
Siemens 6AV6520-0AA05-2AE0 SIMATIC ProTool
€ 346,00
The Siemens 6AV6520-0AA05-2AE0 is a software license for SIMATIC ProTool, Siemens' configuration and programming software for HMI (Human-Machine Interface) operator panels. Part of the SIMATIC HMI software family, this product provides the engineering environment used to create, configure, and commission visualization projects for Siemens operator panels such as the OP, TP, and MP series. It is designed to run on standard PC hardware under compatible Windows operating systems.
SIMATIC ProTool offers a project-oriented development environment with drag-and-drop screen design, tag management, alarm configuration, and recipe handling. The software supports communication with Siemens SIMATIC S5 and S7 PLCs via standard interfaces such as MPI, PROFIBUS DP, and serial connections. It includes a simulator function allowing offline testing of HMI projects without connected hardware, and supports multiple language configurations for international deployments.
SIMATIC ProTool is used across a broad range of industrial automation applications including machine tools, packaging machinery, process plants, and material handling systems. It is particularly suited for facilities already operating Siemens SIMATIC S7 or S5 controller infrastructure, where tight integration between PLC and HMI engineering environments is required. The software has been widely deployed in manufacturing and process industries where operator panel visualization is a standard requirement.
Technical Specifications
| Software Type | HMI Configuration / Engineering Software |
|---|---|
| Product Family | SIMATIC ProTool |
| Compatible HMI Devices | SIMATIC OP, TP, MP series operator panels |
| PLC Compatibility | SIMATIC S5, SIMATIC S7 |
| Communication Interfaces | MPI, PROFIBUS DP, Serial (RS-232) |
| Operating System | Windows (compatible versions per release) |
| Simulator | Integrated offline project simulator |
| Language Support | Multi-language project configuration |
| License Type | Single-user software license |
| Alarm Handling | Integrated alarm and event configuration |
| Recipe Management | Supported |
| Tag Management | Integrated tag editor |
Common Error Codes and System Events
- Event ID: 1000
- Communication error between ProTool runtime and connected PLC. Connection to the configured controller cannot be established.
Verify MPI or PROFIBUS DP cable connections and address settings. Confirm PLC is powered and in RUN mode. Check configured communication parameters in the ProTool project match the PLC settings. - Event ID: 1003
- Tag read/write error. A configured variable cannot be read from or written to the PLC.
Check that the tag address in the ProTool project matches the actual PLC data block or memory address. Verify PLC program is running and the address range is valid. - Event ID: 1010
- Project download error. Transfer of the compiled project to the operator panel failed.
Check the transfer cable connection and COM port settings. Ensure the operator panel is in transfer mode. Verify sufficient memory is available on the target device. - Event ID: 1020
- License error. Software license for ProTool is not found or has expired.
Verify the software license dongle is connected or the license is correctly installed. Use the Siemens License Manager to check license status and re-activate if necessary. - Event ID: 1030
- Compilation error in project. One or more screens or tags contain configuration errors preventing successful compilation.
Review the error log in the ProTool compiler output. Correct invalid tag references, missing screen objects, or unsupported functions for the target device type. - Event ID: 1040
- Incompatible project version. The project file was created with a different version of ProTool and cannot be opened directly.
Use the ProTool project migration function to convert the project to the current software version. Back up the original project file before migration. - Event ID: 1050
- Simulation error. The integrated simulator encountered an error and could not start the project simulation.
Check that all referenced tags and screens are correctly configured. Ensure the PC meets minimum system requirements for running the simulator. Restart ProTool and retry.
Frequently Asked Questions
Which Siemens operator panels are supported by ProTool 6AV6520-0AA05-2AE0?
This version of SIMATIC ProTool supports the configuration of Siemens SIMATIC OP (Operator Panel), TP (Touch Panel), and MP (Multi Panel) series HMI devices. Refer to the specific software release notes for the full list of supported panel types and firmware versions.
Which PLCs can be connected to HMI projects configured with ProTool?
ProTool supports communication with Siemens SIMATIC S5 and S7 series PLCs via MPI, PROFIBUS DP, and serial interfaces. Third-party PLC connectivity may be available through additional communication drivers.
Does ProTool include an offline simulator for testing projects?
Yes, SIMATIC ProTool includes an integrated simulator that allows HMI projects to be tested on a PC without requiring a physical connection to the operator panel or PLC.
Is a hardware dongle required to run SIMATIC ProTool?
Depending on the license variant, SIMATIC ProTool may require a USB or parallel port hardware license dongle. The license status can be verified and managed using the Siemens Automation License Manager.
Can ProTool projects be migrated to WinCC flexible or TIA Portal?
Siemens provides migration tools that allow ProTool projects to be converted to WinCC flexible format. Further migration to TIA Portal WinCC may require additional steps and manual rework depending on project complexity.
Troubleshooting
ProTool software fails to start after installation
Check Windows Event Viewer for application errors. Verify that the software license dongle is connected and recognized by the Siemens License Manager. Confirm the PC operating system version is compatible with this ProTool release.
Reinstall the Siemens Automation License Manager and reconnect the license dongle. If the OS is incompatible, install ProTool on a compatible Windows version, typically Windows XP or Windows 7 depending on the software release.
Project cannot be transferred to the operator panel
Verify the transfer cable is correctly connected between the PC and the operator panel's transfer port. Check that the operator panel is set to transfer mode. Confirm the correct COM port and transfer speed are selected in ProTool.
Switch the operator panel to transfer mode via its startup menu. Select the correct serial COM port in ProTool transfer settings and match the baud rate to the panel's configuration. Replace the transfer cable if communication still fails.
Communication between the operator panel and PLC is lost at runtime
Check the MPI or PROFIBUS DP cable connections at both the panel and PLC. Verify that the bus termination resistors are correctly set at both ends of the network. Confirm the PLC node address matches the address configured in the ProTool project.
Reseat all bus connectors and verify cable integrity. Ensure bus termination is active only at the physical ends of the network. Correct any address mismatches in the ProTool project and re-download to the panel.
Alarm messages are not appearing on the operator panel at runtime
Verify that the alarm tags in the ProTool project are correctly mapped to the corresponding PLC bit addresses. Check that the PLC program is correctly setting the alarm bits. Confirm the alarm view screen is configured and accessible on the panel.
Cross-check alarm tag addresses in ProTool against the PLC symbol table. Correct any address mismatches and recompile and transfer the project. Ensure the alarm display element is included on the relevant HMI screen.
ProTool project compilation fails with tag reference errors
Open the compiler output log to identify which tags or screen objects contain invalid references. Common causes include deleted tags still referenced in screens, or tag addresses outside the valid range for the target PLC type.
Use the ProTool cross-reference function to locate all uses of the invalid tags. Update or delete the invalid references, then recompile the project. Ensure all tag addresses are valid for the configured PLC and communication driver.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV3627-1QK00-2AX0 OP27
€ 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6643-0AA01-1AX1 TP277
€ 249,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page



