• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-2AA45-1BY4 SIMATIC MP 377
    Awaiting product image

    Siemens 6AV6446-2AA45-1BY4 SIMATIC MP 377

    € 5.429,00

    Reset
    Clear
    SKU: 6AV6446-2AA45-1BY4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-2AA45-1BY4 is a Multi Panel belonging to the SIMATIC MP 377 series, part of Siemens' SIMATIC HMI product family. This panel is a high-performance operator interface device designed for demanding industrial visualization and control tasks. It runs on the Windows CE operating system and is engineered for use as a standalone HMI or integrated into larger SIMATIC automation architectures.

    The MP 377 features a 15-inch TFT widescreen display with a resolution of 1024 x 768 pixels and 64,000 colors, providing clear and detailed process visualization. It supports both touch and key operation, offering flexibility in operator interaction. Communication interfaces include PROFIBUS DP, PROFINET (Ethernet), MPI, and USB ports, enabling seamless integration with SIMATIC S7 PLCs and third-party controllers. The panel is equipped with 12 MB user memory for project data and supports Siemens WinCC flexible runtime software for configuration and visualization.

    The SIMATIC MP 377 is widely deployed in manufacturing automation, process industries, and machine building applications where robust and reliable HMI solutions are required. Its compatibility with SIMATIC S7-300 and S7-400 PLCs makes it a standard choice for complex machine control panels and supervisory stations in sectors such as automotive, food and beverage, chemical processing, and water treatment.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 pixels (XGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Touch Technology Resistive touch screen
    Operating Voltage 24 V DC
    Power Consumption Max. 60 W
    Communication Interface PROFIBUS DP, PROFINET (Ethernet RJ45), MPI, USB
    User Memory 12 MB
    Operating System Windows CE 6.0
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP Rating (Front) IP65
    IP Rating (Rear) IP20
    Mounting Panel mounting
    Certifications CE, UL, cULus
    Series/Product Family SIMATIC MP 377

    Common Error Codes & System Events

    Event ID: 10000
    Connection to PLC lost or communication timeout detected between the HMI panel and the configured controller.
    Check PROFIBUS/MPI/PROFINET cabling and termination resistors. Verify PLC is powered and running. Check configured communication parameters in WinCC flexible project.
    Event ID: 10001
    Communication error on the configured connection; the controller is not responding within the expected time frame.
    Verify network address settings and baud rate configuration. Inspect cable integrity and connector seating. Restart both the HMI panel and the PLC.
    Event ID: 20000
    Project download failed or project data could not be loaded from memory.
    Re-transfer the project using WinCC flexible via USB or Ethernet. Check available user memory and ensure the project file is not corrupted.
    Event ID: 40000
    Tag value limit violation; a process tag has exceeded its configured high or low limit.
    Check the process value at the PLC. Verify tag limit configuration in the WinCC flexible project. Acknowledge the alarm on the HMI.
    Event ID: 70010
    System memory low; available runtime memory on the HMI panel is critically low.
    Reduce the number of active screens or logged data. Restart the HMI panel. Consider optimizing the WinCC flexible project to reduce memory usage.
    Event ID: 110000
    Recipe data error; recipe record could not be read or written correctly.
    Check recipe configuration in the WinCC flexible project. Verify storage media integrity. Re-transfer the project and test recipe operations.
    Event ID: 130000
    Data log error; the HMI was unable to write to the configured data log or trend buffer.
    Check available storage space on the panel or connected memory card. Verify data log configuration in WinCC flexible. Clear old log files if storage is full.

    Frequently Asked Questions

    Which PLCs are compatible with the SIMATIC MP 377?

    The MP 377 is compatible with Siemens SIMATIC S7-300, S7-400, S7-1200, and S7-1500 PLCs via MPI, PROFIBUS DP, or PROFINET. It also supports communication with third-party controllers using OPC or standard Ethernet protocols.

    What software is used to configure and program the MP 377?

    The MP 377 is configured using Siemens WinCC flexible 2008 or later. Projects are created on a PC and transferred to the panel via USB, Ethernet, or PROFIBUS.

    What is the input voltage for the 6AV6446-2AA45-1BY4?

    The panel operates on 24 V DC supply voltage. Ensure the power supply can deliver sufficient current to meet the panel's maximum power consumption of 60 W.

    Does the MP 377 support data logging and trending?

    Yes, the MP 377 supports data logging, trend displays, and alarm logging within WinCC flexible runtime. Logs can be stored in internal memory or on an external memory card.

    Can the MP 377 be used with a Compact Flash or memory card?

    Yes, the SIMATIC MP 377 includes a Compact Flash card slot that can be used for project storage, data logging, and recipe management.

    Troubleshooting

    Display remains blank after power on

    Measure 24 V DC supply voltage at the panel's power connector. Check that the supply polarity is correct and that the supply can deliver sufficient current.

    Correct any wiring or polarity issues. If supply voltage is correct and display remains blank, the internal backlight or power supply board may be faulty and require replacement.

    Touchscreen does not respond or responds inaccurately

    Check for physical damage or contamination on the touch surface. Attempt to recalibrate the touchscreen via the panel's Start Center or Control Panel settings.

    Clean the touch surface with a soft, dry cloth. Perform a touchscreen calibration from the Windows CE Control Panel. If the issue persists, the touch overlay may need to be replaced.

    HMI cannot establish communication with the PLC

    Verify the communication cable type and wiring for the selected interface (MPI, PROFIBUS, or PROFINET). Check that the HMI project settings match the PLC address and baud rate.

    Correct any wiring faults and ensure proper termination on PROFIBUS networks. Update the communication parameters in the WinCC flexible project and re-download to the panel.

    Panel freezes or restarts unexpectedly during operation

    Check the 24 V DC supply for voltage drops or ripple under load. Review the system event log in WinCC flexible for recurring event IDs indicating memory or software faults.

    Stabilize the power supply and ensure adequate current capacity. Optimize the WinCC flexible project to reduce memory load. If the issue persists, perform a factory reset and re-transfer the project.

    Project transfer via USB or Ethernet fails

    Verify that the PC running WinCC flexible and the MP 377 are on the same network subnet for Ethernet transfer. For USB, check that the correct transfer cable and driver are installed.

    Set the panel to Transfer mode via the Start Center before initiating the download. Confirm network settings and firewall exceptions on the PC. Retry the transfer using a known-good USB cable or direct Ethernet connection.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV6643-0AA01-1AX1 TP277

      Siemens 6AV6643-0AA01-1AX1 TP277

      € 249,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-0AX0 SIMATIC OP 27

      € 755,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart