• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-3AA40-2AY3 MP 370
    Awaiting product image

    Siemens 6AV6446-3AA40-2AY3 MP 370

    € 2.495,00

    Reset
    Clear
    SKU: 6AV6446-3AA40-2AY3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-3AA40-2AY3 is a Multi Panel (MP 370) belonging to the SIMATIC HMI Multi Panel series, designed for demanding machine-level visualization and operator control tasks. This panel is part of Siemens' established SIMATIC HMI product line and features a 12-inch TFT display, making it suitable for complex process visualization. The unit operates as a standalone HMI device capable of running WinCC flexible runtime projects.

    The MP 370 (6AV6446-3AA40-2AY3) is equipped with a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It features multiple communication interfaces including MPI/PROFIBUS DP and Ethernet (10/100 Mbit/s), enabling integration into a wide range of Siemens automation architectures. The panel runs on a Windows CE operating system, provides USB ports for peripherals and data transfer, and includes a CompactFlash card slot for project storage and data logging. It is configured and programmed using Siemens WinCC flexible engineering software.

    The MP 370 is widely deployed in machine building, automotive manufacturing, food and beverage processing, and general industrial automation environments. Its large display area and robust communication capabilities make it well suited for applications requiring detailed process overviews, recipe management, alarm logging, and trend displays. The panel is typically mounted in control cabinet doors or operator panels where a high-visibility, interactive interface is required.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 256 colors
    Touch Technology Resistive touch screen
    Operating System Windows CE
    Input/Operating Voltage 24 V DC
    Power Consumption Max. 30 W
    Communication Interface MPI/PROFIBUS DP, Ethernet 10/100 Mbit/s, RS-422/RS-485
    USB Ports 2 x USB 1.1
    Memory (User) CompactFlash card slot
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC HMI Multi Panel (MP 370)

    Common Error Codes & System Events

    Event ID: 1000
    Project transfer error — communication between the engineering PC and the panel could not be established during project download.
    Check the communication cable and interface settings. Verify the correct transfer channel (MPI, Ethernet, or USB) is selected in both WinCC flexible and the panel transfer settings.
    Event ID: 10000
    Runtime startup failure — WinCC flexible runtime could not be started on the panel.
    Check available memory on the CompactFlash card. Re-transfer the project from WinCC flexible. If the issue persists, perform a panel reset to factory defaults.
    Event ID: 20000
    PLC connection lost — the HMI panel has lost communication with the configured PLC/controller.
    Check MPI/PROFIBUS DP or Ethernet cabling and termination resistors. Verify PLC address settings match the HMI project configuration. Check PLC operating state.
    Event ID: 40000
    Tag read/write error — a configured tag could not be read from or written to the connected PLC.
    Verify the PLC data block and address referenced in the HMI project exist and are accessible. Check PLC program for address conflicts.
    Event ID: 50000
    Alarm buffer overflow — the alarm buffer on the panel has reached its maximum capacity.
    Acknowledge and clear pending alarms. Review alarm configuration in WinCC flexible to reduce alarm frequency or increase buffer size settings.
    Event ID: 70000
    Recipe data error — an error occurred during reading or writing of recipe data.
    Check the recipe configuration in WinCC flexible. Verify the CompactFlash card is properly inserted and has sufficient free space. Re-transfer the project if recipe structure has changed.
    Event ID: 110000
    System time synchronization error — the panel could not synchronize its system clock with the configured time source.
    Check the time synchronization settings in the HMI project. Verify network connectivity if NTP synchronization is configured. Set the time manually if synchronization is not required.

    Frequently Asked Questions

    What engineering software is required to program the MP 370 (6AV6446-3AA40-2AY3)?

    The MP 370 is programmed using Siemens WinCC flexible software. The project is then transferred to the panel via MPI, PROFIBUS DP, Ethernet, or USB connection.

    What communication interfaces are available on this panel?

    The 6AV6446-3AA40-2AY3 provides MPI/PROFIBUS DP (RS-422/RS-485), an Ethernet interface (10/100 Mbit/s), and USB 1.1 ports. These allow connection to SIMATIC S7 PLCs and other compatible controllers.

    Is this panel compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the MP 370 is fully compatible with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP. Ethernet-based communication with S7 PLCs using S7 protocol is also supported.

    What is the supply voltage for the 6AV6446-3AA40-2AY3?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply is adequately rated, as the panel can consume up to 30 W.

    Can the CompactFlash card be used for data logging and recipe storage?

    Yes, the CompactFlash card slot supports storage of the runtime project, data logs, alarm archives, and recipe data. The card can be removed and read on a PC using a standard CompactFlash reader.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the panel power connector. Check that the supply current is sufficient. Inspect the panel for any visible damage to the power input terminals.

    Ensure the 24 V DC supply is stable and within tolerance. If the supply is correct and the display remains blank, the internal power supply board or backlight inverter may be faulty and require replacement or professional repair.

    Panel does not respond to touch input

    Check whether the display is showing content correctly (backlight on, image visible). Attempt to navigate using any external USB mouse if connected. Determine if the issue is with the touch controller or the display itself.

    Perform a touch screen calibration via the panel's Start Center or Control Panel settings. If calibration does not resolve the issue, the resistive touch screen overlay may be damaged and require replacement.

    Cannot transfer project from WinCC flexible to the panel

    Verify the transfer mode is active on the panel (accessible via the Start Center). Check that the correct communication interface and address are configured in WinCC flexible transfer settings. Test the cable or network connection independently.

    Set the panel to transfer mode manually via the Start Center. Confirm IP address or MPI address settings match between the engineering PC and the panel. Replace the communication cable if faulty.

    HMI loses connection to PLC during operation

    Check the PROFIBUS DP or Ethernet cable connections and termination resistors on the bus. Verify the PLC is in RUN mode and the configured PLC address in the HMI project is correct. Monitor for intermittent cable faults.

    Reseat all communication connectors. Replace damaged cables. Verify PROFIBUS termination is applied only at the two physical ends of the bus. Confirm PLC address and communication parameters in the WinCC flexible project match the actual PLC configuration.

    Panel displays 'Runtime not started' or fails to load project after restart

    Check the CompactFlash card is properly seated in the slot. Attempt to access the Start Center to verify if the runtime application is listed. Check available storage space on the CompactFlash card.

    Re-seat the CompactFlash card. If the card is corrupted, re-transfer the project from WinCC flexible. If the panel repeatedly fails to start the runtime, perform a factory reset via the Start Center and re-transfer the project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-8BA12-0AB0 TP177B

      Siemens 6AV6642-8BA12-0AB0 TP177B

      € 879,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart