• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6382-2CA08-0AV0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6382-2CA08-0AV0 WinCC flexible 2008

    € 1.487,53

    Reset
    Clear
    SKU: 6AV6382-2CA08-0AV0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6382-2CA08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC HMI range.

    WinCC flexible 2008 offers a comprehensive engineering environment with support for a wide range of SIMATIC HMI devices, including Micro Panels, Mobile Panels, Operator Panels (OP), Touch Panels (TP), and Multi Panels (MP). The software supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, enabling integration with SIMATIC S7-200, S7-300, S7-400, and other PLC families. It includes features such as faceplates, scripting via VBScript, alarm management, trend displays, recipe management, and multi-language project support. The 2008 edition introduced enhanced usability, improved migration tools from older WinCC flexible versions, and expanded device support.

    WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is suitable for industries including automotive, food and beverage, chemical processing, and general factory automation where operator visualization and control are required. The software is typically installed on an engineering PC running a compatible Windows operating system and is used to configure, simulate, and download HMI projects to connected SIMATIC panels.

    Technical Specifications

    Software Version WinCC flexible 2008
    Product Family SIMATIC WinCC flexible
    License Type Single-user engineering license
    Supported HMI Devices Micro Panels, Mobile Panels, OP, TP, MP series
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet
    Supported PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200 (limited)
    Scripting Support VBScript
    Operating System Windows XP (SP3), Windows Vista, Windows 7
    Installation Medium DVD / electronic delivery
    Language Support Multi-language project configuration
    Simulation Integrated HMI runtime simulator
    Certifications CE

    Common Error Codes & System Events

    Error 1920
    Software license not found or invalid license key detected during startup
    Verify the license key is correctly installed using the Siemens Automation License Manager (ALM). Reinstall or transfer the license if necessary.
    Error 1722
    Installation error: Windows Installer package failure during WinCC flexible setup
    Ensure the operating system meets minimum requirements, disable antivirus during installation, and run the installer as Administrator.
    Compiler Error C1
    Project compilation failed due to inconsistent or missing tag references
    Check all tag connections in the project for missing or incorrectly linked PLC variables. Recompile after correcting tag assignments.
    Communication Error
    No connection established between engineering PC and target HMI panel during download
    Verify the communication cable and interface settings. Confirm the correct transfer channel (USB, Ethernet, or MPI/PROFIBUS) is selected in the project transfer settings.
    Runtime Error R001
    HMI runtime on the panel reports a configuration file error after project download
    Re-transfer the project ensuring the correct panel type and firmware version are selected. Update panel firmware if version mismatch is detected.
    License Expired
    Trial or time-limited license has expired, preventing project editing or compilation
    Purchase and install a valid permanent license via the Siemens Automation License Manager. Contact Siemens support for license recovery if needed.
    Migration Warning M01
    Project migrated from an older WinCC flexible version contains deprecated objects or unsupported features
    Review the migration log, update or replace deprecated objects, and revalidate all screen and tag configurations after migration.

    Frequently Asked Questions

    Which SIMATIC HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports a broad range of SIMATIC HMI devices including Micro Panels (KTP series), Mobile Panels, Operator Panels (OP 77, OP 170, OP 270, OP 277), Touch Panels (TP 177, TP 270, TP 277), and Multi Panels (MP 270, MP 370, MP 377).

    Is WinCC flexible 2008 compatible with Windows 10?

    WinCC flexible 2008 was designed for Windows XP SP3, Windows Vista, and Windows 7. It is not officially supported on Windows 10, and compatibility issues are commonly reported. For Windows 10 environments, Siemens recommends migrating to WinCC (TIA Portal).

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, Siemens provides a migration tool within TIA Portal that can import WinCC flexible 2008 projects. However, not all objects and functions migrate automatically, and manual rework is typically required after migration.

    What communication protocols does WinCC flexible 2008 support?

    WinCC flexible 2008 supports PROFIBUS DP, PROFINET IO, MPI, Ethernet TCP/IP, and serial communication protocols, enabling connectivity with a wide range of Siemens and third-party PLCs.

    Does WinCC flexible 2008 include a runtime simulator?

    Yes, WinCC flexible 2008 includes an integrated runtime simulator that allows engineers to test and validate HMI projects on the engineering PC without requiring a physical panel connection.

    Troubleshooting

    WinCC flexible 2008 fails to install on the engineering PC

    Check the Windows event log for specific installer error codes. Verify that the operating system version is Windows XP SP3, Vista, or Windows 7 and that all prerequisites such as .NET Framework and MSXML are installed.

    Run the installer as Administrator, temporarily disable antivirus and firewall software, and ensure all required Microsoft redistributables are installed before retrying the installation.

    Project cannot be downloaded to the HMI panel

    Verify the transfer channel configuration in WinCC flexible matches the physical connection (USB, Ethernet, or MPI/PROFIBUS). Check that the panel is in transfer mode and that the correct IP address or bus address is configured.

    Correct the transfer channel settings, place the panel in transfer mode manually via the panel's Start Center, and retry the download. Replace the communication cable if hardware faults are suspected.

    License Manager reports no valid license after software installation

    Open the Siemens Automation License Manager (ALM) and check whether the WinCC flexible 2008 license is listed and active. Determine if the license is stored on a USB dongle or tied to the local hard drive.

    Transfer the license to the correct storage location using ALM. If the license was lost due to a hard drive failure, contact Siemens for license recovery using the license key certificate.

    Compilation errors appear when opening a project migrated from an older WinCC flexible version

    Review the migration report generated during the import process. Identify deprecated screen objects, unsupported tag types, or removed functions that are flagged as errors.

    Replace or update all deprecated objects identified in the migration log, reassign any broken tag links, and recompile the project. Refer to the WinCC flexible 2008 migration guide for version-specific changes.

    HMI panel displays 'No connection to PLC' alarm at runtime

    Check the PLC communication settings in the WinCC flexible project, including the PLC IP address, MPI address, or PROFIBUS address. Verify that the PLC is powered and reachable on the network or bus.

    Correct the communication parameters in the project and re-download to the panel. Check network cables, switches, and PLC interface module status. Ensure the PLC program is running and the communication interface is active.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AV3607-1NH00-0AX0 OP7

      Siemens 6AV3607-1NH00-0AX0 OP7

      € 615,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX0 TP177B

      Siemens 6AG1642-0BA01-4AX0 TP177B

      € 675,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BA01-4AX1 TP177B

      Siemens 6AG1642-0BA01-4AX1 TP177B

      € 1.040,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart