Siemens 6AV6520-0AA05-2AB0 SIMATIC ProTool
€ 346,00
The Siemens 6AV6520-0AA05-2AB0 is a software license for SIMATIC ProTool, Siemens' configuration software for programming and commissioning operator panels and HMI devices within the SIMATIC product family. This part number corresponds to a single-user license of ProTool, designed to run on standard engineering PCs under compatible Windows operating systems. ProTool enables engineers to create, configure, and download HMI projects to a wide range of Siemens operator panels, including the OP, TP, and MP series devices.
ProTool provides a comprehensive set of tools for designing operator interfaces, including screen editors, tag management, alarm configuration, recipe handling, and trend displays. The software supports communication with SIMATIC S5 and S7 PLCs via standard Siemens protocols such as MPI, PROFIBUS DP, and serial interfaces. It includes a simulation function that allows project testing on the engineering PC without requiring a physical HMI panel, reducing commissioning time. ProTool was a predecessor to WinCC flexible and shares a similar project structure, making migration between platforms straightforward.
ProTool is primarily used in manufacturing, process automation, and machine building environments where SIMATIC operator panels are deployed for local machine control and monitoring. It is suited for applications in automotive production lines, packaging machinery, food and beverage processing, and general factory automation. The software is particularly relevant for maintaining and extending legacy HMI installations based on older Siemens OP and TP panel generations that do not support the newer WinCC flexible or TIA Portal engineering environments.
Technical Specifications
| Software Type | HMI Configuration / Engineering Software |
|---|---|
| License Type | Single-user license |
| Product Family | SIMATIC ProTool |
| Compatible HMI Devices | SIMATIC OP, TP, MP series operator panels |
| PLC Compatibility | SIMATIC S5, SIMATIC S7 |
| Communication Protocols | MPI, PROFIBUS DP, Serial (RS-232) |
| Operating System | Windows (compatible versions per release) |
| Simulation | Integrated PC-based project simulation |
| Predecessor To | WinCC flexible |
| Installation | Single PC installation |
Common Software Error Codes
- Error 1
- License not found or invalid license key detected during software startup
Verify that the license dongle or software license is correctly installed. Use SIMATIC Automation License Manager to check license status and re-transfer if necessary. - Error 2
- Communication error between ProTool and the target HMI panel during download
Check the physical connection cable and COM port settings. Verify that the correct transfer protocol and baud rate are configured in the project settings. - Error 3
- Project compilation error due to inconsistent tag configuration
Review the tag table for duplicate addresses or unsupported data types. Correct all flagged entries and recompile the project. - Error 4
- Incompatible panel type selected for the current project
Verify that the target device selected in the project matches the physical HMI panel model. Adjust the device type in the project properties if necessary. - Error 5
- Insufficient memory on target HMI panel for project download
Reduce the number of screens, images, or recipe entries in the project. Check the panel's available memory in the transfer settings dialog. - Error 6
- Software installation failure due to missing or corrupt installation files
Re-run the installation from the original media or downloaded package. Ensure that all prerequisites and compatible Windows components are installed before retrying.
Frequently Asked Questions
Which HMI panels are compatible with SIMATIC ProTool 6AV6520-0AA05-2AB0?
ProTool is compatible with the SIMATIC OP, TP, and MP series operator panels, including devices such as the OP7, OP17, TP27, TP37, and MP270. Compatibility depends on the specific ProTool version installed.
Can ProTool projects be migrated to WinCC flexible or TIA Portal?
ProTool projects can be migrated to WinCC flexible using the integrated migration tool provided in WinCC flexible. Direct migration to TIA Portal WinCC requires an intermediate step through WinCC flexible.
What communication interfaces does ProTool support for PLC connectivity?
ProTool supports MPI, PROFIBUS DP, and serial RS-232 interfaces for communication with SIMATIC S5 and S7 PLCs, depending on the operator panel hardware being configured.
Is a hardware dongle required to run this ProTool license?
Depending on the license version, ProTool may require a hardware dongle (SIMATIC key) or a software-based license managed through the SIMATIC Automation License Manager.
On which Windows versions can ProTool be installed?
ProTool is designed for older Windows environments such as Windows 2000 and Windows XP. It is not compatible with Windows 7 or later operating systems without additional compatibility measures.
Troubleshooting
ProTool software fails to start after installation
Check the SIMATIC Automation License Manager to confirm the license is valid and properly assigned to the local PC. Verify that the installation completed without errors.
Re-transfer the license using the Automation License Manager. If the license dongle is used, ensure it is connected to the correct USB or parallel port before launching the software.
Project download to HMI panel fails with a communication error
Verify the cable connection between the PC and the HMI panel. Check that the correct COM port is selected in the transfer settings and that no other application is using the port.
Replace the PC-to-panel transfer cable if damaged. Set the correct baud rate and protocol in both ProTool transfer settings and the panel's transfer mode. Restart both the PC and the panel before retrying.
Compiled project exceeds the memory capacity of the target panel
Review the project size report generated during compilation. Identify screens with large numbers of objects, high-resolution images, or extensive recipe data that contribute to memory usage.
Optimize the project by reducing the number of graphic objects per screen, compressing or removing images, and limiting recipe entries. Consider splitting functionality across multiple screens.
ProTool does not recognize the connected HMI panel during transfer
Confirm that the panel is in transfer mode and that the correct device type is selected in the ProTool project. Check that the communication cable is the correct type for the panel model.
Set the HMI panel to transfer mode manually via its startup menu. Ensure the project's target device matches the physical panel. Use the correct Siemens PC-PPI or MPI cable as required by the panel.
Alarm messages configured in ProTool do not appear on the panel at runtime
Check that the alarm tags are correctly linked to PLC bit addresses and that the alarm classes are properly configured. Verify that the PLC program is writing to the correct memory addresses.
Review the alarm configuration in ProTool and confirm that the bit addresses match those used in the PLC program. Re-download the project after correcting any address mismatches and test with the PLC in run mode.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AG1643-0AA01-4AX0 MP 277
€ 1.278,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-0BC01-1AX0 TP177B
€ 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00Select options This product has multiple variants. The options may be chosen on the product page