• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6545-8BC10-0AA0 Mobile Panel 277
    Awaiting product image

    Siemens 6AV6545-8BC10-0AA0 Mobile Panel 277

    € 683,00

    Reset
    Clear
    SKU: 6AV6545-8BC10-0AA0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6545-8BC10-0AA0 is a Mobile Panel 277 belonging to the SIMATIC HMI product family. It is a portable, handheld operator panel designed for mobile machine operation and monitoring in industrial environments. This unit provides operators with full flexibility to move around a machine or plant while maintaining direct control and visualization capabilities.

    The Mobile Panel 277 features a 7.5-inch TFT color display with a resolution of 640 x 480 pixels (VGA) and supports touch screen operation. It communicates via PROFINET (Industrial Ethernet) using a trailing cable connection, and is compatible with SIMATIC WinCC flexible as its configuration software. The panel includes an integrated enabling button and emergency stop button for safety-compliant operation, and supports MPI, PROFIBUS, and Ethernet interfaces depending on configuration. It operates on 24 V DC and offers robust construction suited for demanding industrial conditions.

    The Mobile Panel 277 is widely used in automotive manufacturing, machine tool operations, press lines, and large-scale industrial machinery where operators need to move along the machine during setup, commissioning, or maintenance. Its integrated safety functions, including the enabling device and emergency stop, make it suitable for use in safety-relevant applications in accordance with applicable machinery directives. The panel is particularly valued in scenarios where stationary HMI panels cannot provide adequate visibility or access to the machine being operated.

    Technical Specifications

    Display Size 7.5 inch
    Display Resolution 640 x 480 pixels (VGA)
    Display Colors 256 colors
    Display Type TFT color LCD
    Touch Technology Resistive touchscreen
    Input/Operating Voltage 24 V DC
    Communication Interface PROFINET / Industrial Ethernet (RJ45), MPI/PROFIBUS
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front), IP54 (rear)
    Safety Features Integrated enabling button (3-position), integrated emergency stop button
    Configuration Software SIMATIC WinCC flexible 2008 or higher
    Certifications CE, UL, cULus
    Mounting Handheld / portable with trailing cable connection
    Series/Product Family SIMATIC Mobile Panel 277

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between the Mobile Panel and the connected controller. The panel cannot establish or maintain a connection to the PLC.
    Check the PROFINET or MPI/PROFIBUS cable connection and connectors. Verify the PLC is powered and running. Check network configuration and IP address settings in WinCC flexible.
    Event ID: 20000
    Project download error. The configuration project could not be transferred to the panel.
    Verify the PC and panel are on the same network subnet. Check firewall settings on the engineering PC. Retry the download via WinCC flexible Transfer function.
    Event ID: 40000
    System memory low. The panel's available runtime memory is insufficient to load the project.
    Reduce the project size by optimizing graphics and scripts. Perform a panel reset and reload the project. Check for memory leaks in scripts.
    Enabling Button Fault
    The enabling button (3-position switch) has been detected in an invalid or faulted state, preventing safe operation.
    Release and re-engage the enabling button through its full range of motion. If the fault persists, inspect the enabling button mechanism for mechanical damage and replace the panel if necessary.
    Emergency Stop Active
    The integrated emergency stop button on the Mobile Panel has been actuated, halting machine operation.
    Identify and resolve the cause of the emergency stop activation. Twist and release the emergency stop button to reset it, then acknowledge the fault in the controller before resuming operation.
    Event ID: 70000
    Panel operating system error or firmware corruption detected during startup.
    Perform a factory reset using the panel's Service menu (accessible during boot). Reload the firmware using ProSave or WinCC flexible, then re-download the project.
    Connection Timeout
    The panel has lost communication with the PLC for longer than the configured monitoring time, triggering a connection timeout.
    Check the trailing cable for damage or loose connectors. Verify the PLC program is running and the communication watchdog settings are appropriate. Reconnect the cable and acknowledge the fault.

    Frequently Asked Questions

    What communication interfaces does the Mobile Panel 277 (6AV6545-8BC10-0AA0) support?

    The Mobile Panel 277 supports PROFINET via Industrial Ethernet (RJ45) as its primary interface for controller communication, and also supports MPI and PROFIBUS connections depending on the configuration and connected controller type.

    Is the Mobile Panel 277 compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the Mobile Panel 277 is compatible with SIMATIC S7-300 and S7-400 PLCs via MPI, PROFIBUS, or PROFINET interfaces. It can also communicate with S7-1200 and S7-1500 controllers via PROFINET.

    What safety functions are integrated into the Mobile Panel 277?

    The panel includes an integrated 3-position enabling button and an emergency stop button, allowing it to be used in safety-relevant applications in compliance with machinery safety directives.

    What software is required to configure the Mobile Panel 277?

    The Mobile Panel 277 is configured using Siemens SIMATIC WinCC flexible 2008 or a later version. Projects are transferred to the panel via the Ethernet interface using the Transfer function.

    What is the display size and resolution of the 6AV6545-8BC10-0AA0?

    The display is a 7.5-inch TFT color touchscreen with a resolution of 640 x 480 pixels (VGA), supporting up to 256 colors.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the panel's power input connector. Verify the supply is within the specified range and that the cable is undamaged.

    Ensure the 24 V DC power supply is correctly connected and within tolerance. If the supply is confirmed good, perform a panel reset by holding the reset button. If the display remains blank, the internal power supply or display unit may require replacement.

    Panel cannot establish communication with the PLC

    Verify the PROFINET or MPI/PROFIBUS cable is securely connected at both ends. Check the IP address configuration on the panel matches the network settings. Use a network diagnostic tool to ping the panel from the engineering PC.

    Correct any IP address mismatches in the WinCC flexible project settings. Replace damaged cables or connectors. Ensure the PLC is in RUN mode and the communication driver is correctly configured.

    Touchscreen does not respond or responds inaccurately

    Check for physical damage or contamination on the touchscreen surface. Attempt to recalibrate the touchscreen via the panel's Control Panel settings.

    Clean the touchscreen surface with a soft, dry cloth. Recalibrate the touch input through the operating system Control Panel. If calibration does not resolve the issue, the touchscreen overlay may need to be replaced.

    Emergency stop cannot be reset after actuation

    Confirm the emergency stop button has been physically released (twisted and pulled out). Check the controller program for latched emergency stop logic that requires explicit acknowledgment.

    Fully release the emergency stop button by twisting it clockwise. Acknowledge the fault in the PLC program as required by the machine logic. If the button does not mechanically release, inspect for mechanical damage and replace the panel.

    Project download fails or times out during transfer

    Verify the engineering PC and the Mobile Panel are on the same IP subnet. Check that no firewall or antivirus software is blocking the WinCC flexible Transfer connection on port 102.

    Adjust the IP address of the PC or panel so both are on the same subnet. Disable firewall rules blocking the transfer port temporarily during download. Retry the transfer in WinCC flexible using the correct panel IP address.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      Siemens 6AV6545-8CC10-0AA0 Mobile Panel 177

      € 1.247,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart