Siemens 6AV6381-2CB08-0AV0 WinCC flexible 2008
€ 1.995,00
The Siemens 6AV6381-2CB08-0AV0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and deploying HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI software portfolio and is used to create visualization projects for operator panels across a wide range of automation applications.
WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation using VBScript. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It provides a scalable licensing model, with this specific variant (2CB08) corresponding to a defined feature set and panel count, and includes project migration tools for upgrading from earlier WinCC flexible versions.
WinCC flexible 2008 is widely used in manufacturing, process automation, packaging machinery, and building automation industries. It is suitable for configuring operator panels such as the SIMATIC TP, OP, MP, and Mobile Panel series. The software is particularly valued in applications requiring structured visualization projects with multi-language support, centralized tag databases, and integration with SIMATIC Step 7 engineering environments.
Technical Specifications
| Software Version | WinCC flexible 2008 |
|---|---|
| License Type | Software License |
| Compatible PLC Families | SIMATIC S7-200, S7-300, S7-400, S7-1200 |
| Communication Interfaces | MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP) |
| Scripting Support | VBScript |
| Supported Panel Series | SIMATIC TP, OP, MP, Mobile Panel |
| Project Migration | Supported from earlier WinCC flexible versions |
| Operating System | Windows XP, Windows Vista, Windows 7 |
| Series/Product Family | SIMATIC WinCC flexible |
| Language Support | Multi-language project configuration |
| Alarm Logging | Supported |
| Recipe Management | Supported |
| Trend Display | Supported |
| Integration | SIMATIC STEP 7 engineering environment |
Common Error Codes & System Events
- Error 1000
- License not found or license key invalid during software startup
Verify the license key is correctly installed using the Siemens Automation License Manager (ALM). Reinstall or transfer the license if necessary. - Error 1001
- License has expired or is not valid for the installed software version
Check the license validity period and version compatibility in the Automation License Manager. Upgrade or renew the license as required. - Error 2000
- Communication connection to target panel could not be established during download
Verify the communication interface settings (MPI address, IP address, baud rate) in the project and on the target panel. Check physical cable connections and network configuration. - Error 3000
- Project compilation failed due to configuration inconsistency
Review the error log in the output window for specific tag or screen references. Correct invalid tag connections, missing resources, or unsupported object properties. - Error 4000
- Panel type mismatch between project configuration and connected hardware
Ensure the panel type selected in the project matches the physical target device. Adjust the project panel type or connect the correct hardware. - Error 5000
- Runtime transfer to panel failed or was interrupted
Check available memory on the target panel. Ensure no other transfer session is active and that the panel is in transfer mode before initiating download. - Error 6000
- Tag limit exceeded for the current license edition
Reduce the number of configured tags to within the licensed limit, or upgrade to a higher WinCC flexible license edition that supports a greater tag count.
Frequently Asked Questions
Which SIMATIC panels are supported by WinCC flexible 2008?
WinCC flexible 2008 supports the full range of SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. Compatibility depends on the specific license edition installed.
Can WinCC flexible 2008 projects be integrated with SIMATIC STEP 7?
Yes, WinCC flexible 2008 can be integrated directly into the SIMATIC STEP 7 engineering environment, allowing shared tag databases and coordinated project management between PLC and HMI configurations.
What communication protocols does WinCC flexible 2008 support?
The software supports MPI, PROFIBUS DP, and Industrial Ethernet (TCP/IP) for communication with SIMATIC S7 PLCs, as well as additional drivers for third-party controllers depending on the installed communication packages.
Is it possible to migrate older WinCC flexible projects to WinCC flexible 2008?
Yes, WinCC flexible 2008 includes project migration tools that allow projects created in earlier versions of WinCC flexible to be imported and updated to the 2008 format.
What operating systems are compatible with WinCC flexible 2008?
WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7. It is not officially supported on Windows 10 or later without additional compatibility measures.
Troubleshooting
Software fails to start and displays a license error
Open the Siemens Automation License Manager (ALM) and check whether a valid WinCC flexible 2008 license is present and assigned to the local machine.
If the license is missing or on a different machine, transfer it using the ALM tool. If the license dongle is used, ensure it is connected to the correct USB port and recognized by the system.
Project cannot be downloaded to the target panel
Check the transfer settings in WinCC flexible, including the communication interface type, IP address or MPI address, and confirm the panel is set to transfer mode.
Correct any mismatched communication parameters, ensure the panel is in transfer mode (accessible via the panel's Start Center or loader menu), and retry the download.
Compilation errors appear when building the project
Review the output window for specific error messages referencing tags, screens, or connections. Common causes include broken tag links, unsupported functions for the selected panel type, or missing image resources.
Resolve each listed error by correcting tag references, replacing unsupported objects with compatible alternatives, or re-importing missing resources, then recompile the project.
Communication between WinCC flexible runtime and PLC is lost intermittently
Check the physical network or fieldbus connection, verify the PLC communication settings match the WinCC flexible project configuration, and monitor for network load or address conflicts.
Stabilize the network connection, resolve any IP or MPI address conflicts, and adjust communication timeout parameters in the WinCC flexible connection settings if necessary.
WinCC flexible 2008 installation fails or is incomplete on the engineering PC
Check the Windows event log and the Siemens installation log for specific error codes. Verify that the PC meets the minimum hardware and operating system requirements.
Ensure the operating system is Windows XP SP3, Vista, or Windows 7 with all required updates applied. Run the installer with administrator privileges and disable antivirus software temporarily during installation.
| Condition | Repair, Used, Refurbished, New in box (sealed) |
|---|
Related products
-
Siemens 6AG1642-0BD01-4AX0 TP177B
€ 555,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV3627-1QK00-0AX0 OP27
€ 649,00 – € 869,00Price range: € 649,00 through € 869,00Select options This product has multiple variants. The options may be chosen on the product page -
Siemens 6AV6642-5AA00-0QE0 TP177B
€ 394,00Select options This product has multiple variants. The options may be chosen on the product page