• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6382-2AA08-0AX0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6382-2AA08-0AX0 WinCC flexible 2008

    € 1.416,37

    Reset
    Clear
    SKU: 6AV6382-2AA08-0AX0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6382-2AA08-0AX0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across the SIMATIC range.

    WinCC flexible 2008 offers a comprehensive engineering environment with support for a wide range of Siemens HMI hardware targets, including Micro Panels, Mobile Panels, Operator Panels, and Multi Panels. The software supports communication via PROFIBUS, PROFINET, MPI, and Ethernet interfaces, enabling integration with SIMATIC S7-200, S7-300, S7-400, and other compatible controllers. It includes features such as faceplates, scripting with VBScript, alarm management, trend displays, recipe management, and multi-language project support.

    WinCC flexible 2008 is widely used in manufacturing, process automation, machine building, and plant engineering applications. It is suitable for industries such as automotive, food and beverage, pharmaceuticals, and water treatment, where reliable HMI visualization and operator control are required. The software enables engineers to design scalable projects that can be deployed across a broad range of panel sizes and hardware generations within the SIMATIC HMI ecosystem.

    Technical Specifications

    Software Version WinCC flexible 2008
    License Type Single-user engineering license
    Supported Operating Systems Windows XP (SP2 or higher), Windows Vista, Windows 7
    Communication Interfaces PROFIBUS, PROFINET, MPI, Ethernet
    Compatible Controllers SIMATIC S7-200, S7-300, S7-400, S7-1200 (with restrictions)
    Supported HMI Targets Micro Panels, Mobile Panels, Operator Panels, Multi Panels, PC-based systems
    Scripting Support VBScript
    Language Support Multi-language project capability
    Alarm Management Included
    Recipe Management Included
    Trend Display Included
    Series/Product Family SIMATIC WinCC flexible
    Certifications CE

    Common Error Codes and System Events

    Event ID: 1000
    Project compilation error — one or more objects in the project contain configuration errors preventing successful compilation.
    Open the output window in WinCC flexible, review all listed errors, correct misconfigured objects or missing tag connections, then recompile the project.
    Event ID: 2001
    Communication connection to the PLC could not be established at runtime.
    Verify the communication interface settings (IP address, MPI address, or PROFIBUS address), check physical cabling, and confirm the PLC is in RUN mode and accessible on the network.
    Event ID: 3010
    Tag read/write error — a configured tag cannot be read from or written to the connected controller.
    Check that the tag address exists in the PLC program, verify data type compatibility between the HMI tag and PLC variable, and confirm the communication connection is active.
    Event ID: 4005
    License not found — the software cannot detect a valid license for WinCC flexible 2008.
    Insert the license dongle or transfer the license using the Automation License Manager. Verify the license matches the installed software version and edition.
    Event ID: 5020
    Runtime startup failure — WinCC flexible Runtime could not start on the target device.
    Check available memory and storage on the target panel or PC, ensure the correct runtime version is installed on the device, and re-transfer the project using the Transfer function.
    Event ID: 6001
    Project transfer error — the project could not be successfully transferred to the target HMI device.
    Verify the transfer channel settings (Ethernet IP address or serial port), ensure the target device is in Transfer mode, and check that the project is compiled without errors before initiating transfer.
    Event ID: 7015
    Alarm buffer overflow — the alarm buffer on the HMI device has reached its maximum capacity.
    Acknowledge and clear pending alarms, increase the alarm buffer size in the project settings if supported by the target hardware, and review alarm configuration to reduce unnecessary alarm triggers.

    Frequently Asked Questions

    Which Siemens HMI panels are supported by WinCC flexible 2008?

    WinCC flexible 2008 supports a wide range of SIMATIC HMI panels including Micro Panels (KTP series), Mobile Panels, Operator Panels (OP series), Multi Panels (MP series), and PC-based HMI systems. The specific panel types available depend on the edition of WinCC flexible installed.

    Is WinCC flexible 2008 compatible with SIMATIC S7-1500 controllers?

    WinCC flexible 2008 does not natively support S7-1500 controllers. For S7-1500 integration, Siemens recommends using TIA Portal with WinCC (TIA Portal) instead.

    What operating systems are supported for running WinCC flexible 2008?

    WinCC flexible 2008 supports Windows XP (SP2 or later), Windows Vista, and Windows 7. It is not officially supported on Windows 10 or Windows 11.

    Can WinCC flexible 2008 projects be migrated to TIA Portal?

    Yes, WinCC flexible 2008 projects can be migrated to TIA Portal using the integrated migration tool available in TIA Portal. Some manual rework may be required after migration depending on the complexity of the project.

    What communication protocols does WinCC flexible 2008 support?

    WinCC flexible 2008 supports communication via MPI, PROFIBUS DP, PROFINET, and Industrial Ethernet, as well as serial connections for compatible legacy controllers.

    Troubleshooting

    WinCC flexible 2008 fails to install or reports a license error during installation

    Check whether the Automation License Manager is installed and running. Verify that a valid license for WinCC flexible 2008 is present on the USB dongle or transferred to the local machine.

    Install or reinstall the Automation License Manager, insert the license dongle, and confirm the correct license is detected before launching the WinCC flexible installer again.

    Project does not compile and shows multiple errors in the output window

    Review the output window for specific error messages related to missing tags, invalid addresses, or unsupported functions for the selected target device.

    Correct all flagged configuration errors, ensure all tag addresses are valid for the connected controller type, and verify that the selected target HMI device matches the hardware being used.

    Runtime project does not start on the HMI panel after transfer

    Check that the WinCC flexible Runtime version installed on the panel matches the version used to create the project. Insufficient panel memory can also prevent startup.

    Update the panel runtime to the correct version via the Control Panel on the HMI device, free up storage space if necessary, and re-transfer the compiled project.

    No communication between the HMI panel and the PLC during runtime

    Verify the communication parameters configured in WinCC flexible (IP address, MPI node address, or PROFIBUS address) match the actual PLC settings. Check physical connections and network infrastructure.

    Correct the communication settings in the WinCC flexible project, recompile and re-transfer the project, and confirm the PLC is powered on and in RUN or STOP mode with the correct network address.

    WinCC flexible 2008 crashes or becomes unresponsive on the engineering PC

    Check the engineering PC for compatibility with the installed Windows version. Conflicts with other installed Siemens software versions or insufficient RAM can cause instability.

    Ensure the PC meets the minimum system requirements, remove conflicting software versions, apply the latest WinCC flexible 2008 service packs and patches available from Siemens support, and verify that only compatible versions of STEP 7 or other Siemens tools are installed simultaneously.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      Siemens 6AG1545-0BC15-2AX0 SIPLUS HMI TP900

      € 875,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AG1642-0BD01-2AX0 TP177B

      Siemens 6AG1642-0BD01-2AX0 TP177B

      € 714,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      Siemens 6AV3627-1NK00-2AX0 SIMATIC OP 27

      € 749,00 – € 964,00Price range: € 749,00 through € 964,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart