit is intended for use with Siemens WinCC flexible runtime software and is compatible with a range of Siemens PLC platforms.

    The TP177A features a 5.7-inch STN color display with a resolution of 320 x 240 pixels (QVGA), providing clear visualization of process data and operator interfaces. It supports MPI and PROFIBUS DP communication interfaces for direct integration with Siemens S7-200, S7-300, and S7-400 PLCs. The panel operates on a 24 V DC supply and includes onboard flash memory for project storage. The device is rated IP65 on the front face, making it suitable for installation in control cabinet doors exposed to dust and splash water.

    The SIMATIC TP177A is widely deployed in manufacturing automation, packaging machinery, material handling systems, and process control applications. Its compact 5.7-inch form factor makes it suitable for space-constrained installations where a cost-effective, reliable operator interface is required. The panel is commonly found in industries such as automotive, food and beverage, and general machine building.

    Technical Specifications

    Display Size 5.7 inch
    Display Type STN color
    Display Resolution 320 x 240 pixels (QVGA)
    Touch Technology Resistive touchscreen
    Input Voltage 24 V DC
    Communication Interface MPI, PROFIBUS DP
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    Mounting Panel mounting
    Series SIMATIC TP177A
    Certifications CE, UL

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and connected PLC. The panel cannot establish or maintain a connection to the configured PLC.
    Check MPI or PROFIBUS DP cable connections and termination resistors. Verify the PLC address settings match the HMI project configuration. Ensure the PLC is powered and in RUN mode.
    Event ID: 10001
    Connection to PLC timed out. The HMI did not receive a response from the PLC within the configured timeout period.
    Check physical communication wiring. Verify baud rate and station address settings on both the HMI and PLC. Reduce bus length or check for cable faults.
    Event ID: 20000
    Project download error. A fault occurred during the transfer of a WinCC flexible project to the panel.
    Verify the PC-to-panel communication cable is correctly connected. Ensure WinCC flexible is configured with the correct transfer settings and that the panel is in transfer mode.
    Event ID: 40000
    System memory low. The available runtime memory on the panel is insufficient for the loaded project.
    Reduce the complexity of the HMI project, decrease the number of active screens or logged variables. Restart the panel and reload the project.
    Event ID: 50000
    Internal flash memory error. A fault was detected when reading from or writing to the internal flash storage.
    Perform a factory reset of the panel and re-download the project. If the fault persists, the internal flash memory may require hardware repair or panel replacement.
    Event ID: 60000
    Configuration error detected at runtime. The loaded project contains settings incompatible with the panel hardware or firmware version.
    Verify the WinCC flexible project is compiled for the correct panel type and firmware version. Re-compile and re-download the project to the panel.
    Event ID: 70000
    Touchscreen calibration error. The touch input is misaligned or unresponsive due to an invalid calibration state.
    Access the panel's Control Panel via the Start Center and run the touchscreen calibration routine. If calibration cannot be completed, clean the touch surface and retry.

    Frequently Asked Questions

    Which PLCs are compatible with the SIMATIC TP177A (6AV6613-0AA01-1CA5)?

    The TP177A supports communication with Siemens S7-200, S7-300, and S7-400 PLCs via MPI or PROFIBUS DP interfaces. It is not natively compatible with S7-1200 or S7-1500 PLCs.

    What software is used to program and configure the TP177A?

    The TP177A is configured using Siemens WinCC flexible software. Projects are compiled in WinCC flexible and downloaded to the panel via a PC adapter or MPI/PROFIBUS connection.

    What is the supply voltage for the 6AV6613-0AA01-1CA5?

    The panel requires a 24 V DC power supply. Ensure the supply is within the specified tolerance range to avoid damage or operational faults.

    What is the front panel protection rating of the TP177A?

    The front face of the TP177A is rated IP65, providing protection against dust ingress and low-pressure water jets, making it suitable for panel door mounting in industrial environments.

    Can the TP177A display be used as a replacement for older OP/TP panels?

    The TP177A can serve as a functional replacement for older SIMATIC operator panels in many applications, but the HMI project must be adapted or re-compiled in WinCC flexible to match the TP177A hardware configuration.

    Troubleshooting

    Display remains blank after power is applied

    Check the 24 V DC supply voltage at the panel power connector. Verify polarity is correct. Inspect the internal fuse if accessible.

    Ensure the power supply output is within the 24 V DC tolerance range. Replace the supply or wiring if voltage is absent or out of range. If voltage is correct and display remains blank, the backlight or internal power board may require repair.

    HMI panel shows 'No connection to PLC' or communication alarm at startup

    Verify the MPI or PROFIBUS DP cable is correctly connected and terminated at both ends. Check that the PLC station address configured in the HMI project matches the actual PLC address.

    Correct any wiring faults and ensure proper bus termination. Update the HMI project address settings in WinCC flexible if there is a mismatch, recompile, and re-download the project.

    Touchscreen does not respond or responds inaccurately to touch input

    Determine whether the issue is a calibration problem or a hardware fault by attempting to access the panel's Start Center using the touch area. Check for physical damage or contamination on the touch surface.

    Run the touchscreen calibration routine from the panel's Control Panel. Clean the touch surface with a soft, dry cloth. If the touchscreen remains unresponsive after calibration, the touch overlay may require replacement.

    Project download from PC to panel fails or times out

    Check the PC-to-panel communication cable and adapter. Verify the panel is set to transfer mode via the Start Center. Confirm WinCC flexible transfer settings match the panel's communication interface.

    Place the panel in transfer mode before initiating the download. Use a known-good MPI or PC adapter cable. If using a USB-to-MPI adapter, verify driver installation on the PC. Retry the download after correcting the configuration.

    Panel restarts repeatedly or enters a boot loop

    This may indicate a corrupted project file in flash memory or a hardware fault. Observe whether the panel reaches the Start Center before restarting.

    If the Start Center is accessible, perform a factory reset and re-download a freshly compiled project from WinCC flexible. If the panel does not reach the Start Center, the internal flash memory or firmware may be corrupted and professional repair or firmware recovery may be required.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA10-0AA0 TP177B

      Siemens 6AV6642-8BA10-0AA0 TP177B

      € 964,00 – € 1.611,00Price range: € 964,00 through € 1.611,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX1 TP177B

      Siemens 6AV6642-0BC01-1AX1 TP177B

      € 657,00 – € 1.249,00Price range: € 657,00 through € 1.249,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart