• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-1AA41-1BB5 SIMATIC MP 370
    Awaiting product image

    Siemens 6AV6446-1AA41-1BB5 SIMATIC MP 370

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6446-1AA41-1BB5 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-1AA41-1BB5 is a Multi Panel (MP 370) belonging to the SIMATIC HMI family, designed for demanding visualization and operator control tasks in industrial automation environments. This panel features a 12-inch TFT display and is part of Siemens' high-performance Multi Panel series, which bridges the gap between standard operator panels and full PC-based systems. It is engineered to operate reliably in harsh industrial conditions and integrates seamlessly with Siemens SIMATIC controller families.

    The MP 370 (6AV6446-1AA41-1BB5) is equipped with a 12-inch TFT color display with a resolution of 800 x 600 pixels (SVGA) and supports touch screen operation. It runs on a Windows CE-based operating system and is configured using Siemens WinCC flexible engineering software. The panel provides communication interfaces including MPI, PROFIBUS DP, and Ethernet (TCP/IP), enabling flexible integration into existing automation networks. It offers onboard flash memory for project storage and supports USB ports for peripherals and data transfer. The unit operates on a 24 V DC supply and is rated to IP65 on the front face, providing protection against dust and water ingress.

    The SIMATIC MP 370 is widely deployed in machine building, automotive manufacturing, food and beverage processing, and chemical plant applications where a robust and versatile HMI solution is required. Its combination of touch operation, broad communication capability, and Windows CE platform makes it suitable for complex visualization tasks involving trend displays, alarm management, and recipe handling. The panel is particularly valued in applications requiring simultaneous connectivity to multiple controllers or integration into SCADA-level systems.

    Technical Specifications

    Display Size 12 inch
    Display Type TFT Color LCD
    Display Resolution 800 x 600 pixels (SVGA)
    Touch Technology Resistive Touch Screen
    Input/Operating Voltage 24 V DC
    Operating System Windows CE
    Communication Interface MPI, PROFIBUS DP, Ethernet (TCP/IP)
    USB Ports 2 x USB
    IP/Protection Rating IP65 (front), IP20 (rear)
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    Mounting Panel mounting
    Certifications CE, UL, cUL
    Series/Product Family SIMATIC HMI Multi Panel MP 370

    Common Error Codes & System Events

    Event ID: 1000
    Communication error to the configured controller — connection to the PLC cannot be established or has been lost.
    Check MPI/PROFIBUS or Ethernet cable connections and verify PLC address settings in the WinCC flexible project. Confirm the PLC is powered and in RUN mode.
    Event ID: 1003
    Tag read/write error — the HMI panel cannot read from or write to a configured PLC tag.
    Verify the tag address in WinCC flexible matches the actual PLC data block or memory address. Check controller program for address conflicts.
    Event ID: 10000
    Project download error — transfer of the WinCC flexible project to the panel has failed.
    Check the transfer cable or network connection. Ensure the panel is in Transfer mode and that the correct communication interface is selected in WinCC flexible Transfer settings.
    Event ID: 40000
    System memory low — available working memory on the panel is critically low.
    Reduce the size of the active project, remove unused screens or scripts, and restart the panel. Consider archiving log data to external USB storage.
    Event ID: 20000
    Recipe data error — a recipe record could not be read or written correctly.
    Check recipe configuration in WinCC flexible for correct tag assignments and data types. Verify sufficient flash memory is available on the panel.
    Event ID: 50000
    Alarm buffer overflow — the alarm log has exceeded its configured maximum capacity.
    Acknowledge and clear pending alarms. Increase the alarm buffer size in the WinCC flexible project settings or enable automatic archiving of alarm events.
    Event ID: 70000
    Screen object update error — one or more display objects on the active screen cannot be refreshed.
    Check the associated tag connections for the affected screen objects. Verify PLC communication is active and the relevant data areas are accessible.

    Frequently Asked Questions

    What engineering software is required to configure the 6AV6446-1AA41-1BB5?

    This panel is configured using Siemens WinCC flexible, which is the standard engineering tool for the SIMATIC HMI Multi Panel series. Projects created in WinCC flexible are transferred to the panel via MPI, PROFIBUS, Ethernet, or USB.

    Which Siemens PLC families are compatible with the MP 370?

    The MP 370 is compatible with SIMATIC S7-200, S7-300, S7-400, and S7-1200 controllers via MPI or PROFIBUS DP interfaces. Ethernet-based communication is also supported for compatible controller variants.

    What is the supply voltage for the 6AV6446-1AA41-1BB5?

    The panel operates on a 24 V DC supply voltage. Ensure the power supply is within the specified tolerance range to guarantee stable operation.

    Does the MP 370 support third-party PLC communication?

    Yes, the MP 370 supports communication with certain third-party controllers through configurable drivers available in WinCC flexible, including protocols such as Modbus and Allen-Bradley DF1, depending on the software version.

    What is the front panel protection rating of this unit?

    The front panel of the 6AV6446-1AA41-1BB5 is rated to IP65, providing full protection against dust ingress and resistance to low-pressure water jets, making it suitable for panel-mounted installations in industrial environments.

    Troubleshooting

    Display remains blank after power on

    Measure the 24 V DC supply voltage at the power connector on the rear of the panel. Check for blown internal fuses and inspect the power supply unit for visible damage.

    Restore the 24 V DC supply to within specification. Replace any blown fuses with the correct rating. If the internal power supply board is faulty, replace the power supply module or return the unit for repair.

    Touch screen does not respond or responds inaccurately

    Attempt to recalibrate the touch screen through the panel's Start Center or Control Panel settings. Inspect the touch screen surface for damage, contamination, or delamination.

    Perform a touch screen calibration via the Windows CE Control Panel. Clean the screen surface with a soft, lint-free cloth. If calibration fails repeatedly, the touch screen overlay may need replacement.

    Panel fails to establish communication with the PLC

    Verify the MPI or PROFIBUS address configured on the panel matches the project settings. Check the physical cable connections and termination resistors on the PROFIBUS network. Use a bus diagnostic tool to check network integrity.

    Correct any address mismatches in the WinCC flexible project and re-download to the panel. Replace damaged cables and ensure proper bus termination at both ends of the PROFIBUS segment.

    Project transfer from PC to panel fails

    Confirm the panel is set to Transfer mode via the Start Center. Check that the correct communication interface (Ethernet, MPI, or USB) is selected in WinCC flexible Transfer settings and that the PC and panel addresses are compatible.

    Switch the panel to Transfer mode manually. Verify firewall settings on the PC do not block the transfer port. Try an alternative transfer medium such as a USB memory stick if network transfer continues to fail.

    Panel reboots unexpectedly or freezes during operation

    Check the 24 V DC supply for voltage dips or ripple using an oscilloscope or multimeter. Review the alarm and system event log on the panel for recurring event IDs that may indicate software or memory issues.

    Stabilize the power supply by using a dedicated 24 V DC source with adequate current capacity. If the issue is software-related, reload the WinCC flexible project. Perform a factory reset if the panel OS is corrupted, then re-download the project.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0CC10-4AX0 SIPLUS HMI TP900

      € 1.340,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart