• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-6BA41-3BY4 SIMATIC MP 377
    Awaiting product image

    Siemens 6AV6446-6BA41-3BY4 SIMATIC MP 377

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6446-6BA41-3BY4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-6BA41-3BY4 is a Multi Panel belonging to the SIMATIC MP 377 series, part of Siemens' SIMATIC HMI product line. This panel is a high-performance operator interface device designed for demanding industrial visualization and control tasks. It features a 15-inch widescreen TFT display and runs on the Windows CE operating system, providing a robust platform for SCADA and HMI applications.

    The MP 377 panel is equipped with a resistive touch screen and supports multiple communication interfaces including PROFIBUS DP and Ethernet (PROFINET), enabling seamless integration into modern industrial networks. It offers substantial onboard memory for project data and runtime applications, and supports USB ports for peripheral connectivity and data transfer. The unit is built to withstand harsh industrial environments, conforming to relevant IEC standards for electromagnetic compatibility and environmental protection.

    The SIMATIC MP 377 is widely deployed in manufacturing automation, process industries, and machine building applications where a large, high-resolution display and reliable network connectivity are essential. It is compatible with Siemens SIMATIC S7 PLCs and is programmed using WinCC flexible or TIA Portal engineering software. Typical installations include control panels for production lines, packaging machinery, water treatment facilities, and energy management systems.

    Technical Specifications

    Display Size 15 inch
    Display Type TFT widescreen
    Display Resolution 1024 x 768 px
    Display Colors 64,000 colors
    Touch Technology Resistive touch screen
    Operating System Windows CE 6.0
    Input Voltage 24 V DC
    Power Consumption Approx. 30 W
    Communication Interface PROFIBUS DP, Ethernet (PROFINET), USB
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Communication error between HMI panel and PLC. The configured connection to the controller cannot be established or has been lost.
    Check PROFIBUS or Ethernet cable connections and termination resistors. Verify PLC is powered and running. Confirm correct communication parameters (address, baud rate) in the HMI project configuration.
    Event ID: 10001
    Connection to PLC interrupted during runtime. The HMI panel lost communication with the configured controller.
    Inspect network cabling and connectors for damage. Check PLC CPU status. Restart the HMI panel and PLC if the connection is not automatically re-established.
    Event ID: 20000
    Tag read error. The HMI panel was unable to read a configured tag from the PLC.
    Verify the tag address in the HMI project matches the actual PLC data block or memory address. Ensure the PLC program is running and the relevant data area is accessible.
    Event ID: 20001
    Tag write error. The HMI panel was unable to write a value to the configured PLC tag.
    Check that the target PLC address is not write-protected. Verify the data type of the tag matches the PLC variable. Confirm the PLC is in RUN mode.
    Event ID: 40000
    Project loading error. The HMI runtime was unable to load the configured project file from internal memory or external storage.
    Transfer the project again using WinCC flexible or TIA Portal. Check internal flash memory for corruption. Ensure the project was compiled without errors before transfer.
    Event ID: 50000
    System memory low. Available RAM on the HMI panel is critically low, which may cause instability or application crashes.
    Reduce the number of active screens, animations, or logged tags. Restart the panel to free memory. Optimize the HMI project to reduce memory usage.
    Event ID: 60000
    Backup battery low or missing. The internal buffer battery for retaining real-time clock data is discharged or not present.
    Replace the internal lithium backup battery with the correct replacement type. Refer to the device manual for battery access procedure and correct battery specification.

    Frequently Asked Questions

    Which engineering software is used to program the SIMATIC MP 377?

    The MP 377 can be programmed using Siemens WinCC flexible 2008 or later. It is also supported in the TIA Portal via the WinCC runtime advanced option for migration projects.

    What communication protocols does the 6AV6446-6BA41-3BY4 support?

    This panel supports PROFIBUS DP and PROFINET (Ethernet) for PLC communication, as well as USB ports for peripheral devices and project transfer. Serial MPI communication may also be supported via adapter.

    Is the MP 377 compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the SIMATIC MP 377 is fully compatible with SIMATIC S7-300 and S7-400 PLCs via PROFIBUS DP or MPI, and with S7-300/400 and S7-1500 via PROFINET Ethernet.

    What is the supply voltage for the 6AV6446-6BA41-3BY4?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply is adequately rated for the panel's power consumption of approximately 30 W.

    What is the front panel protection rating of the MP 377?

    The front panel of the MP 377 achieves an IP65 protection rating when correctly installed in a panel cutout with the supplied gasket, making it suitable for environments with dust and water spray.

    Troubleshooting

    Display remains blank after power on

    Check that 24 V DC is present at the power supply connector. Measure voltage at the panel terminals. Inspect the internal fuse if accessible. Verify the power supply unit is capable of delivering sufficient current.

    Ensure the 24 V DC supply is stable and within tolerance. Replace a blown internal fuse if found. If the backlight has failed, the panel may require backlight or display replacement by a qualified repair technician.

    Touch screen does not respond or responds inaccurately

    Determine whether the issue is a complete lack of response or positional inaccuracy. Check for physical damage or contamination on the touch surface. Attempt a touch screen recalibration from the Windows CE control panel.

    Clean the touch surface with a soft, dry cloth. Recalibrate the touch screen via Start > Settings > Control Panel > Stylus in the Windows CE environment. If the touch controller hardware has failed, the touch panel assembly requires replacement.

    HMI panel cannot establish communication with the PLC

    Verify the communication cable type and wiring (PROFIBUS or Ethernet). Check that the PLC address configured in the HMI project matches the actual PLC address. Confirm the PLC is powered and in RUN mode.

    Correct any address mismatches in the WinCC flexible or TIA Portal project and retransfer. Replace damaged cables or connectors. Ensure PROFIBUS termination resistors are correctly placed at both ends of the bus segment.

    Project transfer from PC to panel fails

    Check the transfer cable or Ethernet connection between the PC and the panel. Ensure the panel is set to Transfer mode. Verify that the WinCC flexible version used is compatible with the panel firmware version.

    Switch the panel to Transfer mode via the Start Center or loader screen. Use a known-good USB or Ethernet cable. Update the panel firmware if a version mismatch is detected, following the Siemens firmware update procedure.

    Panel reboots unexpectedly or freezes during operation

    Check the 24 V DC supply for voltage dips or instability under load. Review the system event log on the panel for recorded fault events. Assess whether the issue correlates with specific HMI screen changes or tag updates.

    Stabilize the power supply and ensure adequate current capacity. Optimize the HMI project to reduce CPU load, particularly complex scripts or high-frequency tag polling. If hardware faults are suspected, return the unit for professional inspection and repair.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1643-0AA01-4AX0 MP 277

      Siemens 6AG1643-0AA01-4AX0 MP 277

      € 1.278,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart