• In-house repair workshop   ·   Emergency repairs   ·   New & used delivery   ·   Search & Rescue for end-of-life electronics
  • +31 513 201 218
    logo-smalllogo-smalllogo-smalllogo-small
    English
    • Dutch
    • German
    EMERGENCY REPAIR
    • Home
    • Products
      • Drive
      • HMI & Display
      • PLC
      • Power supply
      • Servo Motor
      • Products
    • Repair
      • Drives repair
        • Danfoss drives repair
        • Lenze drives repair
        • Schneider Eletric Altivar drives repair
        • Siemens Sinamics repair
      • HMI repair
        • Omron HMI repair
        • Siemens HMI repair
      • Custom repair
      • PCB repair
      • PLC-repair
      • Marine & offshore
    • Emergency repair
    • Search and Rescue
    • About us
      • Why Cirele
    • All brands
      • Allen-Bradley
      • Baumuller
      • Danfoss
      • Lenze
      • Omron
      • Schneider Electric
      • Siemens
      • Brands
    • News
    • Contact
    ✕
    • Home
    • HMI & Display
    • Siemens 6AV6381-2CB08-0AH0 WinCC flexible 2008
    Awaiting product image

    Siemens 6AV6381-2CB08-0AH0 WinCC flexible 2008

    € 1.995,00

    Reset
    Clear
    SKU: 6AV6381-2CB08-0AH0 Category: HMI & Display Brand: Siemens
    • Description
    • Additional information

    The Siemens 6AV6381-2CB08-0AH0 is a software license for WinCC flexible 2008, part of Siemens' WinCC flexible engineering software family. This product provides the runtime and configuration environment for developing and operating HMI (Human-Machine Interface) applications on Siemens panels and PC-based systems. It belongs to the SIMATIC HMI product line and is used to create visualization projects for operator panels across the SIMATIC portfolio.

    WinCC flexible 2008 offers a comprehensive set of engineering tools including tag management, alarm logging, trend displays, recipe management, and script-based automation. The software supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces. It includes a library of pre-built faceplates and symbols, supports multi-language project configuration, and is compatible with a wide range of Siemens operator panels including the TP, OP, MP, and Mobile Panel series.

    WinCC flexible 2008 is used across manufacturing, process automation, machine building, and infrastructure industries where SIMATIC HMI panels are deployed. It is particularly suited for machine-level visualization tasks where operators require real-time process data, alarm management, and recipe control. The software is commonly found in automotive production lines, packaging machinery, food and beverage processing, and water treatment facilities.

    Technical Specifications

    Software Version WinCC flexible 2008
    Product Family SIMATIC WinCC flexible
    License Type Engineering Software License
    Compatible PLC Families SIMATIC S7-200, S7-300, S7-400, S7-1200
    Communication Interfaces MPI, PROFIBUS DP, Industrial Ethernet (TCP/IP)
    Compatible HMI Panels TP, OP, MP, Mobile Panel series
    Operating System Windows XP, Windows Vista, Windows 7
    Project Languages Multi-language support
    Alarm Management Included
    Recipe Management Included
    Trend Display Included
    Script Support VB Script
    Certifications CE

    Common Error Codes & System Events

    Event ID: 1000
    Project compilation error due to inconsistent tag configuration or missing PLC connection settings.
    Review tag assignments and verify PLC connection parameters in the project settings. Recompile the project after corrections.
    Event ID: 2000
    Runtime communication error — connection to the configured PLC could not be established.
    Check physical network or PROFIBUS/MPI connections, verify PLC address settings, and confirm the communication driver is correctly configured.
    Event ID: 3000
    License not found or license key invalid for the installed WinCC flexible version.
    Verify that the correct license key is installed using the Automation License Manager. Reinstall or transfer the license if necessary.
    Event ID: 4000
    Tag limit exceeded — the number of configured tags surpasses the licensed tag count for the installed edition.
    Reduce the number of tags in the project or upgrade the license to a higher tag count edition.
    Event ID: 5000
    Download to HMI panel failed due to version mismatch between engineering software and panel firmware.
    Update the HMI panel firmware to match the WinCC flexible 2008 version using ProSave or the integrated update tool.
    Event ID: 6000
    Alarm buffer overflow — the alarm log has exceeded its configured storage capacity.
    Increase the alarm buffer size in the project settings or implement alarm archiving to an external data medium.
    Event ID: 7000
    Recipe data transfer error — recipe records could not be written to or read from the connected PLC.
    Verify recipe tag mappings, check PLC data block addresses, and confirm communication is active before retrying the transfer.

    Frequently Asked Questions

    Which SIMATIC HMI panels are compatible with WinCC flexible 2008?

    WinCC flexible 2008 supports a wide range of Siemens SIMATIC HMI panels including the TP (Touch Panel), OP (Operator Panel), MP (Multi Panel), and Mobile Panel series. Compatibility depends on the specific panel firmware version.

    Which PLCs can communicate with projects created in WinCC flexible 2008?

    WinCC flexible 2008 supports communication with SIMATIC S7-200, S7-300, S7-400, and S7-1200 PLCs via MPI, PROFIBUS DP, and Industrial Ethernet interfaces.

    What operating systems are supported for installing WinCC flexible 2008?

    WinCC flexible 2008 is compatible with Windows XP, Windows Vista, and Windows 7. It is not officially supported on Windows 10 or later without compatibility workarounds.

    Is WinCC flexible 2008 compatible with TIA Portal projects?

    WinCC flexible 2008 is not natively compatible with TIA Portal. Projects created in WinCC flexible 2008 can be migrated to TIA Portal using the integrated migration tool, but the reverse is not supported.

    Does WinCC flexible 2008 require the Automation License Manager?

    Yes, WinCC flexible 2008 uses the Siemens Automation License Manager (ALM) to manage and validate software licenses. The license must be present on the engineering PC for the software to operate.

    Troubleshooting

    WinCC flexible 2008 fails to start after installation

    Check the Automation License Manager to confirm the license is correctly installed and valid. Review Windows Event Viewer for application errors related to the WinCC flexible runtime or engineering environment.

    Reinstall the Automation License Manager and transfer the license again. Ensure the installation was performed with administrator privileges and that all required Microsoft Visual C++ redistributables are installed.

    Project cannot be downloaded to the HMI panel

    Verify the communication path between the engineering PC and the HMI panel. Check that the panel is in transfer mode and that the correct interface (Ethernet, USB, or MPI) is selected in the project transfer settings.

    Set the HMI panel to transfer mode manually, confirm IP address or MPI address settings match the project configuration, and retry the download. Update panel firmware via ProSave if a version mismatch is detected.

    Runtime communication loss between HMI panel and PLC

    Check the physical cable connections on the MPI, PROFIBUS, or Ethernet interface. Verify PLC address and network settings match those configured in the WinCC flexible project.

    Replace or reseat communication cables, confirm PLC is in RUN mode, and verify network parameters. Restart both the HMI panel and PLC if the connection does not recover automatically.

    Alarm displays are not updating on the HMI panel at runtime

    Check that the alarm tags are correctly mapped to PLC data addresses and that the PLC is actively writing to those addresses. Verify the alarm class configuration in the WinCC flexible project.

    Correct any tag address mismatches in the alarm configuration, recompile the project, and re-download to the panel. Confirm PLC logic is triggering the alarm bits as expected.

    WinCC flexible 2008 project compilation fails with tag errors

    Open the validation report generated during compilation to identify which tags have configuration errors. Common causes include duplicate tag names, invalid PLC addresses, or missing connection assignments.

    Resolve each reported tag error by correcting the address, renaming duplicate tags, or assigning the correct PLC connection. Recompile the project after all errors are addressed.

    Condition

    Repair, Used, Refurbished, New in box (sealed)

    Related products

    • Placeholder

      Siemens 6AV6642-5AA00-0QE0 TP177B

      € 394,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BC01-1AX0 TP177B

      Siemens 6AV6642-0BC01-1AX0 TP177B

      € 630,00 – € 1.421,00Price range: € 630,00 through € 1.421,00
      Select options This product has multiple variants. The options may be chosen on the product page
    • Siemens 6AV6642-0BA01-1AX1 TP177B

      Siemens 6AV6642-0BA01-1AX1 TP177B

      € 723,00 – € 2.499,00Price range: € 723,00 through € 2.499,00
      Select options This product has multiple variants. The options may be chosen on the product page

    Contact

    +31 513 201 218
    [email protected]

    CoC: 90417704
    VAT: NL865308317B01

    Location

    CirEle BV
    Röntgenweg 1
    8503 AG Joure
    The Netherlands

    General

    About us
    Shipping
    Terms and conditions
    Privacy policy
    Contact

    Repair

    Omron HMI repair
    Siemens HMI repair
    PLC repair
    Drives repair
    Request repair

    CirEle BV © 2026 | Terms and conditions | Privacy policy | Proudly powered by BOWI Marketing
      EMERGENCY REPAIR
      0

      € 0,00

      English
      • Dutch
      • English
      • German
        ✕

        Login

        Lost your password?

        Create an account?

        ✕

        Cart

        Proceed to checkout View cart
        • Shop
        • My account
        • 0 Cart