• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-2AA45-0BY4 SIMATIC MP 377
    Awaiting product image

    Siemens 6AV6446-2AA45-0BY4 SIMATIC MP 377

    € 5.722,00

    Reset
    Clear
    SKU: 6AV6446-2AA45-0BY4 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-2AA45-0BY4 is a Multi Panel belonging to the SIMATIC MP 377 series, part of Siemens' SIMATIC HMI product family. This unit features a 15-inch TFT display and is designed for demanding visualization and operator control tasks in industrial automation environments. It runs on the Windows CE operating system and is configured and programmed using Siemens WinCC flexible or TIA Portal software.

    The MP 377 15" Touch features a high-resolution 1024 x 768 pixel (XGA) TFT display with 64,000 colors and resistive touch screen technology for reliable operator input. It is equipped with multiple communication interfaces including PROFIBUS DP, PROFINET (Ethernet), USB ports, and a serial RS-422/RS-485 interface, enabling integration into a wide range of automation architectures. The panel includes 12 MB user memory for project data and supports MPI/PROFIBUS communication at up to 12 Mbit/s, as well as 10/100 Mbit/s Ethernet connectivity.

    The SIMATIC MP 377 is widely deployed in machine building, process automation, and plant engineering applications where a robust, mid-to-large format HMI is required. Its compatibility with Siemens S7-300, S7-400, and S7-1500 PLC families makes it a common choice for system integrators working within the Siemens automation ecosystem. Industries such as automotive manufacturing, food and beverage processing, chemical plants, and water treatment facilities commonly utilize this panel for supervisory control and data visualization tasks.

    Technical Specifications

    Display Size 15 inch
    Display Resolution 1024 x 768 px (XGA)
    Display Colors 64,000 colors
    Display Type TFT LCD
    Touch Technology Resistive touchscreen
    Operating System Windows CE 6.0
    User Memory 12 MB
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 40 W
    Communication Interface PROFIBUS DP, PROFINET (Ethernet 10/100 Mbit/s), MPI, RS-422/RS-485, USB
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10% to 90% (non-condensing)
    IP/Protection Rating IP65 (front), IP20 (rear)
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 10000
    Project transfer error — communication between the engineering station and the panel could not be established during download.
    Check the network or PROFIBUS connection between the PC and the panel. Verify IP address or PROFIBUS address settings and ensure WinCC flexible or TIA Portal is configured for the correct interface.
    Event ID: 10001
    Project data corrupted or incompatible — the loaded project file cannot be executed by the panel runtime.
    Recompile and retransfer the project from the engineering station. Ensure the WinCC flexible or TIA Portal version matches the panel firmware version.
    Event ID: 20000
    Connection to PLC lost — the configured communication connection to the controller has been interrupted.
    Check PROFIBUS or Ethernet cabling and connectors. Verify PLC is powered and running. Check communication parameters (IP address, PROFIBUS address, rack/slot settings).
    Event ID: 20001
    Tag read/write error — a configured tag could not be read from or written to the connected PLC.
    Verify the tag address exists in the PLC program and is accessible. Check data type consistency between HMI tag configuration and PLC variable.
    Event ID: 40000
    System memory low — available runtime memory on the panel is critically low.
    Reduce the number of open screens or active alarms. Simplify the project or reduce the number of simultaneous connections. Restart the panel if necessary.
    Event ID: 50000
    Alarm buffer overflow — the alarm log has exceeded its configured maximum capacity.
    Acknowledge and clear pending alarms. Increase the alarm buffer size in the project configuration or archive alarms to external storage.
    Event ID: 70000
    Firmware update failed — an error occurred during a firmware update procedure.
    Retry the firmware update using the correct firmware file for the MP 377 15" Touch. Ensure stable power supply during the update and use the correct transfer medium (USB or Ethernet).
    Event ID: 80000
    Touchscreen calibration error — the touch input is misaligned or unresponsive.
    Perform a touchscreen recalibration via the panel's Start Center or Control Panel settings. If the issue persists, check the touchscreen connector internally or replace the touch overlay.

    Frequently Asked Questions

    What PLC families is the SIMATIC MP 377 compatible with?

    The MP 377 is compatible with Siemens S7-200, S7-300, S7-400, and S7-1500 PLC families via MPI, PROFIBUS DP, or PROFINET interfaces. It can also communicate with third-party controllers via serial protocols.

    What software is used to program the 6AV6446-2AA45-0BY4?

    This panel is programmed using Siemens WinCC flexible 2008 or later, or alternatively via the TIA Portal with the WinCC option. The project is then transferred to the panel via Ethernet, USB, or PROFIBUS.

    What is the input voltage requirement for this panel?

    The MP 377 15" Touch requires a 24 V DC power supply. Ensure the power source is stable and within the specified tolerance range to prevent runtime errors.

    Does this panel support PROFINET communication?

    Yes, the 6AV6446-2AA45-0BY4 includes an integrated PROFINET (Ethernet) interface supporting 10/100 Mbit/s, in addition to PROFIBUS DP and MPI interfaces.

    What is the front panel protection rating of the MP 377?

    The front of the panel carries an IP65 protection rating, making it suitable for installation in control cabinet doors where it may be exposed to dust and water spray. The rear of the unit is rated IP20.

    Troubleshooting

    Display remains blank after power is applied

    Measure the 24 V DC supply voltage at the panel's power connector. Check that the voltage is within tolerance. Inspect the internal fuse if accessible.

    Correct the power supply voltage if out of range. Replace a blown internal fuse with the correct rating. If the backlight has failed, the backlight unit or inverter board may need replacement.

    Touchscreen does not respond or registers incorrect input positions

    Attempt a touchscreen recalibration from the Start Center. Check whether the touch overlay is physically damaged or contaminated.

    Recalibrate the touchscreen via the Control Panel in Windows CE. Clean the screen surface. If calibration fails repeatedly, the resistive touch overlay may need to be replaced.

    Panel cannot establish communication with the PLC

    Verify the PROFIBUS address or IP address configured on the panel matches the HMI project settings. Check physical cabling and connectors on both the panel and PLC side.

    Correct any address mismatches in the project configuration and retransfer. Replace damaged cables or connectors. Ensure the PLC is in RUN mode and the communication module is functioning correctly.

    Project transfer from engineering PC fails repeatedly

    Check the transfer cable or network connection between the PC and the panel. Verify the panel is in Transfer mode via the Start Center. Confirm firewall or antivirus software is not blocking the connection.

    Set the panel to Transfer mode manually. Disable firewall rules blocking WinCC flexible communication ports. Try an alternative transfer medium such as USB if Ethernet transfer is failing.

    Panel freezes or restarts unexpectedly during operation

    Check for memory overload conditions (too many alarms, large project, many simultaneous connections). Verify the 24 V DC supply is stable and free from voltage dips.

    Optimize the project to reduce memory usage. Ensure the power supply unit is adequately rated for the panel's load. Update the panel firmware to the latest version compatible with the MP 377 series.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-2AX0 OP27

      Siemens 6AV3627-1QK00-2AX0 OP27

      € 749,00 – € 1.658,00Price range: € 749,00 through € 1.658,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart