• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6446-1AA41-0AA3 SIMATIC MP 370
    Awaiting product image

    Siemens 6AV6446-1AA41-0AA3 SIMATIC MP 370

    € 4.076,00

    Reset
    Clear
    SKU: 6AV6446-1AA41-0AA3 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6446-1AA41-0AA3 is a Multi Panel (MP 370) belonging to the SIMATIC HMI family, designed for demanding visualization and operator control tasks in industrial automation environments. This panel features a 12-inch TFT display and is part of Siemens' high-performance Multi Panel series, which bridges the gap between standard operator panels and full PC-based systems. It is engineered to operate reliably in harsh industrial conditions and integrates seamlessly with Siemens SIMATIC controller families.

    The MP 370 (6AV6446-1AA41-0AA3) is equipped with a 12.1-inch TFT color display with a resolution of 800 x 600 pixels (SVGA), supporting up to 256 colors. The panel runs on a Windows CE operating system and is configured using WinCC flexible engineering software. It provides communication interfaces including MPI, PROFIBUS DP, and Ethernet (TCP/IP), enabling flexible integration into existing automation networks. The unit supports a touch screen input method and includes a compact flash card slot for additional memory expansion, along with USB ports for peripheral connectivity.

    The SIMATIC MP 370 is widely used in machine building, automotive manufacturing, process industries, and factory automation where a robust and versatile HMI solution is required. Its combination of a large display, multiple communication interfaces, and Windows CE-based runtime environment makes it suitable for complex visualization tasks, recipe management, trend displays, and alarm logging. The panel is commonly found on packaging machines, printing presses, conveyor systems, and process control stations.

    Technical Specifications

    Display Size 12.1 inch
    Display Resolution 800 x 600 pixels (SVGA)
    Display Colors 256 colors
    Display Type TFT color LCD
    Touch Technology Resistive touch screen
    Operating System Windows CE
    Input/Operating Voltage 24 V DC
    Power Consumption Approx. 30 W
    Communication Interface MPI, PROFIBUS DP, Ethernet (TCP/IP), RS-422/485
    Memory 12 MB user memory (expandable via CompactFlash)
    USB Ports 2 x USB 1.1
    Operating Temperature 0 °C to +50 °C
    Storage Temperature -20 °C to +60 °C
    Relative Humidity 10 % to 90 % (non-condensing)
    IP Rating (Front) IP65
    Mounting Panel mounting
    Certifications CE, UL, cULus

    Common Error Codes & System Events

    Event ID: 1000
    Configuration error detected during startup; the project loaded on the panel contains configuration inconsistencies.
    Re-transfer the project using WinCC flexible. Verify the project is compiled without errors before downloading.
    Event ID: 10000
    Communication connection to the PLC lost or could not be established.
    Check MPI/PROFIBUS/Ethernet cabling and connector integrity. Verify PLC address settings match the HMI project configuration.
    Event ID: 10001
    PLC is not responding within the configured timeout period.
    Check PLC operating state and ensure it is in RUN mode. Verify communication parameters (baud rate, station address) on both HMI and PLC.
    Event ID: 20000
    Tag read error; the HMI cannot read the configured tag address from the PLC.
    Verify the tag address exists in the PLC program and the data block is not write-protected. Check for address offset errors in the HMI project.
    Event ID: 40000
    System memory low; available runtime memory is below the critical threshold.
    Reduce the number of active screens or objects. Clear alarm logs and trend buffers. Consider expanding storage with a CompactFlash card.
    Event ID: 70010
    CompactFlash card not found or cannot be accessed.
    Reseat the CompactFlash card and ensure it is properly formatted. Replace the card if it is not recognized after reinsertion.
    Event ID: 3000
    Printer communication error; the configured printer is not responding.
    Check printer connection cable and printer power state. Verify printer driver settings in the HMI project configuration.

    Frequently Asked Questions

    What engineering software is required to configure the MP 370 (6AV6446-1AA41-0AA3)?

    The MP 370 is configured using Siemens WinCC flexible engineering software. The project is then transferred to the panel via Ethernet, MPI, or USB.

    What communication protocols does the 6AV6446-1AA41-0AA3 support?

    This panel supports MPI, PROFIBUS DP, and Ethernet (TCP/IP) for PLC communication, as well as RS-422/485 serial interfaces, allowing connection to a wide range of Siemens and third-party controllers.

    Is the MP 370 compatible with SIMATIC S7-300 and S7-400 PLCs?

    Yes, the MP 370 communicates natively with SIMATIC S7-300 and S7-400 PLCs via MPI or PROFIBUS DP, and also supports S7 communication over Ethernet.

    Can the memory on the 6AV6446-1AA41-0AA3 be expanded?

    Yes, the panel includes a CompactFlash card slot that allows memory expansion for storing additional project data, alarm logs, recipes, and trend archives.

    What is the operating voltage of the MP 370?

    The panel operates on 24 V DC, which is the standard supply voltage for SIMATIC HMI panels in industrial cabinet installations.

    Troubleshooting

    Display remains blank after power on

    Check the 24 V DC supply voltage at the power connector. Verify the internal fuse and inspect the backlight. Confirm the panel is not in screen saver mode.

    Restore the 24 V DC supply if absent. Touch the screen to wake from screen saver. If the backlight has failed, the display assembly or inverter board may need replacement.

    HMI cannot establish communication with the PLC

    Verify the cable type and wiring for MPI or PROFIBUS DP connections. Check that the station address and baud rate configured in the HMI project match the PLC settings.

    Correct any address or baud rate mismatches in WinCC flexible and re-transfer the project. Replace the communication cable if continuity testing reveals a fault.

    Touch screen does not respond accurately or is misaligned

    The touch screen calibration may have drifted. Access the Windows CE control panel to run the touch calibration utility.

    Perform a touch screen recalibration via Start > Settings > Control Panel > Stylus on the Windows CE desktop. If the issue persists, the touch overlay may require replacement.

    Project transfer fails from engineering PC to the panel

    Check the Ethernet or MPI connection between the PC and the panel. Ensure the panel is in transfer mode and the correct interface is selected in WinCC flexible transfer settings.

    Set the panel to transfer mode via the Start Center. Verify firewall settings on the engineering PC are not blocking the transfer. Try an alternative transfer cable or interface if the issue persists.

    Panel repeatedly restarts or crashes during operation

    This may indicate corrupted project data, insufficient memory, or a hardware fault. Check the event log in the Windows CE system for error entries.

    Re-transfer a freshly compiled project from WinCC flexible. Clear all logs and buffers. If the problem continues, perform a factory reset via the panel's Start Center and re-commission the device.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1642-0BD01-4AX0 TP177B

      Siemens 6AG1642-0BD01-4AX0 TP177B

      € 555,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1QK00-0AX0 OP27

      Siemens 6AV3627-1QK00-0AX0 OP27

      € 649,00 – € 869,00Price range: € 649,00 through € 869,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart